Home > Health & Medicine > IVD > Hot Selling 50Pcs Diabetes One Touch Select Blue Household Blood Glucose Meter Test Strips

Hot Selling 50Pcs Diabetes One Touch Select Blue Household Blood Glucose Meter Test Strips

Hot Selling 50Pcs Diabetes One Touch Select Blue Household Blood Glucose Meter Test Strips photo-1
Negotiable MOQ: 1000 Pieces (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Business Type:
Business Service (Transportation, finance, travel, Ads, etc)
Year Established:
2020
Annual Export Value:
US$2.5 Million - US$5 Million
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.

Contact US

Email:info@launch-electric.com

Product Description

Our home  Guilin Renke Medical Technology Development Co., Ltd.


blood glucose test strips

Technical specifications

Product: Test Strips for Blood Test: 50/100-unit box.

Test method Glucose Oxidase biosensor

Test result range 10 ~ 600 mg / dL (0.6 ~ 33.3 mmol / L)

Test time required 5 sec.

Blood amount required 0.8μℓ

Blood reference type Plasma reference

Measuring unit mg / dL, mmol / L

 packaging:a bottle(25T vials) or (50T vials)

Authentication:ISO/GXFDA

  OEM/ODM

Storage and Handling
* Store the test strip package in a cool,dry place not above30℃(86℉).Keep away from direct sunlight and heat.Do not refrigerate.
* Store your test strips in their original vial only,do not transfer them to a new vial or any other container.
* After removing a test strip from the vial,immediately replace the vial cap and close it tightly.
* Use each test strip immediately after removing it from the vial.
* Write the discard date on the vial label when you first open it.Discard remaining strips 3 months after first opening the vial.
* Do not use test strips beyond the expiration date printed on tha package since they may cause inaccurate results.

WARNING:Keep the test strip vial away from children;the cap is a choking hazard.Also,the cap or vial may contain drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation.

Precaution to Obtain Accurate Results
* Code the Blood Glucose Meter to match the code number printed on the test strip vial.
* Never make significant changes to your diabetes control program or ignore physical symptoms without speaking with your healthcare professional.

Quality Control:Checking the System
Do a Control Solution Test:
* When you begin using a new vial of test strips
* At least once a week
* Whenever you suspect that the meter or test strips are not working properly
* If you drop the meter

When control solution is applied to the top edge of the test strip,you should get results within the espected range printed on the
test strip vial.If control solution test results fall outside range,repeat the test.Results that fall outside the range may be
caused by:
* Error in performing the test
* Failure to shake the control vial well enough(must shake vigorously)
* Expired or contaminated control solution
* Improper coding of the meter
* Test strip deterioration
* Meter malfunction
* Control solution that is too warm or too cool
* Failure to discard the firstg drop of control solution

LIMITATIONS
Test Strips give accurate results when the following limitations are observed:
* The test strips should not be used for the testing of newborns.
* The test strip are for single use only.Do not reuse.
* The test strips are specific to D-glucose and do not resct to other sugars wich may be present in blood.
* Use only fresh capillay whole blood.Do not use serum or plasma.

Healthcare professionals-please additional limitations:
* Fresh capillary blood may be collected into heparin-containing test tubes if the blood is used within 10 minutes.Do not use other anticoagulants or preservaties.
* Interferences:Acetaminophen,salicylates,uric,ascorbic acid (vitamin C)and other reducing substances(when occurring in normal blood or normal therapeutic concentrations)do not significantly affect results.However,abnormally high concentrations in blood  may cause inaccurately high rsults.
* Patients undergoing oxygen therapy may yield falsely lower results.
* Test results may be falsely low if the patient is severely dehydrated,in shock,or in a hyperosmolar state (with or without
  ketosis).Critically ill patients should not be tested by blood glucose meters.

·Lipemic samples:Cholesterol leves up to 600mg/dL(15.5mmol/L)and triglycerides up to 400mg/dL(4.5mmol/L)do not affect the results.



Product Tags: Hot Selling 50Pcs Diabetes One Touch Select Blue Household Blood Glucose Meter Test Strips , Selling 50Pcs Diabetes One Touch Select Blue Household Blood Glucose Meter Test Strips , Blood Glucose Meter Test Strips

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Business Service (Transportation, finance, travel, Ads, etc)
Year Established
2020
Annual Export Value
US$2.5 Million - US$5 Million
Port of Shipment
shanghai, tianjin, guangzhou