Home > Products > Spectrophotometer > Full Spectrum Direct Read Spectrometer with high quality
Full Spectrum Direct Read Spectrometer with high quality
- 500 Piece / Pieces per Month
- Shanghai
- T/T Credit Card
-
Optical emission spectrometer Full Spectrum Direct Reading spectrophotometer price
-
Atomic Absorption Spectrophotometer price
-
hollow cathode lamp for AAS
-
DV-8000 Visible 721 spectrophotometer price
-
DV-8200/DU-8200 UV-VIS Spectrophotometer Price
-
DU-8600RN Split Beam cheap uv/vis spectrophotometer china oem
Product Details
Brand Name: | DRAWELL | Place of Origin: | Shanghai, China | Model Number: | DW-TY-9000 |
Size: | 725*865*550(mm) | Weight: | 80kg | Measurement Range: | 380nm~780nm |
Wavelength Range: | 130~800nm | Focal Length: | - |
Product Description
DW-TY-9000 Type Full Spectrum Direct Reading Spectrometer
General principles
The buyer is responsible for providing the conditions and requirements of the site, and meet the requirements of the external installation and other cooperation conditions, the Seller shall provide the equipment and technical services in accordance with the requirements of this agreement. The seller (to ensure full compliance) shall comply with the requirements of the technical specifications, and the analytical instrument shall meet the requirements of the national (or industry) standards.
DW-TY-9000 Full Spectrum Direct Reading Spectrometer, which adopts the international standards of design and manufacturing technology, follows the steps of international spectrum technology and applied the new all digital technology instead of PMT simulation technology. In addition, in order to make this apparatus' best capability, long term stability and repeability, and the lowest sense lines. The design of vacuum optics room and the technology of all digital excitation light source, advanced CCD detector, high-speed data reading system are applied. This machine is available in metal manufacture and processing industries. It's also one of the main testing machine in metal metallurgy. Such as quality monitoring, material grade identification, material research and development.
Specifications and technical parameters
Item | Index |
Detection of substrate | Fe,Al,Cu,Ni,Ti,Co,Zn,Sn,Mg,Pb etc |
Testing time | According to the sample type, generally about 25s |
Optical system | The Paschen Runge construction full vaccum type optics system |
Wavelength coverage | 130~800nm |
Focal length | 400mm |
Detector | High-performance CCD Array |
Electrode | Tungsten material injection electrode |
Analytical gap | The sample analysis of clearance: 3.4mm |
Operating temperature | (10~35)℃ |
Storage temperature | (0~45)℃ |
Operating humidity | 20%~80% |
Argon purity requirements | 99.999% |
Argon gas inlet pressure | 0.5MPa |
Argon flow | Stimulate the flow around 3.5L/min,Maintain flow around 0.4L/min |
Stimulate the maximum power | 400VA |
Type of Lamp-house | New digital adjustable light, high energy precombustion technology(HEPS) |
Discharge frequency | 100-1000 Hz |
Discharge current | Maximum 400A |
Excitation aperture | 13mm |
Vacuum system | The vacuum automatic control and monitoring software |
Working power supply | 220V AC, 50/60Hz, single phase power supply for protective grounding |
Instrument size | 725*865*550(mm) |
Instrument weight | 80kg |
Notes:
(1) The table filled in accordance with contract demand of customers;
(2) If the customer has control sample needs to provide control sample number, by the customer to buy their own; for example, sales staff and buy, the control sample Shanghai shipped separately;
(3) If the client application is a special application, and are willing to cooperate to provide samples for curve development, the customer must provide accurate sample elements in the table, and to ensure uniformity of the sample, but not as an instrument of this type of curve acceptance criteria;
Environmental Requirements
Instrument shall be placed in a dedicated laboratory, indoor area larger than 10 square meters, and to ensure that surrounding non hazardous, flammable and corrosive gases. Caution: Do not use this instrument placed in the chemical analysis laboratory.
Working temperature: 10℃ ~ 30℃, within 3 hours at room temperature fluctuation is less than 2℃, requires laboratory installation of air conditioning.
Storage temperature: 0℃ ~ 45℃
Relative Humidity: 20% to 80%, for wet areas, to be equipped with a dehumidification machine.
TY-9000 full spectrum of direct-reading spectrometer spectral chamber mounted in the housing having a temperature control device, can work in such an environment range, if beyond the scope of these requirements, service life and measurement accuracy of the instrument will be affected.
Power Requirements
1) Power supply: single-phase 220 ± 20V, 1KVA power supply.
In order to ensure TY-9000 full spectrum direct reading spectrometer normal use, please for the instrument is equipped with a 1kVA single-phase 220V AC voltage regulator parameters.
2) TY-9000 full spectrum of direct-reading spectrometer with protective grounding single-phase power. To ensure reliable instrument, the user must ensure the grid PE protected well grounded and separate from other protected areas of large equipment. If you can not guarantee that PE is well grounded, please prepare a ground instrument separately for grounding resistance of less than 4Ω.
