Module Spare Parts 6637517A1 660-MISC-3311
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 6637517A1 660-MISC-3311 |
codes Explanation Description Remarks for ordering A- A0 none rated current for protection transformers A1 1 A A5 5 A B- B0 none rated current for measurement transfomers B1 1 A B5 5 A U- U0 none rated voltage U1 100 V AC U2 200 V AC K-/L- K01 6 CTs (3ph Code A-) VT, CT and MT arrangements of N-/O- L01 1 MT (1ph Code B-) analog input transformer unit P-/Q- N01 2 VTs (1ph Code U-) O01 3 VTs (3ph delta Code U-) P01 Q01 K-/L- K02 6 CTs (3ph Code A-) Typ 216GW62 N-/O- L02 3 MTs (3ph Code B-) Explanation: P-/Q- N02 3 VTs (3ph delta Code U-) CT = current transformer protection core O02 MT = current transformer measurement core P02 VT = voltage transformer Q02 K-/L- K03 6 CTs (3ph Code A-) N-/O- L03 3 VTs (3ph delta Code U-) P-/Q- N03 3 VTs (3ph delta Code U-) O03 P03 Q03 K-/L- K04 6 CTs (3ph Code A-) N-/O- L04 1 CT (1ph Code A-) P-/Q- N04 1 MT (1ph Code B-) O04 1 VTs (1ph Code U-) P04 3 VTs (3ph delta Code U-) Q04 K-/L- K05 9 CTs (3ph Code A-) N-/O- L05 1 MT (1ph Code B-) P-/Q- N05 2 VTs (1ph Code U-) O05 P05 Q05 K-/L- K06 9 CTs (3ph Code A-) N-/O- L06 3 VTs (3ph delta Code U-) P-/Q- N06 O06 P06 Q06 K-/L- K07 12 CTs (3ph Code A-) N-/O- L07 P-/Q- N07 O07 P07 Q07 Numerical Generator Protection REG216 / REG216 Classic 1MRB520004-Ben Page 31 ABB Switzerland Ltd Power Technology Systems Subcodes Explanation Description Remarks for ordering K-/L- K08 9 CTs (3ph Code A-) N-/O- L08 3 MTs (3ph Code B-) P-/Q- N08 O08 P08 Q08 K-/L- K09 3 CTs (3ph Code A-) N-/O- L09 3 MTs (3ph Code B-) P-/Q- N09 3 VTs (3ph delta Code U-) O09 2 VTs (1ph Code U-) P09 1 MT (1ph Code B-) Q09 K-/L- K10 6 CTs (3ph Code A-) N-/O- L10 3 VTs (3ph delta Code U-) P-/Q- N10 3 VTs (1ph Code U-) O10 P10 Q10 K-/L- K11 9 CTs (3ph Code A-) N-/O- L11 3 VTs (3ph star Code U-) P-/Q- N11 O11 P11 Q11 K-/L- K12 3 CTs (3ph Code A-) N-/O- L12 3 VTs (3ph delta Code U-) P-/Q- N12 1 VT (1ph Code U-) O12 1 MT (1ph Code B-) P12 1 VT (1ph 95% Stator earth fault protection Q12 3 VTs (special) 100% Stator + Rotor earth fault protection K-/L- K13 6 CTs (3ph Code A-) N-/O- L13 3 VTs (3ph delta Code U-) P-/Q- N13 1 VT (1ph 95% Stator earth fault protection O13 2 VTs (special) 100% Stator earth fault protection P13 Q13 K-/L- K14 3 CTs (3ph Code A-) N-/O- L14 3 VTs (3ph delta Code U-) P-/Q- N14 1 MT (1ph Code B-) O14 1 CT (1ph Code A-) P14 1 MT (1ph Code B-) Q14 3 VTs (3ph delta Code U-) K-/L- K15 2 VTs (1ph Code U-) N-/O- L15 1 CT (1ph Code A-) P-/Q- N15 9 CT (3ph Code A-) O15 P15 Q15 Numerical Generator Protection REG216 / REG216 Classic 1MRB520004-Ben Page 32 Ordering (cont´d) ABB Switzerland Ltd Power Technology Systems Subcodes Explanation Description Remarks for ordering K-/L- K16 2 VTs (special) 100% Stator earth fault protection N-/O- L16 1 CT (1ph Code A-) P-/Q- N16 9 CT (3ph Code A-) O16 P16 Q16 K-/L- K18 6 CTs (3ph Code A-) N-/O- L18 1 CT (1ph Code A-) P-/Q- N18 1 MT (1ph Code B-) O18 1 CT (1ph Code A-) P18 3 VTs (3ph delta Code U-) Q18 K-/L- K19 3 VTs (3pn delta Code U-) N-/O- L19 3 VTs (3ph delta Code U-) P-/Q- N19 1 CT (1ph Code A-) O19 1 MT (1ph Code B-) P19 1 CT (1ph Code A-) Q19 1 VT (1ph 95% Stator earth fault protection 2 VTs (special) 100% Stator earth fault protection The above mentioned devices are included in the code Mx. The number and types of CPUs, power supply, system cable length and protocol must be specified by the code G- G1 165..312 V DC 1. DC/DC converter System A G2 82....156 V DC supply voltage G4 36.....75 V DC H- H0 none 2. DC/DC converter System A H1 165..312 V DC supply voltage for variants M1-M6 and M21-M25 optional H2 82....156 V DC redundant DC/DC converter can be used H4 36.....75 V DC E- E0 none 1.
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts 81EU01E-E GJR2391500R1210 GJR2391511R42US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 8200-1302US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 83SR04C-E GJR2390200R1411US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 83SR06B-E GJR2395400R1210US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 8440-1713 DUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts ASE2UDC920AE01 3BHB022793R0001US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts BCU-02 3AUA0000110429US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts BCU-12 3AUA0000110430US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts CI546 3BSE012545R1US$ 1 - 100000MOQ: 1 Piece
-
Module Spare PartsCI687K01 3BSE043660R1US$ 1 - 100000MOQ: 1 Piece