NDCU-12C NDCU-12CK
- 147 Piece / Pieces per Month
- T/T
- 1 days
Product Details
Brand Name: | ABB | Place of Origin: | China | Model Number: | NDCU-12C NDCU-12CK |
Product Description
Brand:ABB
Type:NDCU-12C NDCU-12CK
Origin: the Swiss
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Analog Outputs Applications using the 505E analog outputs must have the desired analog value assigned or configured to a specific output. There is a choice of six possible 4– 20 mA output drivers of which to use to display a parameter externally. The analog output connections for the 505E are shown in Figure 2-7. All 505E analog outputs can drive into a maximum of 600 Ω. Refer to Chapter 4 of this manual for a complete list of programmable analog output options. Actuator Outputs The two actuator output drive currents can be programmed to interface with Woodward Governor Company actuators (typically 20–160 mA drive currents) or non-Woodward actuators (4–20 mA drive currents). Each actuator output can be individually configured to interface with Woodward or non-Woodward type actuators. Actuator drive current is selected in the Program Mode. Maximum impedance for each 4 to 20 mA actuator output driver is 360 Ω (actuator impedance + wire resistance). Maximum impedance for each 20 to 160 mA actuator output is 45 Ω (actuator impedance + wire resistance). Dither is available for either output. Each actuator driver senses the drive current to allow over- and under-current shutdowns. Refer to Table 4-1 for driver details. In addition, an eleven (11) point actuator linearization adjustment curve is available through the Service Mode for each actuator output (see Service Mode adjustments in Volume 2). Relay Outputs There are eight relay outputs available from the 505E. All relay contacts are Form C type contacts. For relay load ratings, refer to Appendix A in Volume 2. NOTE Before installation verify that the 505E’s relay contacts meet the power requirements of the circuit with which it is being interfaced. Interposing relays are required, in cases where the interfaced circuit demands relay contacts with a higher power rating.
If interposing relays are required, it is recommended that interposing relays with surge (inductive kick-back) protection be used. Improper connection could cause serious equipment damage. Two of the eight relay outputs available are dedicated to a function and are as follows: • Shutdown relay—de-energizes for any shutdown condition • Alarm relay—energizes for any alarm condition The remaining six relays can be programmed to energize upon a function change of state or an analog value level. Applications requiring programmable relay outputs must have the desired switch condition or specific analog value assigned to them. Refer to Chapter 4 of this manual for a complete list of programmable relay output options.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Popular Searches
- lightning conductor
- Copper Lightning Rod
- Lightning Rod Clamp Earth Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- Air Blower Electrostatic Eliminator
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
Recommended Products
- phase loss protector Precision three-phase 380V water pump motor intelligent protector With fault code prompt
- 380V 3 phase intelligent digital display water pump/motor circuit breaker phase loss protector 40A 100A overload phase loss motor protector
- AB 1769-PB4 COMPACTLOGIX 4A POWER SUPPLY 24V DC
- AB 1769-PA2 COMPACTLOGIX 2A POWER SUPPLY 120/240V AC
- AB 1769-OW8I COMPACTLOGIX 8DO 5-265V AC/5-125V DC RELAY MODULE ISOLATED
- AB 1769-OW8 COMPACTLOGIX 8DO 5-265V AC/5-125V DC RELAY MODULE
- AB 1769-OA16 COMPACTLOGIX 16DO 85-265V AC MODULE
- AB 1769-L32E COMPACTLOGIX L3 PROCESSOR ENET 750KB
- AB 1769-L32C COMPACTLOGIX L3 PROCESSOR CNET 750KB
- AB 1769-L32C COMPACTLOGIX L3 PROCESSOR CNET 750KB
- AB 1769-L18ER-BB1B COMPACTLOGIX 5370-L1 PROCESSOR 16DI/16DO 512KB
- AB 1769-IA16 COMPACTLOGIX 16DI 79-132V AC MODULE
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile