Power quality devices 12v active power harmonic filter ahf panel cancels harmonic currents
- 1000 per Month
- T/T Credit Card
- Three phase medium voltage 750kvar automatic power factor correction cab with harmonic filter
- 1000 kvar medium voltage power factor correction cabrini common facilities solution
- 400v 3phase 150 200kvar balance active harmonic filter(ahf) ahf wallmount ahf cabinet mount
- 240V and 480V 3 a single phase harmonic filter reduce system downtime
- Low voltage active power filter apf fast compensation for harmonic filtering circuit
- 100a apf 3ph 4 wires wall mount active harmonic filter system
Product Description
Power quality devices 12v active power harmonic filter ahf panel cancels harmonic currents
Description
The wide application of nonlinear power equipment produces a lot of distorted current harmonics, which cause harmonic voltage when flowing in power grid. This harmonic pollution threatens the safety and stability of power system seriously. Together with electromagnetic interference, power factor reduction, are the three major public hazards for power system.
Active power filter(APF/AHF for short) is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave(can filter 2nd to 50th harmonic interference completely), reactive power, and 3 phase load unbalance.APF is connected in parallel in power grid, to detect the harmonic wave in power grid in real time, generate the reverse-phase compensation current through the converter, and dynamically filter the harmonic wave in power grid. The operation of APF is unaffected by power grid structure and load type, and it will not produce harmonic oscillation with the system, thus perfectly realizing harmonic wave control of various loads. APF can also realize dynamic reactive compensation, and control the capacitor switching, to improve the power factor of power grid. Meanwhile, APF has the function of controlling the 3 phase load current unbalance, thus comprehensively solving various power quality problems with power grid.
Installation method
Working principle
Application Site
Active Harmonic Filtering technology can be applied to wide range of industrial or commercial environments where good power quality is essential. Active Harmonic Filters have been used for the processes that use variable speed drives (VSD), fast fluctuating loads such as welding machines, uninterrupted power supply (UPS) systems and DC load, single phase loads such as lighting and computers as well as electric arc furnaces and rolling mills.in addition,applications in data centers & IT, hospitals and laboratories,shopping malls,wind and solar farms,metro stations,steel industry,pharmaceutical industry etc.
Advantages
1. It can filter out harmonic currents below 2~50 times at the same time, so that the current distortion rate of the power supply side is THDI<3% at full load, and THDI<4% at half load;
2. Working mode: filter harmonics, reactive power compensation, filter harmonics and reactive power compensation, and set the priority of functions;
3. Using sliding window iterative DFT detection algorithm, fast calculation speed, instantaneous response time is less than 0.1ms, device compensation full response time is less than 10ms;
4. The original adaptive current average value control algorithm is adopted to narrow the frequency spectrum of the high-frequency harmonics generated by the IGBT of the device itself, and the output current distortion rate is less than 2.5%;When the three-phase load current is unbalanced, the filter can normally compensate and eliminate the unbalance phenomenon;
5. Using reliable current limiting control links, when the harmonic current in the system is greater than the device capacity of the active filter, the filter can automatically limit the current at 100% capacity output.
6. The switching device adopts the IGBT of the international famous brand, which is extremely reliable, combined with the unique active clamping technology, to ensure that the IGBT will not have an over-voltage explosion tube failure under any extreme conditions.
7. The main circuit adopts 3H bridge type three-level structure, the output waveform quality is high, and the switching loss is lower.
8. Adopting high-definition touch screen, easy to operate, real-time display system and device operating parameters on the screen, with fault alarm and recall function;
9. The output filter adopts the LCL structure, which not only prevents the high-order harmonics generated by the IGBT high-frequency switch during ZBAPF compensation from being injected into the grid, the compensation effect is better, and it is also adaptable in any on-site grid system impedance, resonance will not occur, ensuring the safety of the installation;
10. Use Xilinx's military-grade FPGA for centralized control. The FPGA clock frequency can be up to 200MHz. There are 84 hardware DSP units inside. DSP runs in parallel. The operation speed is much higher than that of a single DSP control method. The communication delay is small and the response speed is faster. The program needs to be called, and the anti-interference ability is strong, and there will be no program runaway failure.
