Home > Products > surface area and porosimetry analyzers > V-Sorb 2800TP surface area and pore size distribution analyser
V-Sorb 2800TP surface area and pore size distribution analyser
- 30 Set / Sets per Month
- Shanghai
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
- V-Sorb 4800 BET surface area and pore volume analyzer
- V-Sorb 4800P surface area and pore size analyzer
- V-Sorb 4800S specific surface area analyzer
- V-Sorb 4800TP surface area and porosimetry analyzer
- H-Sorb 2600PCT hydrogen adsorption isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption PCT isotherms determination analyzer
Product Details
Brand Name: | Gold APP Instruments | Place of Origin: | China | Model Number: | V-Sorb 2800TP |
Product Description
V-Sorb 2800TP surface area and pore size distribution analyser introduction
V-Sorb 2800TP surface area and pore size distribution analyser is manufactured by Gold APP Instruments engineers for specific surface area, pore volume and pore size related data testing, especially for super micropore testing. It has a turbo molecular vacuum pump and 0.1 torr pressure sensor, also equips 316L stainless steel manifold pipelines, can make to reach a very low pressure with high accuracy.
V-Sorb 2800TP surface area and pore size distribution analyser applications
1. Super micro powder, nanomaterials, particle and fiber etc. samples specific surface area, pore size distribution, pore volume etc. analysis.
2. Government institutes and universities for researching work
V-Sorb 2800TP surface area and pore size distribution analyser parameters
1. Test Principle: static volumetric adsorption
2. Test Data: adsorption and desorption isotherms, single and multipoint BET (Brunauer-Emmett-Teller) surface area, Langmuir surface area, external surface area, BJH (Barrett-Joyner-Halenda) total pore volume and pore size distribution, T-plot micropore, MP micropore, Horvath-Kawazoe (HK) micropore, Saito-Foley (SF) micropore, Dubinin-Radushkevich (DR) micropore, Dubinin-Astakhov (DA) micropore, carbon black (STSA) etc.
3. Vacuum System: V-Sorb unique stainless steel micro welding vacuum manifolds system, metal-to-metal (VCR) fittings, reduce dead space in maximum degree and also keep long duration high vacuum; the VCR metal fittings’ vacuum leak rate can reach 1x10-10 (Pa m3/s), absolutely without usage of any O-ring sealing which will release gas to affect vacuum purity when under high vacuum condition
4. Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit (specific surface area); 0.35 to 500nm (pore size)
5. Accuracy: repeatability errors within 1%
6. Data Acquisition: high-precision and high integration data acquisition and archiving system, minimal error, strong anti-interference ability
7. Sample Ports: 2 analyzing and 2 degassing work simultaneously and independently
8. Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument’s stability and life
9. Pressure Measurement: branded pressure transducer greatly improve the measuring accuracy at low P/Po point, 1000Torr, 1Torr and 0.1Torr three pressure transducers are equipped
10. Transducer Accuracy: pressure transducer accuracy can reach 0.1% of real reading
11. Vacuum Pump: built-in mechanical vacuum pump and turbo pump be controlled by software
12. Dewar: branded 4 liter stainless steel Dewar can provide at least 72 hours of unattended measurement without refilling the LN2
13. Partial Pressure: P/Po controllable accuracy range is 5x10-8-0.998
14. Ultimate Vacuum: bipolar pump: 4x10-2Pa (3x10-4Torr), molecular pump: 5x10-8 mbar
V-Sorb 2800TP surface area and pore size distribution analyser features
1. Stainless steel micro welding vacuum manifolds system can reduce the leak rate apparently and improve ultimate vacuum.
2. Micro welding vacuum system can decrease manifolds dead volume, increases measuring sensitivity and improve accuracy.
3. Equip turbo vacuum pump, ultimate vacuum value can reach 5x10-8-0.998 mbar, maintenance free, convenient to use.
4. Branded high vacuum pneumatic valve sealing performance is up to 5x10-12 (Pa m3/s).
5. Fully metal-to-metal VCR connecting eliminate O-ring gas release problem when under high vacuum circumstance, efficiently improve ultimate vacuum and analysis reliability.
6. Modularity design can configure as customer requests, easy for future upgrading and maintenance.
7. Programmable pneumatic valve system with high integration and strong anti-interference ability.
8. Multi calculating formulas for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation Limited
- Contact nameAndy
BET surface area analyzers | surface area and porosimetry analyzers | helium true density analyzer | high pressure volumetric adsorption analyzer |
hydrogen adsorption analyzer |
- H-Sorb 2600PCT H2 adsorption PCI isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption TPD isotherms determination analyzer
- G-DenPyc 2900 True Density & Helium Pycnometry Analyzer
- G-DenPyc 2900 Gas (Helium) Pycnometer Theory and Practice
- G-DenPyc 2900 density measurement with a helium pycnometer
- G-DenPyc 2900 porosity determination with helium pycnometry
- G-DenPyc 2900 Gas Pycnometer and Helium Pycnometers
- G-DenPyc 2900 Gas Pycnometer for Semi-Solid and Solid Density
- G-DenPyc 2900 Professional Gas Pycnometer
- G-DenPyc 2900 Air and Helium Pycnometer
- G-DenPyc 2900 Fully Automated Gas Pycnometer
- G-DenPyc 2900 Analytical Grade Pycnometer
- H-Sorb 2600 Hydrogen Storage Analyzer
- H-Sorb 2600 High Temperature Hydrogen Storage Gas Adsorption Analyzer
- H-Sorb 2600PCT High Pressure Gas Adsorption Analyzers
- H-Sorb 2600PCT Hydrogen Storage Materials and Sorption Analysis Equipment
- H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption
- H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption Analyzer
- H-Sorb 2602PCT Automatic High-pressure Gas Adsorption Analyzer
- F-Sorb 2400CE Single-Point and Multi-Point Surface Area Measurements
- F-Sorb 2400CE the single point BET method
- F-Sorb 2400CE Brunauer-Emmett-Teller (BET) surface area analysis
- F-Sorb 2400CE BET Surface Area Analysis of Nanoparticles
- F-Sorb 2400CE BET Specific Surface Area Testing
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-