Home > Products > BET surface area analyzers > V-Sorb 2800S surface area analyzer
V-Sorb 2800S surface area analyzer
- 30 Set / Sets per Month
- Shanghai
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
- V-Sorb 2800TP surface area and pore size distribution analyser
- V-Sorb 4800 BET surface area and pore volume analyzer
- V-Sorb 4800P surface area and pore size analyzer
- V-Sorb 4800S specific surface area analyzer
- V-Sorb 4800TP surface area and porosimetry analyzer
- H-Sorb 2600PCT hydrogen adsorption isotherms determination analyzer
Product Details
Brand Name: | Gold APP Instruments | Place of Origin: | China | Model Number: | V-Sorb 2800S |
Product Description
V-Sorb 2800S surface area analyzer introduction
V-Sorb 2800S surface area analyzer is researched and developed by Gold APP Instruments for single and multi-point BET (Brunauer-Emmett-Teller) specific surface area, also with Langmuir surface area and others related with SSA (specific surface area) by using static volumetric principle. Compared with other analyzers, multi pioneered techs make its performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in international competitors.
Analyzers designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customer real demands. High cost performance of V-Sorb 2800S BET surface area analyzer easily ensure your investment profits and flexible equipped peripheral can satisfy different users requests.
V-Sorb 2800S surface area analyzer application fields
1. Super micro powder, nano materials, nano-particles and fiber shaped specific surface area analysis.
2. Product quality control for powder, particles etc. materials related companies.
3. Researching institutes, universities for BET (Brunauer-Emmett-Teller) theory teaching.
4. Fuel cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc. surface area data determination.
5. Other researches concern specific surface area performance.
V-Sorb 2800S surface area analyzer specifications
1. Analysis Principle: static volumetric nitrogen adsorption
2. Testing Methods: adsorption and desorption isotherms, single and multi-point BET (Brunauer-Emmett-Teller) surface area, Average particle diameter estimation, t-plot external surface area, true density analysis, Langmuir surface area, carbon black (STSA-Statistical thickness surface area), adsorption constant C.
3. Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit
4. Accuracy: repeatability errors within 1%
5. Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; decrease connecting points; strengthen sealing performance and prolonged instrument working life
6. Coolant Level Prober: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change
7. Sample Pretreatment: the whole pretreatment procedures are controlled by dedicated software, as well with a start time preset function which can realize unattended operation at night
8. Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument stability and life
9. Sample Ports: two samples analyzing and two samples degassing concurrently
10. Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, standard equips 1000Torr (0-133Kpa) transducer, 10 Torr is option
11. Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge (general error is 10%-15%)
12. Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998
13. Ultimate Vacuum: 4x10-2Pa (3x10-4 Torr)
14. Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pumps start/stop
15. Sample Types: powders, nanoparticle, fiber, flakes and other materials
16. Adsorbate Gas: high purity nitrogen (99.999%), Ar, Kr, CO, CO2, C4H10 etc. non-corrosive gases are optional
17. Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability
18. Data Reduction: Windows-based independent developed Gold APP Instruments software, perfect versatility, produced full featured and multi-model reports
V-Sorb 2800S surface area analyzer technical features
A: Vacuum System
1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.
2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.
3. Imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).
B: Control System
1. Industry type programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.
2. Separated analysis and pretreatment manifolds can prevent foreign matter to contaminate manifolds during sample pretreatment.
C. Measures for Improving Accuracy
1. Imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).
2. 10Torr (optional) and 1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum.
3. Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.
4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change.
5. Pioneered gas outlet and inlet control system can efficiently prevent samples splash in vacuuming and gas inlet procedures, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducers macro-change.
D. Data Acquisition and Reduction
1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzers applications extension and interconnection, can also conveniently switched to RS232 and USB modes.
2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation Limited
- Contact nameAndy
BET surface area analyzers | surface area and porosimetry analyzers | helium true density analyzer | high pressure volumetric adsorption analyzer |
hydrogen adsorption analyzer |
- H-Sorb 2600PCT H2 adsorption PCT isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption PCI isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption TPD isotherms determination analyzer
- G-DenPyc 2900 True Density & Helium Pycnometry Analyzer
- G-DenPyc 2900 Gas (Helium) Pycnometer Theory and Practice
- G-DenPyc 2900 density measurement with a helium pycnometer
- G-DenPyc 2900 porosity determination with helium pycnometry
- G-DenPyc 2900 Gas Pycnometer and Helium Pycnometers
- G-DenPyc 2900 Gas Pycnometer for Semi-Solid and Solid Density
- G-DenPyc 2900 Professional Gas Pycnometer
- G-DenPyc 2900 Air and Helium Pycnometer
- G-DenPyc 2900 Fully Automated Gas Pycnometer
- G-DenPyc 2900 Analytical Grade Pycnometer
- H-Sorb 2600 Hydrogen Storage Analyzer
- H-Sorb 2600 High Temperature Hydrogen Storage Gas Adsorption Analyzer
- H-Sorb 2600PCT High Pressure Gas Adsorption Analyzers
- H-Sorb 2600PCT Hydrogen Storage Materials and Sorption Analysis Equipment
- H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption
- H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption Analyzer
- H-Sorb 2602PCT Automatic High-pressure Gas Adsorption Analyzer
- F-Sorb 2400CE Single-Point and Multi-Point Surface Area Measurements
- F-Sorb 2400CE the single point BET method
- F-Sorb 2400CE Brunauer-Emmett-Teller (BET) surface area analysis
- F-Sorb 2400CE BET Surface Area Analysis of Nanoparticles
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-