11. 12 devices can be connected in parallel and only one FPGA controller can be used for centralized control.
12. The input end of the active filter is equipped with a reliable lightning surge protection device. When a lightning wave occurs, the protection device plays a protective role and does not damage the equipment.
Technical Parameters
ZBAPF |
3 phase 3 wire |
3 phase 4wire |
Rated compensation current |
50A—400A |
50A—400A |
power input |
||
Working voltage (V) |
400V(-20%~+15%) |
400V(-20%~+15%) |
working frequency |
690V(-20%~+15%) |
50/60 |
Performance |
||
Filtering ability |
THDi<3%(Rated) |
THDi<3%(Rated) |
Filter range |
2~50 harmonics |
2~50 harmonics |
Single harmonic compensation rate adjustment |
Compensation current limit for each harmonic |
Compensation current limit for each harmonic |
Transient response time |
<100us |
<100us |
Full response time |
<10ms |
<10ms |
Active power loss |
<3%Rated |
<3%Rated |
Correct three-phase imbalance |
Yes |
Yes |
Reactive power compensation function |
Yes, power factor can be set |
Yes, power factor can be set |
Overload protection |
Automatic current limit at 100% rated output |
Automatic current limit at 100% rated output |
Operating frequency |
20KHz |
20KHz |
Display and operation |
||
UI |
5.7 inch touch screen |
5.7 inch touch screen |
Display state |
Grid parameters such as current and voltage |
Grid parameters such as current and voltage |
communication |
Modbus,RS485,RS232 |
Modbus,RS485,RS232 |
Product configuration |
||
Installation method |
Wall hanging, cabinet |
Wall hanging, cabinet |
Environmental conditions |
||
Ambient temperature |
-10℃~40℃ |
-10℃~40℃ |
Storage environment |
-40℃~65℃ |
-40℃~65℃ |
Relative humidity |
Maximum 95%, no condensation |
Maximum 95%, no condensation |
Altitude |
Below 1000 meters |
Below 1000 meters |
Related products
Contact Us
- Strong Power Electric Co.,Ltd.
- AC three phase harmonic shunt filters reduce harmonics in power systems
- 300kvar 150kvar 50-60 hz three phase dynamic reactive compensation harmonic active filter apfc panel
- Three phase power quality 380v 4 wire 60a active power filter load harmonic filter harmonic correction
- 400v 3phase 400a active harmonic filter price list dynamic reactive power compensation solution
- Steel mill power system active power factor rectifire harmonic mitigation harmonic reduction filter
- Harmonic correction system power quality enhancement active harmonies filters apfc controller cabinet
- 400v 3phase 150a active harmonic filter panel complete cabinet reduce harmonic current
- Industrial level 200a ahf power harmonic filter compensation power distribution equipment
- Igbt based harmonic filter resolve power quality problems cancels the load generated current harmonics
- AHF active harmonic filter harmonic compensation cabinet APF active power filter reduce harmonic current price
- Custom size 30-600a flexible stand-alone & modular active filter harmonics ahf design
- Adjustable dynamic compensation filters active harmonic modular correct current waveform
- 30a wall mounted ahf active harmonic filter cabinet intelligent automatic system reactive current
- Dynamic real time power factor correction active harmonic filter panel for power quality improvement
- Three phase module design apf active power harmonic filter to protect motor efficiency
- 380v 100a power distribution active harmonic filter module real time power factor correction
- Dynamic harmonic mitigation low voltage active harmonic power filter ahf module 400v
- China supply 3 phase 150a active harmonic filter ahf module for energy saving
- Hot sale active power filter module 220v 50a apf active harmonic filter ahf supplier
- 220v 3 phase 4 wire apfc 100a apf harmonic elimination active harmonic filter solutions
- Best price rack mounted harmonic filter active ahf module for harmonics control
- 100a wall active harmonic filter ahf module for power factor improvement
- Active harmonic filter manufacture 100a power quality device with function of active load balancing
- 400v 3 phase ahf module distribution active harmonic filter for saving electricity bills
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-