Acrel APM800 Three Phase Multifunction Energy Meter/smart Digital Panel Power Meter CE
General
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.
Technical Parameters |
Index |
|||
Signal |
Electrical network |
Three-phase three-wire, three-phase four-wire, see the wiring diagram; |
||
Frequency |
45~65Hz; |
|||
Voltage |
Rated value:AC 100V、110V、400V、690V; |
|||
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second; | ||||
Power consumption: | ||||
Current |
Rated value: AC 1A, 5A, support 4 mm2 line access; |
|||
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second; | ||||
Power consumption: | ||||
Measurement accuracy |
Voltage、current and power |
class 0.5s/class 0.2s (APM800、APM810/APM801) |
||
Active power |
class 0.5s/class 0.2s (APM800、APM810/APM801) |
|||
Reactive power |
class 2 |
|||
Harmonic |
1%(2rd~42nd)、2%(43rd~63rd) |
|||
Switch inputs |
Dry contact inputs, built-in power supply; |
|||
Relay outputs |
Contact type: open contact in main part, changeover contact in module; Contact capacity:AC 250V/3A DC 30V/3A; |
|||
Pulse output of energy |
Output mode: Optocoupler pulse with open collector; Pulse constant:4000(5A)、8000(1A) imp/kWh; |
|||
Analog outputs |
DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω; |
|||
Analog inputs |
DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V iutput, accuracy class 0.5% |
|||
Storage card |
Standard Capacity:4G,TF Card Up to 32G Capacity; |
|||
Communication |
RS485 interface/Modbus-RTU protocol and DLT645 protocol Profibus-DP interface/Profibus-DP protocol; RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols; |
|||
Power supply |
Working range: AC/DC 85V~265V or AC/DC 115~415V(P2); Power consumption: Power consumption of the main part ≤ 15VA; |
|||
Safety |
Power frequency withstand voltage |
The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min; The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min; The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min; |
||
Insulation resistance |
Inputs、outputs to the shell>100MΩ; |
|||
Electromagnetic compatibility |
Meet IEC 61000 standard (Level 4); |
|||
Protection level |
Display panel IP52 |
|||
Environment |
Operating temperature: -20 °C ~ +65 °C; Storage temperature: -20°C~+70°C; Relative humidity: ≤95% without condensation; Altitude: ≤2500m; |
|||
Standards |
IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-30 |
Environmental Testing-Part 2-1:Tests Test A:Cold IDA Part 2-1:Tests Test B:Dry heat Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h) |
||
IEC 61000-4 |
Electromagnetic compatibility-Testing and measurement techniques |
|||
IEC 61557-12 |
Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c –Equipment for testing,measuring or monitoring of protective measures- Part12: Performances measuring and monitoring devices(PMD) |
|||
IEC 62053-22 |
Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s) |
|||
Send Inquiry to This Supplier
You May Also Like
-
Acrel AM2SE High Quality Smart Automatic RS485 Communication Thermal Overload Switch Transformer Protection RelayUS$ 207.4 - 207.4MOQ: 1 Piece
-
Acrel APM800 Class 0.5 Three Phase Multifunction Power Meter/smart Programmable Energy MeterUS$ 254.8 - 254.8MOQ: 1 Piece
-
Acrel APM800 Three Phase Multifunction Panel Energy Meter for Full Power Parameter MeasuringUS$ 254.8 - 254.8MOQ: 1 Piece
-
Acrel APM Series 3P3W 3P4W 0.5s Class 4-20mA Output Secure 3 Phase Power Monitoring Energy MeterUS$ 254.8 - 254.8MOQ: 1 Piece
-
Acrel APM Series Accuracy Smart Multifunction Energy Meters for Comprehensive Monitoring of the Quality of Power Supply Network With CE CertificationUS$ 254.8 - 254.8MOQ: 1 Piece
-
Acrel APM800 Three Phase RS485 Modbus-RTU Communication LCD Energy Management Multifunction MeterUS$ 254.8 - 254.8MOQ: 1 Piece
-
Acrel APM800 3 Phase Digital Multifunction Panel Power Meter Power Fail Over Voltage Event Record EthernetUS$ 248.5 - 248.5MOQ: 1 Piece
-
Acrel APM Series Bidirectional 3P Power Meter for Full Electrical Parameters Measuring With LCD DisplayUS$ 254.8 - 254.8MOQ: 1 Piece
-
Acrel APM800 Smart Electrical Meter With Analog Signal 8 Channel 4-20mA Input and 4 Channel 4-20mA Output Energy MeterUS$ 254.8 - 254.8MOQ: 1 Piece
-