- Zhuhai City Snova Technology Co., LTD
- China Manufacturer with main products:Earth Fault Indicator ,Cable Fault Indicator ,Overhead Line Ground Fault Indicator ,Short Circuit and Earth Fault Indicator ,Cable Temperature and Faults Sensor ,Industrial Dehumidifier ,Temperature and Humidity Controller ,Fault Passage Indicator ,Remote communication terminal ,Smart grid system
Home > Products > Short Circuit and Earth Fault Indicator > SNV-EFI Earth Fault Indicator
SNV-EFI Earth Fault Indicator
- 1 Piece / Pieces per Month
- Control PDA for Fault Locator In Transmission Lines
- Grounding Faul Indicator earth fault indicator
- Electric Handcart and Ground Knife Integrated Protector
- fault locator of Power distribution equipment
- SNV-EKL4 V2.1 Earth Fault Indicator cable sensor
- Grounding Fault Sensor and Current Short Circuit Indicator
Product Description
SNV-EFI Earth fault indicator
Type: surface mounted
Description
SNV-EFI earth fault indicator, it Widely used in various ring cabinets, high/ Medium or low -voltage switch
gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type of
power grid in the Low/medium voltage network. The use of cable type grounding fault indicator is an efficient
way to check cable fault, and is an effective way to improve the operation level of distribution network and the
efficiency of fault handling. The design uses electromagnetic induction, and single chip microcomputer control
technology to make fault alarm with high accuracy and strong anti-interference ability.
Equipped with fault remote transmission port, suitable for distribution network automation; Battery low
power alarm indication; Low-power design, high-capacity lithium battery power supply, long battery life (more
than 10 years); external structure using card or lock design, the whole machine is easy to load and unload.
Function character :
1) Intelligent detection of ground fault and through the corresponding LED on the display unit to indicate
fault.
2)Display unit designed with button, it is convenient for reset or test.
3)The pulse width time of fault current can be set to prevent incorrect fault indication caused by surge
current.
4)It can reset and detect the remote fault indication device remotely by Scada or press key.
5)It can provide switch volume for external devices through remote contact.
6)It can choose the reset time after fault happen (when purchase, it need to tell factory to set,default
8hours).
7)Remote fault indicating can be made by external lamp.
8)Earth fault alarm current,Multi-level can be settable through a DIP inside of the display nit(optional)
9)Low battery display and alarm test through press the “Test/reset” key by 3seconds.
10) Battery can be changeable conveniently.
Function description
1) Earth fault alarm indicating: when the earth fault sensor detected an earth fault current, and the current
is bigger than equal to or equal to the setting value, then the earth fault sensor send a signal to display unit
through electric cable. And the display unit will display the alarm signal, at same time, the earth fault LED will be
blinking.
2) Battery low voltage alarm indicating: the display unit use the battery to supply power. When we press the
“Test” button,3seconds time: If the battery voltage is lower than the Min. working voltage 2.5V, then the Battery
Level Led will be blinking 5 times; If battery voltage is normal, then only blink 1 times.
4)Automatic time reset: After the indicator alarm the fault, if there are without manual reset it, when the
time reach our reset time setting, indicator will automatically reset.
5) Manual reset: After the indicator alarm the fault, user can press the button “ reset/test” in a short time
to reset it.
6)Automatic Low voltage reset: Through inputting AC110-240V power to the pin 10,11 on the PCB in the
display unit, when fault indicating, at same the voltage powered off. when the voltage recover and power on
again, then indicator will be reset immediately via low voltage.
7) Out side AC110-240V power supply energy for display unit. It use the same as voltage of the “voltage
reset” via pin 10,11.
8) Remote(Scada) reset/test: through short connect the pin 3,4, then indicator will be run the reset/test
process, and Led will be blinking. *Connect the pin 3,4 by short time(1second), then it will be reset indicator. *
connect the pin3,4 by a long time(3seconds), then it will be test indicator.
9)Remote indicating: Through connect the pin 5,6 to the external lamp , then it will be indicate fault when
any phase alarm fault
Contact Us
- Zhuhai City Snova Technology Co., LTD
- Contact nameAndrewmao
- Phone86-13570657698-8621065
- AddressXiangzhou district Zhuhai,Guangdong
- 12 Meters Hotstick Installation adapter of Overhead Line Fault Indicator
- 12 Meters Hotstick Installation adapter of Overhead Line Fault Indicator
- SNV-EKL4 V2.1 short circuit fault sensor for distribution network
- Industrial intelligent dehumidifier for distribution cabinet
- Simulated Failure Remote Controller for Overhead Line Fault Indicator
- Medium-voltage Distribution System Short-circuit and Ground Fault Device
- How to install Cable type earth fault and short circuit indicator EKL4
- How to install Cable type earth fault and short circuit indicator EKL4
- Cable short circuit and grounding fault indicator SNV-EKL3.2
- what is Overhead line short circuit and grounding fault sensor ?SNV308 FPI
- Vertical Break Isolating Switch Comprehensive Protection Device
- Medium-voltage Distribution System Short-circuit and Ground Fault Device
- Medium-voltage Distribution System Short-circuit and Ground Fault Device
- New type digital Intelligent overhead line type cable short circuit and ground fault indicator for power distribution line SFI
- New type digital Intelligent overhead line type cable short circuit and ground fault indicator for power distribution line SFI
- Fault Indicator Remote Wireless Communication Terminal
- Fault Indicator Remote Wireless Communication Terminal
- China factory supplier Power Accessories
- current and temperature online inspection fault sensor
- On-line current temperature short circuit fault detector
- SNV-EKL3.2 Short circuit and earth fault indicator with multigear
- Fault Indicator Remote Wireless Communication Terminal
- SNV309 wireless comunication terminal with SCADA system
- Earth fault locator
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Accessories
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andrewmao
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-