Module spare parts 5X00063G01
- 1 Piece / Pieces per Month
- xiamen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
Product Details
Brand Name: | ABB | Model Number: | 5X00063G01 |
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
5X00063G01 |
Table 24: Overexcitation function with inverse time delay (24) Features: • Single-phase measurement • inverse time delay • According to IEEE Guide C37.91-1985, setting made by help of table settings Settings: Table settings U/f values: (1.05; 1.10 to 1.50) UN/fN Start value U/f 1.05 to 1.20 UN/fN in steps of 0.01 UN/fN tmin 0.01 to 2 min in steps of 0.01 min tmax 5 to 100 min in steps of 0.1 min Reset time 0.2 to 100 min in steps of 0.1 min Reference voltage 0.8 to 1.2 UN in steps of 0.01 UN Accuracy of pick-up value ±3% UN/fN (at fN) Frequency range 0.5 to 1.2 fN Reset ratio 100% Starting time <120 ms ABB Switzerland Ltd Numerical Generator Protection Power Technology Systems REG216 / REG216 Classic 1MRB520004-Ben Page 19 Table 25: Voltage balance function (60) Features: • Comparing of the voltage amplitudes of two groups of voltage inputs (line 1, line 2) • Single- or three-phase voltage measurement • Signalling of the group having the lower voltage • Evaluation of the voltage differences per phase for the 3-phase function and logic OR connection for the tripping decision • Variable tripping and reset delay • Suppression of DC components • Suppression of harmonics Fig. 7 Tripping characteristic Voltage comparison (shown for the phases R and the setting value volt. diff. = 0.2 • UN) Settings: Voltage difference 0.1 to 0.5 UN in steps of 0.05 UN Trip delay 0.00 to 1.0 s in steps of 0.01 s Reset delay 0.1 to 2.0 s in steps of 0.01 s Numbers of phases 1 or 3 Maximum tripping time without delay ≤50 ms U1R: U2R: phase R voltage amplitude voltage channel 1 (line 1) phase R voltage amplitude voltage channel 2 (line 2) For 3-phase function: the characteristic is valid accordingly for the phases S and T Numerical Generator Protection REG216 / REG216 Classic 1MRB520004-Ben Page 20 Technical data (cont´d) ABB Switzerland Ltd Power Technology Systems Table 26: Dead machine protection (51, 27) Features: • Quick separation from network at accidental energization of generator (e.g. at standstill or on turning gear) • Instant overcurrent measurement • Voltage-controlled overcurrent function e.g. blocked at voltage values >0.85 UN This function does not exist in the library, it must be combined from the voltage current and time function Settings: Voltage 0.01 to 2 UN in steps of 0.002 UN Reset delay 0 to 60 s in steps of 0.01 s Current 0.02 to 20 IN in steps of 0.02 IN Delay 0.02 to 60 s in steps of 0.01 s Table 27: 100% Stator earth fault protection (64 S) Features: • Protection of the entire stator winding, including star points, even at standstill. Works also for most of the operating conditions. • Also suitable when 2 earthings (groundings) are in the protection zone • Continuous supervision of the insulation level of the stator • Based on the earth (ground) voltage displacement principle and calculation of the earth (ground) fault resistance • Alarm and tripping values are entered, resp. measured and displayed in kΩ • Type of earthings (groundings): - star point earthing with resistors (requires REX011) - star point earthing with grounding transformer (requires REX011-1) - earthing transformers on generator terminals (requires REX011-2) Settings: Alarm stage 100 Ω to 20 kΩ Delay 0.2 s to 60 s Tripping stage 100 Ω to 20 kΩ Delay 0.2 s to 60 s RES 400 Ω to 5 kΩ Number of star points 2 RES-2. starpoint 900 Ω to 30 kΩ Reset ratio 110% for setting values of ≤10 kΩ 120% for setting values of >10 kΩ Accuracy 0.1 kΩ to 10 kΩ: <±10% 0 to 100 Ω, 10 kΩ to 20 kΩ: <±20% Starting time 1.5 s Functional requirements: - max. earthing current I0 <20 A (recommended I0 = 5A) - stator earthing capacity 0.5 µF to 6 µ
Contact Us
- Xiamen xiongba e-commerce Co., Ltd
ABB | EPRO | PROSOFT | NI |
REXROTH | Schneider | Miscellaneous brand | EMERSON |
SEW | SIEMENS | GE | SST |
A-B | TRICONEX | WATLOW | WOODWARD |
YAMATAKE | YOKOGAWA | HONEYWEL | BENTLY |
FOXBORO | FSC | ENTERASYS | HIMA |
TRIPLEX |
- 3HNA024871-001 Spraying robot module Industrial robot
- IS200TRPAH2AHE Turbine control system
- KDB-FT1600 sensor Have energy management
- M2004HW Controller module Power supply can be managed
- RAC2.2-200-460-A00-W1 Spare parts module
- CG6060/32-4TE1 Communication module Realize automatic control of equipment
- IS220PDIIH1B 336A5026ADP1 Thermocouple input module
- PPC380AE01 HIEE300885R0001 Input module
- IS220PAICH2A Analog input/output module Detects external switching input
- DS200TCEAG1ACB Communication module Support data reading
- IC698CRE030 Built-in Ethernet port Automatic induction switch
- CP451-50 Processor module
- IC698CRE040-HN CPU module microprocessor
- Supports 4G Communication Power Grids Automation Industrial IoT Protocol Gateway
- DLT645 IEC104 to MQTT Power Grid IoT Gateway for Data Collection and Transparent Transmission
- RJ45 Ethernet Port DLT645 IEC104 to OPC UA Grid Protocol Converter
- Support SNMP V1/V2 DLT645 IEC104 to Modbus Distribution Protocol Gateway
- MU-TAMT02 HONEYWELL BATTERY EXTENSION MODULE
- 204-450-000-002 IQS452 Meggitt Vibro-Meter New in stock
- 204-450-000-001 IQS452 Meggitt Vibro-Meter New in stock
- TK-PPD011 HONEYWELL Battery Extension Module
- KJ3204X1-BA1 Emerson DeltaV Module High-Side Series 2 Card
- SD-98790 HARRIS Digital Input Board
- 204-677-000-003 TFM677 Meggitt Vibro-Meter New in stock
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-