SNV308.1Short circuit fault indicator
Description
Overhead power line fault indicator with Three color light display suitable for overhead lines with a 50KV below four remotes short circuit &Earth fault indicator, through measuring the current of a cable, to judge the fault on the power lines according to the change of current, grounding fault, and the fault state, real time current, battery voltage and other information is uploaded to the remote server, which provides reliable data for the various types of fault diagnosis and location of overhead lines
Function display
Flag state
1) Normally, Flag is on blanket position. Every 3hour, Flag will reset one times for avoiding un fault turn to red flag.
2) When short circuit fault happen, it will turn to red flag state; After reach reset time or when the line current restore, Fault indicator will turn back to blanket state;
3) when the earth fault happen, it will turn to red flag state. It will be automatically turn back blanket state when line power off and current restore, or wait until reach reset time.
Fault indicating Led light:
1) short circuit permanent fault indicating: Six 3-color led will shine red color, and four times, every 2 second,And turn to red flag at same time。
2) short circuit temporary fault indicating: Six 3-color led will shine green color, and four times, every 2 second,And turn to red flag at same time。
3) Earth Fault indicating:Six 3-color led will shine Blue color, and four times, every 2 second. And turn to red flag at same time.
yellow state Led light:
Battery voltage too low:Shine 1 time, every2second
Battery voltage low: shine 2 time, evey2second
Wireless setting state: shine 4 times, every 2 second
Send Inquiry to This Supplier
You May Also Like
-
Overhead Type Short Circuit & Earth Fault Indicator ManufacturerUS$ 1 - 2MOQ: 1 Set
-
Medium Voltage Overhead Line Fault Current Sensor and IndicatorUS$ 1 - 2MOQ: 1 Set
-
Remote Wireless Communication Terminal for Overhead Grounding and Short Circuit FaultUS$ 1 - 2MOQ: 1 Set
-
Overhead Line Fault SensorUS$ 1 - 2MOQ: 1 Set
-
High Voltage Cable Fault AlarmUS$ 1 - 2MOQ: 1 Set
-
Overhead Type Short Circuit &Ground Fault IndicatorUS$ 40 - 60MOQ: 1 Set
-
Electric Power Overhead Line Current Fault Indicator for Smart-gridsUS$ 1 - 2MOQ: 1 Set
-
Overhead Type Fault Indicator and Wireless Communication ModuleUS$ 1 - 2MOQ: 1 Set
-
Flag Type Overhead Type Short Circuit &Ground Fault IndicatorUS$ 1 - 2MOQ: 1 Set
-
Chinese Factory Overhead Line Cable Fault LocatorUS$ 1 - 2MOQ: 1 Set