Home > Products > Other testing equipment > TP-800B microcomputer rapid sulfur analyzer in coal
TP-800B microcomputer rapid sulfur analyzer in coal
- 1000 per Month
- T/T Credit Card
- MUF-300 energy-efficient intelligent integrated muffle furnace
- Nitrogen Drying Oven NDY-1A
- Transformer oil BDV tester IEC156 ASTM D1816 ASTM D877
- 0.01 to 1000 gram Digital Display Electronic Weight Balance
- Portable transformer testing equipment turns ratio meter /High accuracy ttr
- ASTM D217 Lubricating OIL Grease Asphalt Cone Penetrometer
Product Description
Application:
1. The dual-machine dual-system control is adopted to make the instrument work more stable. The compatibility between the microcomputer and the single chip system is good. The test software fully supports the Windows platform. The standard RS232 serial interface is used between the microcomputer and the single-chip system. It has the characteristics of simple wiring, reliable transmission, long transmission distance and low failure rate. English menu-style operation interface, easy to operate and easy to learn.
2. The whole test process is automatically completed by the microcomputer control system, and can also be separated from the characteristics of the microcomputer work. It meets the requirements of GB/214-2007 "Method for determination of total sulfur in coal".
3. The product adopts color touch screen as human-computer interaction component. It is easy to adjust and display intuitively during the experiment. It has real-time self-diagnosis fault and fault handling step prompt solution.
4. The measurement time can be automatically determined according to different coal samples, about 5min. The system error is directly corrected by software, and the measurement result is superior to the national standard, with good repeatability and high accuracy.
5. Adopt advanced PID (proportional, differential, integral) temperature control algorithm, accurate temperature control, high temperature control accuracy and fast heating rate. It adopts non-contact switch with hardware over-temperature protection and electrolyte anti-backflow measures, which is safe and reliable.
6. The instrument program controls automatic temperature rise, temperature control, sample delivery, sample removal, electrolysis, calculation, and the results are automatically saved, printed, and the work done by the operator is just a sample. The measurement results can be stored for a long time and can be queried and printed. The software uses a dynamic graphical interface for intuitive and easy operation.
7. The system places the high temperature furnace, magnetic stirrer, air purifying device, electrolytic cell, automatic sample feeding mechanism and single chip control circuit in the same chassis reasonably, so that the whole system is beautiful, small in size, and the system is convenient to place and connect. The system operation and daily maintenance are simple.
Technical parameter
Sulfur measurement range 0.01 to 60%
Analysis time 3~9min system automatic judgment control
Heating rate ≤25min
High temperature zone length ≥90mm
Electrolytic cell volume 450ml
Power source 220V±20% 50Hz
Weight about 50kg
Power supply AC220V±22V 50Hz±1Hz;
Temperature resolution 1 ° C
Heating range room temperature ~ 1250 ° C ± 2 ° C
Working furnace temperature 1150 ° C ± 2 ° C (adjustable temperature as needed)
Sulfur measurement accuracy 0.0001%
Carrier gas flow rate 1000ml/min
Power ≤3KW
Ambient temperature room temperature ~ 40 ° C
Packing: standard export wooden case.
Delivery method: Usually delivered by express (TNT, DHL, UPS etc), but air freight or other way are available if need.
Contact Us
- Chongqing Top Oil Purifier Co., Ltd
- High precision portable IF-180 hand held oil in water analyzer
- Transformer oil bdv testing kit DYT Series with IEC156 IS6792 ASTM D1816 ASTM D877
- Portable digital liquid ph tester with high accuracy
- TPD-2G large color LCD moisture analyzer Karl Volumetric Water Content Tester
- Digital testing equipment ratio meter for transformer oil / Portable ttr
- Digital ttr meter transformer turns ratio tester
- transformer oil dissolved gas analyzer DGA 2013 - 1
- Wide tested moisture range high accuracy karl fischer moisture analyzer
- Substation essential test set transformer turns ratio tester TPVA-402
- Mini size online measurement type transformer oil water content testing equipment
- Digital Automatic Laboratory Equipment Diesel Fuel Oil / Lube Oil Cloud Point & Pour Point Tester with ASTM D97 Standard
- Portable Liquid PH tester Digital to test PH value from 0 to 14
- Transformer common tester Turn Ratio Test machine TPOM-901
- ACD-30001 Automatic Transformer Oil Acidity Test Kit
- Fully Automatic Transformer Oil Test Equipment to Test Breakdown Voltage / Portable Insulation Oil Dielectric Strength Tester
- Portable Digital /Laboratory Equipment Acidity Measuring Device
- Lab Station Portable TTR Tester / Transformer Turns Ratio Meter
- TP-226 Comparative Colorimeter (Lovibond Colorimeter)
- High Accuracy Diesel Fuel Test Kit ASTM D97 Pour Point Tester
- Online Water Content Testing equipment oil moisture content meter TPEE
- High Speed Halogen Moisture Content Analyzer Model RP-104
- Portable Automatic Interfacial/Surface Tension Analyzer (IT-800P)
- TOFT Transformer Load and No-load Characteristic Testing Equipment
- Coal Ash Volatiles Fixed Carbon Analyzer Advanced Coal Laboratory Equipment
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Testing Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-