Key Specifications
Get Latest Price
I/O Number:
Schneider 140CPU67060
Place of Origin:
America
Model Number:
Schneider 140CPU67060
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
I/O Number Schneider 140CPU67060
Place of Origin America
Model Number Schneider 140CPU67060
Condition NEW
Warranty One Year
Package Original Packaging
HS Code 853710
Why This Module Stays Ahead When It Counts
  • True Hot Standby Redundancy – Unlike cold standby systems, both CPUs run in parallel. If your primary processor glitches during a midnight shift (as they sometimes do with voltage spikes), the backup takes over before your safety interlocks even register a hiccup.

  • Quantum Ecosystem Compatibility – Plugs straight into existing Modicon Quantum racks. You won't need to rewrite ladder logic or replace I/O modules – a huge win if you're upgrading legacy systems on a tight budget.

  • Field-Tested Ruggedness – From my experience troubleshooting Gulf Coast refineries, the conformal coating handles humidity and dust way better than standard industrial CPUs. One client in a paper mill ran it for 18 months straight without cleaning – not something I'd recommend, but it tells you about the build quality.

  • Real-Time Diagnostics – The status LEDs actually mean something (unlike some brands). A slow blink on CHF? Probably just a comms glitch. Rapid flashing? Time to check your fiber optic links before it escalates.

Technical Reality Check
SpecificationDetails
Brand/ModelSchneider Electric 140CPU67060
HS Code8537.10.00 (Programmable controllers)
Power Requirements24V DC ±15%, 2.5A max per CPU (requires dual isolated power supplies for redundancy)
Operating Temp-25°C to +70°C (tested to maintain sync at 65°C ambient – crucial for cramped control cabinets)
Comm InterfacesDual Ethernet (Modbus TCP), Profibus DP-V1, and dedicated fiber optic port for CPU sync (500m max distance)
InstallationDIN rail (IEC 60715), requires 100mm clearance above/below for thermal management
Where You'll Actually Need This

If you're automating processes where failure means environmental spills or safety shutdowns, this isn't optional. Think water treatment plants keeping chlorine injection running during grid fluctuations, or pharmaceutical cleanrooms maintaining sterile conditions during compressor failures. One refinery client told me their old system took 45 seconds to reboot after a power dip – with the 140CPU67060, they've had zero process interruptions in 11 months. It's overkill for a conveyor belt, but for critical path processes? Non-negotiable.

D1F2A77952A7729F5FB225D562FE4249

The Procurement Perspective

Let's talk numbers: yes, it costs 30% more than a single CPU setup. But when your downtime costs $12k/hour (like that semiconductor fab I visited last quarter), the ROI hits in under 8 months. You'll also save on integration headaches – it speaks native Quantum language, so your maintenance team won't need retraining. And from my experience, Schneider's local tech support actually answers calls within 20 minutes during critical outages, which matters more than spec sheet promises.

Keeping It Running Smoothly

Mount it in a NEMA 4X cabinet with forced ventilation if ambient temps exceed 55°C – I've seen sync failures from overheating in unventilated panels. Always use shielded twisted-pair for the sync fiber (yes, it matters). For maintenance: quarterly firmware checks (Schneider pushes security patches quietly), and wipe vents with an anti-static cloth monthly. Pro tip: label both CPUs as "Primary/Backup" – saves confusion during midnight troubleshooting.

Certifications & Peace of Mind

CE, UL 61131-2, and RoHS certified – no customs headaches. The 365-day warranty covers field failures (not lightning strikes, obviously), and here's what most vendors won't tell you: if you order with us, we include free firmware validation before shipping. Stock units ship in 1 week; custom-configured takes up to 4 weeks. Payment's 50% upfront (we get it – cash flow's tight everywhere), balance before FedEx/UPS/DHL dispatch. One client last month needed it for a nuclear plant outage – we had it on site in 8 days with DHL Express.

Product Tags: Schneider Electric 140CPU67060 , 140CPU67060

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
1Yr
Business Type
Trading Company
Year Established
2014
Annual Export Value
US$2.5 Million - US$5 Million
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs