Brand Name: | GE | Place of Origin: | China | Model Number: | IS200SRTDH2ACB |
Product Description
Brand: GE
Type: IS200SRTDH2ACB
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Press the “YES” key to enable this mode or the “Scroll Down Arrow” to step to the mode desired. (Refer to Figure 4-8). 6a. HP Valve to Min—Enabld, Min Curr Adjust * XXX.XX—Press YES to force the actuator output to the minimum stop. The message will display ‘At Min’ and the actuator output current will move to its minimum setting. The minimum current value can be adjusted only when the ‘at sign’ (@) is on the bottom line of the display. Press the SELECT key to move the @ symbol between the top and bottom lines. Press the ADJ UP or DOWN keys to change the 0% actuator current level. Press the SCROLL DOWN ARROW to step the next desired mode, or the “CLEAR” key twice to save changes, and exit Calibration mode. 6b. HP Valve to Max—Enabld, Max Curr Adjust * XXX.XX—Press YES to force the actuator output to the maximum stop. The message will display ‘At Max’ and the actuator output current will move to its maximum setting. The maximum current value can be adjusted only when the ‘at sign’ (@) is on the bottom line of the display. Press the SELECT key to move the @ symbol between the top and bottom lines. Press the ADJ UP or DOWN keys to change the 100% actuator current DOWN ARROW to step the next desired mode, or the “CLEAR” key twice to save changes and exit Calibration mode. 6c. Manually Adjust—Enabld, Stroke HP Valve XXX.XX—Press the ADJ UP, ADJ DOWN keys from this screen to move the HP valve’s output current between 0-100% at a 5%/second rate. This allows both the actuator and valve to be tested for binding, play, resolution, linearity, and repeatability. Press the “YES” key at any time to allow a setting to be directly Entered. The message will display ‘Manual’ when the ENTER mode is allowed. When in the ‘Manual’ mode, press the “ENTER” key, followed by the setting desired then press the “ENTER” key again. This will step the actuator output to a specific position instantly. Press the “ADJ UP/DOWN” or “No” keys at any time to switch back to the “Enabld” mode. When calibration is complete, 0 to 100% valve position as displayed by the 505E must equal 0 to 100% actual valve travel. Press the SCROLL DOWN ARROW to step the next desired mode, or the “CLEAR” key twice to save changes and exit Calibration mode. 6d. LP Valve to Min—Enabld, Min Curr Adjust * XXX.XX—Press YES to force the actuator output to the minimum stop.
The message will display ‘At Min’ and the actuator output current will move to its minimum setting. The minimum current value can be adjusted only when the ‘at sign’ (@) is on the bottom line of the display. Press the SELECT key to move the @ symbol between the top and bottom lines. Press the ADJ UP or DOWN keys to change the 0% actuator current level. Press the SCROLL DOWN ARROW to step the next desired mode, or the “CLEAR” key twice to save changes and exit Calibration mode. 6e. LP Valve to Max—Enabld, Max Curr Adjust * XXX.XX—Press YES to force the actuator output to the maximum stop. The message will display ‘At Max’ and the actuator output current will move to its maximum setting. The maximum current value can be adjusted only when the ‘at sign’ (@) is on the bottom line of the display. Press the SELECT key to move the @ symbol between the top and bottom lines. Press the ADJ UP or DOWN keys to change the 100% actuator current level. Press the DOWN ARROW to step the next desired mode, or the “CLEAR” key twice to save changes and exit Calibration mode.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
- For Building Data Acquisition HVAC Monitoring and Control BACnet/IP IO Module
- Supports VPN and TLS/SSL Data Encryption Flexible EdgeIO Controller
- 800PP846A Operation panel Provides greater visibility into the process
- TRICONEX 3721 Communication module Multiple sensors can be connected
- PM150V08 3BSE009598R1 High performance processor module Multiple control tasks can be handled simultaneously
- MS-NAE5510-3 Ethernet-based monitoring devices Higher data transfer rate
- triconex 3625C1 Digital output module The flexibility of the control system is improved
- triconex 3636R Automatic control module Supports multiple communication protocols
- KUC711AE101 3BHB004661R0101 Digital input module Ability to detect input signals in time
- CI541V1 3BSE014666R1 Interface module Connect and transfer data
- IS220PDIAH1B Turbine control PCB board
- UTV-F2500HA Manipulator controller Remote manipulator
- triconex 4329 Network communication module Ethernet (802.3) port
- Programmable Logic Controller MQTT IO Module for Distributed Data Acquisition and Control Systems
- IS215UCVEH2AB Standard mark VI controller Ethernet cable
- DS200SIOBH1ACA I/O control board There are 6 switches in each block
- DS200SIOBH1AAA I/O control board Equipped with an LED
- DS200SIOBH1ABA I/O control board Has 20 jumpers
- PP881 3BSE092978R1 Touch display module Ability to respond quickly to user operations
- IC697CPX928 Central processing unit Single slot chassis
- IS200TREGH1BEC Emergency turbine protection plate Provides negative electrode function
- F8627X Spare parts module
- SC520M 3BSE016237R1 Industrial automation module Realize automatic control of production line
- 5SHY3545L0009 3BHB013085R0001 Industrial control spare parts module The low-pass voltage drop of thyristor is realized
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-