Home > Electrical & Electronics > Optical Fiber, Cable & Wire > Electric Wire & Cable > Industrial Heating Cable for Freeze Protection of Water Lines - Medium Temp, Self-Regulating

Industrial Heating Cable for Freeze Protection of Water Lines - Medium Temp, Self-Regulating

Industrial Heating Cable for Freeze Protection of Water Lines - Medium Temp, Self-Regulating photo-1
Industrial Heating Cable for Freeze Protection of Water Lines - Medium Temp, Self-Regulating photo-2
Industrial Heating Cable for Freeze Protection of Water Lines - Medium Temp, Self-Regulating photo-3
Industrial Heating Cable for Freeze Protection of Water Lines - Medium Temp, Self-Regulating photo-4
Industrial Heating Cable for Freeze Protection of Water Lines - Medium Temp, Self-Regulating photo-5
Negotiable MOQ: 50 Meters (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Application:
Other, Water lines freeze protection
Certification:
Other, UL/cUL listed
Model:
Medium Temperature Self-Regulating
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Application Other, Water lines freeze protection
Certification Other, UL/cUL listed
Model Medium Temperature Self-Regulating
Material Nickel-plated copper bus wires
Voltage Rating 120V or 240V
Maximum Exposure Temperature 150°F (65°C)
Minimum Installation Temperature -40°F (-40°C)
Power Output 10W/ft at 50°F (10W/m at 10°C)
Thermal Cutoff Optional

Prevent costly pipe freezing and bursting with our Industrial Self-Regulating Heating Cable designed specifically for water lines in commercial and industrial settings. This medium-temperature cable automatically adjusts its heat output based on surrounding conditions, delivering reliable freeze protection while minimizing energy consumption. Engineered for demanding environments, it maintains consistent thermal performance even in sub-zero temperatures down to -40°F (-40°C).

The cable's intelligent self-regulating technology eliminates overheating risks and reduces operational costs by up to 60% compared to constant-wattage alternatives. Its robust construction features nickel-plated copper bus wires and radiation-crosslinked conductive core that ensure long-term reliability in corrosive environments. With UL/cUL certification, this solution meets stringent safety standards for industrial applications.

Key technical specifications:

Power Output 10W/ft at 50°F (10W/m at 10°C)
Voltage Options 120V or 240V AC
Temperature Range -40°F to 150°F (-40°C to 65°C)
Maximum Circuit Length 330 ft (100m) at 120V
Insulation Material Fluoropolymer

Installation Advantages:

  • Overlappable design allows direct contact without overheating
  • Maintains flexibility at -40°F for cold-weather installation
  • Cut-to-length functionality reduces material waste
  • Optional thermal cutoff provides additional safety layer

This heating cable delivers three critical operational benefits for facility managers: First, it prevents ice blockages that disrupt water supply systems. Second, it eliminates pipe repair costs from freeze damage. Third, it reduces insurance premiums by mitigating freeze-related risks. The self-regulating core automatically increases power in cold spots while reducing output in warmer areas, ensuring uniform protection along the entire pipeline.

Common applications include: Fire sprinkler systems, industrial process piping, rooftop downspouts, water treatment facilities, and exterior hydrant lines. The cable maintains consistent performance when buried underground or exposed to UV radiation, making it suitable for both indoor and outdoor installations.

FAQ Section:

Q: Can this cable be used on plastic pipes?

A: Yes, when installed with proper temperature controllers. The self-regulating feature prevents overheating on plastic materials.

Q: How does it handle power fluctuations?

A: The conductive core automatically compensates for voltage variations between 90-280V, maintaining stable operation.

Q: Is professional installation required?

A: While designed for ease of installation, we recommend certified electricians for industrial applications.

Q: What maintenance is needed?

A: The system requires annual inspection of connections and thermal insulation. The cable itself is maintenance-free.

Q: Can it be used in hazardous locations?

A: Standard version is for non-hazardous areas. Hazardous location models are available upon request.

Upgrade your freeze protection system with this energy-efficient solution that combines intelligent thermal regulation with industrial-grade durability. Contact our engineering team at Shandong Huaning for custom length configurations and project-specific installation guidance. Protect your critical water infrastructure year-round with reliable performance that reduces operational costs and prevents catastrophic pipe failures.