1、 Overview
A. The pneumatic on-off valve is mainly used as the switch in the powder material flow control system. It is usually used in series with flow control valve. Pneumatic on-off valve is driven by cylinder to realize the switch function.
B. In structure, there is no difference between the pneumatic on-off valve and the electric on-off valve. The main difference is that the driving force of the sliding block in the valve body to change the valve position is different. The pneumatic on-off valve is sent by the control air in the air circuit (pipe) to the operating cylinder in the valve to push the piston to move and drive the slider to change the valve position of the valve body; the electric on-off valve uses the electromagnetic suction force generated by the spiral coil to drive the slider to change the valve position of the valve body. Because the pneumatic on-off valve changes the valve position by controlling the air in the cylinder to form a certain pressure, the piston and slider can be pushed to change the valve position of the valve body. In actual control, the switching speed is relatively slow, while the speed of electric on-off valve current producing suction force is relatively fast, so from the perspective of working speed, the electric on-off valve acts faster.
C. In addition, the control signal of the pneumatic on-off valve is the air pressure signal, which must be connected with the pipe, so the volume of the electric on-off valve is smaller than that of the pneumatic switch valve, because the control signal of the electric on-off valve is generally the current signal, which can be connected by wire, and there is no operating plunger.
2、 Technical parameter table
name | Company | B250 | B300 | B400 | |
valve body | Flow* | m3/h | 120 | 160 | 220 |
Velocity of flow* | m/s | 3 | 3 | 3 | |
Angle θ | degree | 71 | 71 | 71 | |
external diameter | mm | 260 | 280 | 320 | |
length | mm | 330 | 405 | 410 | |
Circulation area | m2 | 0.0148 | 0.025 | 0.0425 | |
gas Cylinder | model | QGBⅡ100x200-MP2 | QGBⅡ100x200-MP2 | QGBⅡ100x200-MP2 | |
internal diameter | mm | 100 | 100 | 100 | |
trip | mm | 200 | 200 | 200 | |
working pressure | MPa | 0.15-1 | 0.15-1 | 0.15-1 | |
Installation type | Double lifting lug | Double lifting lug | Double lifting lug | ||
Thorough gas layer | Material Science | Nylon | Nylon | Nylon | |
Air permeability area | m2 | 0.05 | 0.07 | 0.09 | |
Power consumption | m3/min | 0.5 | 0.5 | 0.5 | |
3、 Actual product drawing
Send Inquiry to This Supplier
You May Also Like
-
Cement Motorized Flow Control GateNegotiableMOQ: 1 Set
-
Pneumatic Flow Control Gate\\motorized Flow Control GateNegotiableMOQ: 1 Set
-
Pneumatic Gate Valve Pneumatic Shut-off Valve Chute Stop Valve National Standard Channel Steel Manufacturer OrderNegotiableMOQ: 1 Set
-
Sealing and Wear Resistance of Discharge Valve at Bottom of Cement SiloNegotiableMOQ: 1 Set
-
Factory Direct Selling of Pneumatic Shut-off Valve for Chute Gate ValveNegotiableMOQ: 1 Set
-
Bottom Electric Flow Valve Pneumatic Flow Valve Bottom Unloading DeviceNegotiableMOQ: 1 Set
-
Pneumatic Chute Gate Valve Gas Delivery Gate Valve Chute Retaining Gate Valve Support CustomizationNegotiableMOQ: 1 Set
-
The Discharging Device at the Bottom of Cement Silo is Suitable for Discharging Powdery MaterialsNegotiableMOQ: 1 Set
-
The Discharging Device at the Bottom of Cement Silo is Suitable for Discharging Powdery MaterialsNegotiableMOQ: 1 Set
-
The Discharging Device at the Bottom of Cement Silo is Suitable for Discharging Powdery MaterialsNegotiableMOQ: 1 Set