PFTL201C 10KN/20KN/50KN ABB Tension controller head

PFTL201C 10KN/20KN/50KN ABB Tension controller head


Our Email: 2235954483@qq.com

contact number:13313705507

contacts:HE


The following diagram shows the limit curve for Tmax T2L160, In160 circuit-breaker.

The x-axis shows the effective values of the symmetrical prospective short-circuit

current, while the y-axis shows the relative peak value. The limiting effect can

be evaluated by comparing, at equal values of symmetrical fault current, the

peak value corresponding to the prospective short-circuit current (curve A) with

the limited peak value (curve B).

Circuit-breaker T2L160 with thermomagnetic release In160 at 400 V, for a fault

current of 40 kA, limits the short-circuit peak to 16.2 kA only, with a reduction

of about 68 kA compared with the peak value in the absence of limitation (84 kA)

Considering that the electro-dynamic stresses and the consequent mechanical

stresses are closely connected to the current peak, the use of current limiting

circuit-breakers allows optimum dimensioning of the components in an electrical

plant. Besides, current limitation may also be used to obtain back-up protection

between two circuit-breakers in series.

In addition to the advantages in terms of design, the use of current-limiting

circuit-breakers allows, for the cases detailed by Standard IEC 60439-1, the

avoidance of short-circuit withstand verifications for switchboards. Clause

8.2.3.1 of the Standard “Circuits of ASSEMBLIES which are exempted from

the verification of the short-circuit withstand strength” states that:

“A verification of the short-circuit withstand strength is not required in the

following cases.

For ASSEMBLIES protected by current-limiting devices having a cut-off current

not exceeding 17 kA at the maximum allowable prospective short-circuit current

at the terminals of the incoming circuit of the ASSEMBLY.

...”

The example above is included among those considered by the Standard: if

the circuit-breaker was used as a main breaker in a switchboard to be installed

in a point of the plant where the prospective short-circuit current is 40 kA, it

would not be necessary to carry out the verification of short-circuit withstand.

Product Tags: PFTL201C 10KN , PFTL201C 20KN , PFTL201C 50KN

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Xiamen, Fujian, China

Recommended Categories

Explore top categories and find suppliers for your specific needs