Product Details
Brand Name: | Sansion | Place of Origin: | Hubei, China | Model Number: | SXVLF |
Power: | Electronic |
Product Description
General Information:
VLF Test Sets from 30kV - 90kV with Sine Wave Output
VLF means 'Very Low Frequency' is used in AC hipot test for power cables, transformers, switchgear and other electrical apparatus.
A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.
Features:
√ Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.
√ Portable, easy to move.
√ Large LCD can display waveform clearly, and test report can be printed by built-in printer.
√ The data of current, voltage, and waveform can be sampled at HV side.
√ Over voltage protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.
√ Over current protection: high & low voltage double protection, the precision value of power off protection can be setting at HV side. When the current of LV side is exceeded rated, the control unit will shut itself down within 20ms.
√ HV output protection resistor is built in the booster, not need to connect outside resistor.
√ Adapting high & low voltage closed loop negative feedback control circuit, there is no capacitive rise effect during the output.
Specifications:
√ Accuracy: 3%
√ Voltage +/- peak value error: ≤3%
√ Voltage waveform distortion: ≤5%
√ Working temperature: -10ºC+40ºC
√ Working humidity: ≤85%RH
Model |
Output Voltage/Current |
Load Capacity |
Fuse |
Control Unit |
Booster |
||
Net Dim. |
Net Wt |
Net Dim. |
Net Wt |
||||
SXVLF-30/1.1 |
30KV/29mA |
0.1Hz ≤ 1.1uF |
8A |
28×37×22 |
4 |
33×18×34 |
25 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-40/1.1 |
40KV/29mA |
0.1Hz ≤ 1.1uF |
|
28×37×22 |
4 |
35×20×36 |
45 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-50/1.1 |
50KV/59mA |
0.1Hz ≤ 1.1uF |
|
28×37×22 |
4 |
37×24×39 |
45 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-60/0.5 |
60KV/59mA |
0.1Hz ≤ 0.5uF |
|
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz ≤ 1.0uF |
|||||||
0.02Hz ≤ 2.5uF |
|||||||
SXVLF-70/0.5 |
70KV/59mA |
0.1 Hz, ≤0.5µF |
|
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |
|||||||
SXVLF-80/0.5 |
80KV/59mA |
0.1 Hz, ≤0.5µF |
20A |
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |
|||||||
SXVLF-90/0.5 |
90KV/59mA |
0.1 Hz, ≤0.5µF |
|
28×37×22 |
4 |
33×20×35 |
30+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |
Contact Us
- Wuhan Sansion Power Equipment Manufacturing Co., Ltd.
- Manufacturer 60KV VLF AC Hipot Test Equipment Electric Cable Hipot Test Set / 50KV VLF AC Hipot Tester
- Cable Insulation Test System AC/DC Hipot Dielectric Withstand Test Set For High Voltage Supply
- AC DC High Voltage Test Set / AC Hipot Test Set / Withstand Voltage Test Set
- Manufacturer Oil-Immersed 10 kva 100KV AC/DC Hipot Test Set Power Frequency Voltage Withstand Tester
- AC DC Hipot Test Set Dry Type 100kv Testing Transformer 250kv AC/DC Hipot Tester
- AC DC High Voltage HV Tester Hipot Test Set
- Oil Immersed Type AC DC Insulation Hipot Tester for Cable High Voltage Hipot Testing Transformer Set
- High Capacity 5kva 50kv Oil Type Insulation Testing Transformer AC DC High Voltage Test Set
- 10kVA 100kV Dry Type AC DC Hipot Transformer with Portable Controller
- AC DC Withstand Voltage Test Frequency Power Set Hipot Tester
- 10 kva 100KV AC/DC Hipot Test Set Power Frequency Voltage Withstand Tester Dry Type Testing Transformer
- Chinese Manufacturer AC/DC High Voltage Withstand Hipot Tester/AC DC Hipot Test Set
- AC/DC Hipot Tester, AC/DC Dielectric Test Set
- Automatic DC AC Hipot Tester High Voltage Withstand Test Set High Pot Test Set
- Manual Digital AC/DC Hipot Test Set 100kv AC High Voltage Set AC Hipot Tester
- AC DC Hipot Test Set High Voltage Hipot Tester
- AC DC Hipot Test Kit HV Transformer High Voltage Tester System
- Automatic AC DC Hipot Tester High Voltage Withstand Test Set Oil Immersed High Potential Tester
- Automatic DC AC Hipot Tester High Voltage Withstand Test Set High Pot Test Set
- AC DC Hipot Tester for Transformer High Voltage Cable Price
- 250kV High Voltage Series AC Resonant Test System for GIS-SXBP
- AC Series Resonant Test System for Substation Equipment-SXBP
- AC Resonant Test System (for Generators)/Voltage Withstand Test Device-SXBP
- 108KV Variable power Frequency Series AC Resonant test systems for high voltage cables-SXBP
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Testing Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-