Home > Electrical & Electronics > Sensor > Pressure Sensor > 0-5A Input Single Phase ac Current Transducer With 4-20mA Output BD-AI

0-5A Input Single Phase ac Current Transducer With 4-20mA Output BD-AI

0-5A Input Single Phase ac Current Transducer With 4-20mA Output BD-AI photo-1
0-5A Input Single Phase ac Current Transducer With 4-20mA Output BD-AI photo-2
0-5A Input Single Phase ac Current Transducer With 4-20mA Output BD-AI photo-3
0-5A Input Single Phase ac Current Transducer With 4-20mA Output BD-AI photo-4
0-5A Input Single Phase ac Current Transducer With 4-20mA Output BD-AI photo-5
US$ 37.1 - 37.1 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
Acrel
Place of Origin:
China
Model Number:
BD-AI
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai
Delivery Detail:
Delivery time depends on order quantity.
Brand Name Acrel
Place of Origin China
Model Number BD-AI
Usage Other, current transducer
Theory Current Sensor
Output Analog Sensor
General
BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current,voltage
frequency, power, power factor or temperature, resistance and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A / D converter, and the computer system.
Parameters


Technical parameters
Value
Accuracy class
0.5、0.2





Input
Nominal value
CurrentAC、DC 1A、5A;
VoltageAC、DC 100V、300V、500V 
Overload
Continual 1.2 times, Instantaneous current 10 times/5s; Instantaneous voltage 2 times/30s;
Consumption
≤0.3VA Current input; Voltage input,
≤0.3VA100V ,≤0.6VA300V ,≤1VA500V 
Frequency
50±5Hz,60±5Hz



Output
Normal value
DC:4-20mA、0-20mA, 0-5V, 0-10V And so on
Load resistance
Current output≤600Ω
Voltage output≥1000Ω
Ripple content
<0.5%peak value
Response time
≤400ms

Power supply
Voltage
AC85-265V、DC100-350V
Consumption
AC current, voltage≤3VA,
Power≤4VA
Insulation resistance
≥100MΩ
Isolation voltage
Among input//output//power supply
2.0kV/1min, 50Hz
Temperature modulus
≤200ppm/℃



Environment

Temperature
work-10℃~+55℃ Storage: -25℃~+70℃
Humanity
≤90%RH(In the place without dew and corrosive gas)
Altitude
≤2000m
Fix mode
(Rail, or fix to cubicle with bolt)


Contact us

Overseas sales engineer: Dante Bao

Mob:+86 18706163573(whatsapp/skype/wechat)

Product Tags: single phase ac current transducer , 4-20mA output current sensor , PLC current transducer

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2006
Annual Export Value
US$1.5 Million - US$2.5 Million
Product Certifications
ISO9001

Recommended Categories

Explore top categories and find suppliers for your specific needs