SXHGQ-H Automatic High-voltage Three-phase Combined
SXHGQ-H automatic high-voltage three-phase combined transformer calibration station, also known as transformer calibration station, transformer calibration device, transformer calibration device, transformer detection device, SXHGQ-H automatic
The combined transformer verification device changes the current traditional single-phase inspection method, realizes the verification of the combined transformer, meets the requirements of the current national standards and industry standards (test guidelines), and is easy to implement
Inspection, it does not require multiple wiring tests in the current single-phase method, which can save a lot of manpower and material resources and improve work efficiency. It consists of a combination of transformer error data management software, transformer calibrator,
It is composed of voltage and current load box, electronic power source and standard transformer. RS485 communication is adopted between the components to realize the automatic verification of the multi-phase voltage and current of the three-phase combined transformer in turn.
It is suitable for measurement and test centers of power grid companies, power management and measurement departments of power supply companies, national measurement and test institutions at all levels, and large industrial and mining enterprises.
Measurement object Low voltage transformer, high voltage transformer, metering box
Measurement limit Current primary: 5A~1000A Current secondary: 5A, 1A
Voltage once: 6kV~35kV Voltage twice: 200V, 100V, 100 V√3, 100V/3
Combined transformer tester
Test range Ratio difference (%): 0.0001~199.9 Resolution: 0.0001%
Angle difference (’): 0.001~999.9 Resolution: 0.001’
Test accuracy level 2.0
In-phase component (f) X=(X×2%+Y×2%±2 words)
Orthogonal component (δ) Y=(X×2%+Y×2%±5 words)
Programmable power supply
Power input AC 220V±10V
Frequency (50Hz±0.5Hz)
Output voltage AC 0~300V
Control method: automatic/manual
Output capacity Current source part 10kVA
Standard current transformer with current booster
Primary current 5A, 10A, 15A, 25A, 30A, 40A, 50A, 60A, 75A, 100A, 150A, 200A, 300A, 400A, 500A
Secondary current 5A 1A (optional)
Accuracy grade 0.05S grade 0.02S grade (optional)
Input voltage 0~250V
Rated capacity 5kVA
Rated load 5VA
Power factor 1.0
Rated voltage 42kV
Standard voltage transformer with booster
Primary voltage 6kV, 6kV/10kV, 10kV/35kV, 35kV
Secondary voltage 100V, 100/V
Accuracy level 0.05, 0.02 level (optional)
Input voltage 0~250V
Rated capacity 0.5kVA
Rated load ≤0.25VA
Power factor 1.0
Rated voltage 42kV
Send Inquiry to This Supplier
You May Also Like
-
100ATransformer DC WindingNegotiableMOQ: 1 Piece
-
50ATransformer DC WindingNegotiableMOQ: 1 Piece
-
40ATransformer DC Winding Resistance TesterNegotiableMOQ: 1 Piece
-
20ATransformer DC WindingNegotiableMOQ: 1 Piece
-
10ATransformer DC WindingNegotiableMOQ: 1 Piece
-
5ATransformer DC Winding ResistanceNegotiableMOQ: 1 Piece
-
Transformer Turns Ratio TesteNegotiableMOQ: 1 Piece
-
IIITransformer On-Load Tap-Changer TesterNegotiableMOQ: 1 Piece
-
Lightning Impulse VoltageNegotiableMOQ: 1 Piece
-
TKBYQ-IIITransformer On-Load Tap-Changer TesterNegotiableMOQ: 1 Piece