Home > Health & Medicine > Medical Equipment > Ventilator > Automatic Change-Over Nitrous Oxide / N2O Manifold Equipment for Medical Gas Pipeline System

Automatic Change-Over Nitrous Oxide / N2O Manifold Equipment for Medical Gas Pipeline System

Automatic Change-Over Nitrous Oxide / N2O Manifold Equipment for Medical Gas Pipeline System photo-1
Automatic Change-Over Nitrous Oxide / N2O Manifold Equipment for Medical Gas Pipeline System photo-2
US$ 1900.00 - 5600.00 MOQ: 1 Set
Key Specifications
Get Latest Price
Business Type:
Manufacturer
Year Established:
2010
Factory Size:
3,000-5,000 square meters
Payment & Shipping
Payment Methods:
Port of Shipment:
Guangzhou, China
Delivery Detail:
15 days

Automatic Change-Over Medical Nitrous Oxide / N2O Manifold System for Medical Gas Pipeline System

Automatic Change-Over Medical Nitrous Oxide Manifold System is usually used in Medical Gas Pipeline System as main Nitrous Oxide source equipment.

The medical gas, Nitrous Oxide (N2O) is stored in Nitrous Oxide cylinders, in a high pressure (usally max. 15.0MPa / 150Bar). And cylinders are parallel connected with two pieces of manifold pipes (manifold banks). These two manifold pipes are managed by an Automatic Turn-Over / Change-Over Control Unit. In any time, there is only one manifold pipe is turn-on to Medical Gas Pipeline System, and the medical gas Nitrous Oxide in cylinders with this manifold pipe is supplied to Medical Gas Pipeline System.

As gas supplies, pressure in cylinders reduces. When the cylinder pressure reaching to lowest pressure (set by users), the Automatic Change-Over Control Unit turns over, turn off the low pressure manifold pipe (cylinder bank), and turn on another one, to go on supplying Nitrous Oxide gas to Medical Gas Pipeline System. This operation is done in a short time automatically, to keep Nitrous Oxide gas supplying without breaking down.

Same time, the system alarms to users. Usually, users shall replace the empty cylinders by filled ones. And above steps will repeat automatically, to supply Nitrous Oxide gas to Medical Gas Pipeline System contrinuously.

System is made with three main parts:
1, Automatic Turn-Over / Change-Over Control Unit;
2, Nitrous Oxide / N2O Cylinders;
3, Nitrous Oxide / N2O Cylinders Pipes / Nitrous Oxide / N2O Cylinders Bank;

Specifications:
1, Full enclosed metal Automatic Turn-Over control box, to avoid electromagnetic interference;
2, Big Brass Diaphragm type Nitrous Oxide / N2O Regulator, to ensure a steady flow rate;
3, Digital Displayer for system service status;
4, With Sound / Light alarm system; Network Remote Alarm function optional;
5, Open design for cylinder connecting pipes, for future expansion;
6, Compact structure and reasonable layout;
7, Simple installation and maintenance;
8, 100% passed pressure testing before delivery;


We produce and supply Automatic / Manual Medical Gas Manifold System of other medical gas, such as Vacuum, Medical Air, Surgical Air, Nitrogen, Carbon Dioxide, etc.;

For more information details, please contact us.

Product Tags: Nitrous Oxide , N2O , Medical Nitrous

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2010
Factory Size
3,000-5,000 square meters
Annual Export Value
US$2.5 Million - US$5 Million