48v 1kw Ceil Fan Drive Test Dynamometer Hair Dryer Outrunn Brushless dc Motor for Electr Surfboard
|
Motor type
|
Output
|
Voltage
|
Load
|
Speed
|
Rated Torque
|
Efficiency
|
|
KW
|
V
|
A
|
RPM
|
N.m
|
%
|
|
|
BLDC1.55-154
|
1.55
|
45
|
40
|
4300
|
3.44
|
86
|
|
BLDC1.8-154
|
1.8
|
60
|
32.6
|
1100
|
15.6
|
92
|
|
BLDC1.85-154
|
1.85
|
24
|
81.5
|
2100
|
8.41
|
92
|
|
BLDC2.7-154
|
2.7
|
60
|
48.9
|
1100
|
23.4
|
92
|
|
BLDC2.8-154
|
2.8
|
60
|
50.8
|
1100
|
24.3
|
92
|
|
BLDC2.8B-154
|
2.8
|
48
|
67.8
|
2600
|
10.3
|
86
|
|
BLDC3.0-154
|
3.0
|
48
|
67.6
|
2650
|
10.81
|
92.5
|
|
BLDC3.0B-154
|
3.0
|
72
|
46.8
|
1850
|
15.5
|
89
|
|
BLDC3.5B-154
|
3.5
|
60
|
69.5
|
1680
|
19.9
|
84
|
|
BLDC4.0-154
|
4.0
|
48
|
90.6
|
2580
|
14.81
|
92
|
|
BLDC5.5-154
|
5.5
|
72
|
85.6
|
3680
|
14.27
|
89.2
|
VIEW MORE PLS CONTACT US >>>



Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.
Send Inquiry to This Supplier
You May Also Like
-
DC Gear MotorNegotiableMOQ: 1 Set
-
High Quality High Pressure Hydraulic MotorNegotiableMOQ: 1
-
for PS2 5000X GEARNegotiableMOQ: 10 Pieces
-
Motorcycle Start Motor for XF125GY , Motorcycle Parts , Motorcycle Starter MotorNegotiableMOQ: 1 Piece
-
Elco Fan Motor(82 Series)NegotiableMOQ: 1000 Pieces
-
Motor Windscreen(ATV Windscreen, Motorcycle Windshield)NegotiableMOQ: 1
-
GE WR 60*10185 DC Evaporator Fan MotorUS$ 5 - 10MOQ: 400 Pieces
-
Motor Manufacturing in ChinaUS$ 20 - 500MOQ: 10 Pieces
-
Single Use Thermometer Label for Small Electric Motors / 1 LevelUS$ 63 - 125MOQ: 30 Pieces
-
Pump Electric MotorUS$ 1 - 50MOQ: 100 Pieces