- Acrel Electric Co., Ltd
- China Manufacturer with main products:Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement
Home > Products > NEW Energy > one phase three wire AGF pv solar energy meter rs485 modbus din rail installed with UL used in Australia Europe North America
one phase three wire AGF pv solar energy meter rs485 modbus din rail installed with UL used in Australia Europe North America
Negotiable
1 (Min.Order)
- 1000 per Month
- T/T Credit Card
You May Like
- ACR10R-D10TE4 china energy meters din rail energy meter for solar inverter prices
- 16 channel multi channel din rail smart solar string monitor device for pv combiner box AGF-M16T-P2 DC1000V or DC1500V
- Acrel AGF-M12T-P2 12 channel DC0-20A solar power meter combiner box for solar panel PV DC1000V power supply
- ARTU100-KJ8/CE 8DI/8DO Remote Terminal Units ethernet communication 8 channels data collection
- 32 channel data exchange device collect switch signals convert to digital signals ARTU100-K32 Remote Terminal Units
- Remote Terminal Units ARTU100-KJ8MA84 analog collection 8AI+4AO DC4-20mA 0-5V
Product Description
AGF-AE-D Bidirectional Reflux Monitoring Meter (1-phase,3-wire with UL certificate)
Products Description
● Measurement: Active Powr, Reactive Power, Current, Voltage and etc
● Wiring: 1-phase 3-wire Connection
● Current Rating: 100A or 200A AC (paired with external CTs)
● Communication: RS485 (MODBUS-RTU)
● Application: Using in distributed Solar PV and Anti-reflux Inverters
● Dimension: 54.1*87.8*52mm (H*W*D)
● Installation: 35mm DIN Rail
● Standard&Certificate: UL1741;TUV
PV Dedicated Two Channels AC Power Meter
In a single inverter system, the meter is connected directly to the inverter. If your inverter has a built-in revenue grade
meter(RGM; the inverter is referred to a revenue grade inverter), you can connect an external meter on the same bus as the RGM.
In a single inverter system, the meter is connected directly to the inverter. If your inverter has a built-in revenue grade
meter(RGM; the inverter is referred to a revenue grade inverter), you can connect an external meter on the same bus as the RGM.
Used for distributed Solar PV
● Reflux Monitoring
● Connected with Load Line through CTs
● Directly connect with inverters
Single-phase Three-wire Connection
● Rated Voltage of Line to N: 120V
● Rated Voltage of Line to Line: 208/240V
● Grids Supported: L1/L2/N/PE
● Rated Voltage of Line to N: 120V
● Rated Voltage of Line to Line: 208/240V
● Grids Supported: L1/L2/N/PE
RS485 Communication
● MODBUS-RTU Protocol
● Communicate with Inverter to realize anti-reflux Function
● Response Time: ≤1s
● MODBUS-RTU Protocol
● Communicate with Inverter to realize anti-reflux Function
● Response Time: ≤1s
Bidirectional Metering
● Active&Reactive Energy Metering
● Rated RMS Current: 100/200A
● Accuracy: ±0.5%/±1%
● Active&Reactive Energy Metering
● Rated RMS Current: 100/200A
● Accuracy: ±0.5%/±1%
Technical Parameter
Meter Electrical Service | Units | |||||
AGF-AE-D/100 | AGF-AE-D/200 | |||||
Rated Voltage-Line to N | 120 | V | ||||
Rated Voltage-Line to Line | 208/240 | V | ||||
Extended Voltage Range | 88%~110% | |||||
AC Frequency | 60 | Hz | ||||
Grids Supported | L1/L2/N/PE | |||||
Power Consumption | 1.2 | W | ||||
Communication | ||||||
Meter Communication Interfaces | RS 485 | |||||
Response Time | ≤1 | S | ||||
Meter Accuracy | ||||||
Rated RMS current | 100 | 200 | A | |||
1%-100% of CT Current | ±0.5 | ±1 | % | |||
Current Transformers | ||||||
Number of Supplied Current Transformers | 2 | |||||
Dimensions | I.D:15 O.D:35 | 70.5×54.5×39 (H×W×D) | mm | |||
Standard Compliance | ||||||
Safety | UL1741 | |||||
Installation Specifications | ||||||
Dimensions(H×W×D) | 54.1×87.8×52 | mm | ||||
Weight | 0.2 | kg | ||||
Operating Temperature Range | -30~55 | ℃ | ||||
Relative Humidity (noncondensing) | 5 - 90 | % | ||||
Mounting Type | DIN-Rail,35mm |
The meter is intended to be installed in a power distribution box in the end use. The acceptance of the application is to be evaluated in the end product.
Wiring Illustration
Connected with Load Line through CTs
Directly connect with inverter
Dimension & Installation
Solution Structure
Certification
Company Profile
FAQ
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang
- Phone86-21-18702111813
Product Categories
New Products
- 16DI multi-channel monitor ARTU100-K16 Series Remote Terminal Units Switch value collection
- ARTU100-KJ8 Series Remote Terminal Units
- AWT100-POW power module for AC/DC220V power supply 24 convert to 220v
- AWT100-wifiHW indoor high precision wireless gateway communication terminal 485communication interface
- indoor high precision wireless device smart gateway wireless communication terminal AWT100-loraHW 485communication interface
- AWT100-4GHW lora communication lot wireless device smart gateway wireless communication terminal 485 communication interface
- MQTT lot wireless device smart gateway wireless communication terminal AWT100-4GHW 4G 485 communication interface
- smart gateway wireless communication terminal AWT100-4GHW 4G 485 communication interface
- Acrel remote terminal unit RTU rs485 Modbus-rtu ARTU-K16 collect 16 switch signals for smart power distribution
- Acrel Din Rail ARTU -K32 Multi-Circuit Remote Terminal Unit collect 32 switch signals with RS485 Modbus
- smart gateway wireless communication terminal AWT100-CEHW data logger
- GPS location AWT100-GPS smart gateway wireless communication terminal RS485 communication interface
- wireless data logger smart gateway wireless communication terminal AWT100-loraHW
- motor overload protection devices ALP300 low voltage Motor Protection Controller
- ALP300 low voltage Motor Protection Controller
- Residual current circuit breakers Type A leakage current operated relay for street light system
- TT and TN system distribution lines type A leakage current operated protective residual relay monitors
- Low voltage electrical system protection din rail mounted digital earth leakage earth fault protective relay
- Type A two-pair rely output earth fault protective device rail mounted residusl current operated relay
- Acrel Din rail 35mm leakage fault current operated relay protective device for sale
- High quality multistage adjustable residual current protective device for electrical fire and hirearchical protection
- China manufacturer one channel multistage adjustable leakage residual current protective repay
- ASJ10-LD1A type A earth fault leakage current protective device relay for leakage protection
- CE certificated din rail 35mm two pair relay output type A leakage fault monitor residual current operated reply
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Contact supplier for lowest price
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-