HCR-115 Differential Scanning Calorimeter Introduction
Thermal analysis of the classical differential scanning calorimetry as a heat effect of the temperature-controllable program, In today's all kinds of materials and chemistry research and development, process optimization, quality control and quality for all occasions, such as failure analysis has long been widely used. By DSC method, we can study the phase transition of the inorganic material, the solid/liquid ratio of polymer melt crystallization process, the drug polymorphs, grease and other food and the like.
HCR-115 Differential Scanning Calorimeter Features
1. Heat type differential scanning calorimeter repeatability, accuracy, particularly suitable for precise measurements of the specific heat.
2. Two perfect atmosphere control system that uses mass flow controllers.
3. Equipped with standard material, with calibration function, the user may correct temperature and heat enthalpy, to reduce the error of the instrument.
4. The user the calculation formula and calculation method, our factory can provide the corresponding software development products.
5. Intelligent software design, fully automatic drawing instrument, the software can achieve a variety of data processing, such as enthalpy calculations, the glass transition temperature, the oxidation induction period and the melting point of the crystalline material and the like.
6. DSC instrument can automatically generate test reports and oxidation induction period.
7. large screen LCD display, real-time display of instrument status and data, two sets of temperature measuring thermocouples, one set displaying sample temperature during operation, and the other set displaying furnace temperature in real-time.
HCR-115 Differential Scanning Calorimeter Features Specifications
Temperature Parameter | |
Temperature range | Room temperature ~1150℃ (air-cooled) |
Control Mode | Rising temperature, constant temperature (fully automatic control) |
Curve scanning | Rising scan |
Heating rate | 1℃/min~80℃/min |
Temperature resolution | 0.1℃ |
DSC Parameter | |
DSC range | 0~+500mW |
DSC resolution | 0.01μw |
DSC accuracy | 0.1μw |
Atmosphere control | Embedded digital flow meter (MFC) &Software control |
Gas flow | 10~200mL/min |
Sample Pan | |
Aluminum 0.06mL Platinum 0.06mL Sealed aluminum crucible 30 μ L | |
Send Inquiry to This Supplier
You May Also Like
-
STA-115 Simultaneous Thermal AnalyzerUS$ 10000 - 50000MOQ: 1 Set
-
STA-115 Simultaneous Thermal Analyzer PriceUS$ 10000 - 50000MOQ: 1 Set
-
STA-115 Simultaneous Thermal Analyzer STAUS$ 10000 - 50000MOQ: 1 Set
-
STA-115 Simultaneous Thermal AnalyserUS$ 10000 - 50000MOQ: 1 Set
-
STA-115 Simultaneous Thermal AnalysisUS$ 10000 - 50000MOQ: 1 Set
-
STA-115 Simultaneous Thermal Analysis PDFUS$ 10000 - 50000MOQ: 1 Set
-
STA-115 Thermal Analysis InstrumentsUS$ 10000 - 50000MOQ: 1 Set
-
STA-125 Thermal Analysis Instruments ManufacturerUS$ 10000 - 50000MOQ: 1 Set
-
STA-125 Simultaneous ThermogravimetryUS$ 10000 - 50000MOQ: 1 Set
-
STA-125 Simultaneous Thermogravimetry (STA/TGA-DSC)US$ 10000 - 50000MOQ: 1 Set