HST 500J Touch Screen Low-temperature Automatic Impact Testing Machine(RT to -80℃) JBDS-500Y-80
3.Specifications
Model |
HST JBDS-500Y-80 |
||||
Energy display mode |
with dial gauge and touch screen |
||||
Max. impact energy |
500J |
||||
Impact Energy |
250J |
500J |
|||
Value Of Every Grid |
2.5J |
5J |
|||
Moment Of Pendulum |
133.9746N.m |
267.9492N.m |
|||
Distance between pendulum shaft and impact point |
800mm |
||||
Impact speed |
5.4m/s |
||||
Raised angle |
150° |
||||
Standard span |
40+0.2mm |
||||
Round angle of the jaw |
R1-1.5mm |
||||
Round angle of impact edge |
R2-2.5,R8±0.05mm |
||||
Angle accuracy |
0.1° |
||||
Standard specimen dimension |
10×10(7.5/5)×55mm |
||||
Thickness of impact knife |
16mm |
||||
Dip angle of supporting surface of supports |
11°±1° |
||||
Impact edge Angle |
30°±1° |
||||
Impact edge curvature radius |
2mm impact edge |
2-2.5 |
|||
8mm impact blade |
8±0.05 |
||||
8mm impact shoulder Angle radius |
0.1-1 |
||||
8mm impact blade width |
4 ±0.05 |
||||
Impact blade width |
10-18mm |
||||
Impact knife thickness |
16mm |
||||
Meet the sample size |
10×10x55 mm |
||||
Refrigeration mode |
Compressor |
||||
Refrigerating medium |
Freon |
||||
Capacity of sample box |
Standard 20 |
||||
Temperature control range |
room tempeature~-80°c |
||||
Constant temperature accuracy |
fluctuation ±0.5°C grades 1°C |
||||
Sample delivery method |
pneumatic |
||||
Sample delivery positioning time |
≤4S |
||||
Positioning mode |
pneumatic |
||||
Positioning accuracy |
0.1 mm |
||||
Pneumatic pressure |
0.3 to 0.7MPa |
||||
Angle measurement |
photoelectric encoder |
||||
Angle accuracy |
0.1° |
||||
Dial energy resolution |
≥0.5J |
||||
computer screen display energy resolution |
0.01J |
||||
Mainframe Overall dimensions |
2100×600×1450mm |
||||
Low-temperature system |
1100x1000x500mm |
||||
Electrical cabinet |
960×620×830mm |
||||
Weight |
800Kg |
||||
Power supply |
3-phase 380V± 10%, 50Hz |
||||
Measurement and control part description:
50N-5KN Single Column Universal Testing Machine |
Electronic Universal Testing Machine with 10kN Pneumatic Grips |
Electronic Universal Testing Machine with Hydraulic grips |
Electronic Universal Testing Machine with Temperature Chamber |
50kN -1000kN Hydraulic Dynamic Static Fatigue Testing Machine |
100kN -2000kN Servo Hydraulic Universal Testing Machine |
Send Inquiry to This Supplier
You May Also Like
-
HST 500J Pendulum Laboratory Impact Tester Digital Test Machine Pendulum Impact Testing MachineUS$ 45486.35 - 48985.30MOQ: 1 Set
-
HST JB-300B Impact Testing Machine 300J Charpy Pendulum Impact Testing MachineUS$ 27991.60 - 31490.55MOQ: 1 Set
-
HST-DIT302E 300J Composite Plate Drop Weight Impact TesterUS$ 40000 - 50000MOQ: 1 Set
-
HST-DIT302E 300J Composite Plate Drop Weight Impact TesterUS$ 40000 - 50000MOQ: 1 Set
-
HST-DIT302E ASTM D 7136/D 7136M Composite Plate Drop Weight Impact Testing MachineUS$ 40000 - 50000MOQ: 1 Set
-
HST DWC-40 Charpy Impact Test Cooling Low Temperature Chamber Impact Sample FreezerUS$ 27291.81 - 29391.18MOQ: 1 Set
-
HST DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test Cooling Chamber Chiller Cooling BathUS$ 27291.81 - 29391.18MOQ: 1 Set
-
HST Manufacturers Manual Impact Testing Machine 220V Frames Impact Testing Tool With 1-Year WarrantyUS$ 999 - 8999MOQ: 1 Set
-
HST Manual 300/500/750 KN ASTM E23 Notch Broaching Charpy Impact Testing MachineUS$ 999 - 8999MOQ: 1 Set
-
YES 2000EG HST Model Semi-Automatic Pendulum Impact Testing Machine 220V 1-Year WarrantyUS$ 1500 - 3100MOQ: 1 Set