Argon requirements
1) Argon purity≥99.999%, oxygen≤2ppm, including the amount of H2O≤5ppm, (argon gas cylinders can not open storage, non-rain). If there is no purity argon gas, argon gas purifier is recommended.
2) The use of argon gas flow rate: standby flow rate of about 0.1L/min, maintaining the flow of about (0.4-0.5) L/min, to stimulate the flow of about 3.5L/min.
3) Argon pressure control: 0.5Mpa.
Argon connection pipe
You must use special argon supplied brass connection.
Row of cylinders
Instrument exhaust gas through a 14mm diameter PVC reinforced pipe routed supplied filter bottle. Exhaust bottle should be cleaned in time to prevent poor gas replacement.
Sample Preparation
Non-ferrous metal samples for aluminum, copper, etc. must use special lathe sample preparation.
For iron-based samples must use special sample preparation grinding prototype, a prototype mill and a floor-grinding machine for grinding steel sample surface. White cast iron samples must be uniform.
Users need a cutting machine for processing shape suitable for spectrometric analysis of samples.
Samples to be analyzed must be uniform, no holes, no casting defects, preparation must achieve a smooth surface, no oxide layer, no oil, no burr edge of the sample.
Standard sample request
TY-9000 full spectrum of direct-reading spectrometer factory will be bundled with a spectral calibration standards for the overall spectral calibration instrument drift. In addition, users need to prepare for their own internal control standard sample or sample product type, for correcting the instrumental analysis curve.
PC and printer requirements
Prepare a general configuration of the current PC (notebooks and desktops can be), requires more than 1GB memory, CPU dual-core 1.8G Hz or more, for the installation TY-9000 full spectrum of direct-reading spectrometer analysis software.
Prepare a printer, laser, inkjet or dot matrix printer can be used to analyze the data to print the report.
Installation and commissioning
Instruments arrive within a month, the buyer should have the installation conditions and notify the seller installed.
After installation engineers arrived, along with the packing list one by one to check received by both parties, representatives of both parties to fill the packing list in duplicate entries in acceptance based on test results and signed. If missing parts on the acceptance of a single note by the installation engineer and immediately notify the seller sent it to us.
Instruments arrive within two months the buyer still have installation conditions, or cause damage to the instrument in custody, the seller is entitled to require the buyer to pay the additional installation costs, all costs for equipment damage caused by the formation of custody shall be borne by the buyer.
In instrument installation and commissioning, the buyer should be given to facilitate the installation engineer working conditions. Because if the buyer does not have the installation conditions resulting installation engineers to the scene after the unable to work and staying two days (or more), installation engineers can directly return, and to assume the installation engineer during detention by the buyer of the full cost, including transportation to and installation engineers fees, room and board, fees and subsidies.
If the content is not individual elements within a selected range of standard content, or after installation of its RSD, SD value exceeds the allowable value, the two sides should negotiate, analyze problems and propose solutions to problems.
After acceptance, representatives of both parties sign it in duplicate on the acceptance of a single installation.
Note: For customers with samples to create a curve as a standard case, because the customer can not guarantee uniformity of standards, samples of impurities can not be completely sure, the sample providers do not have the qualifications national standard production, so the results of the analysis can not be used as acceptance criteria .
Installation steps:
1) Engineer to the site according to the instrument installation procedures for installation, commissioning.
2) Test sample selection:
According to the buyer's analysis of the content of the sample, the seller and the buyer to jointly negotiate to determine, select a set of suitable for the user's daily analysis of the standard sample (the set of the buyer to provide or negotiate with the seller purchasing), as the instrument of acceptance. The standard sample selection principle should be based on the principle of the content of the daily production of the buyer.
3) Test:
After the instrument, the instrument temperature, pressure and argon atmosphere after the instrument to meet the requirements of the instrument, by the seller and the installation engineer with a set of pre - determined, the establishment of the instrument, and then the two sides agreed to take a sample of the standard sample (usually not containing high and low standard sample) for precision testing. General provision of 4~6 points (excluding abnormal excitation) of data to calculate.
After acceptance, the installation of the negotiators in duplicate sign acceptance certificate.
Contact Us
- Shanghai Drawell Scientific Instrument Co., Ltd.
-
DU-8800D/DU-8800DS Portable Price Of SpectrophotometerTypes
-
DW-K2800 Nucleic Acid Analyzer Microplate Nanodrop Spectrophotometer
-
Drawell DW-XRD-27mini portable mini xrd benchtop spectrophotometer
-
Fourier Transform Infrared Spectroscopy Analyzer Price FTIR
-
DW-FTIR-530 Fourier Transform Infrared Spectroscopy FTIR
-
FP640 Laboratory Flame Photometer K Na Li Price
-
Drawell F96PRO Portable Fluorescence Spectrophotometer Price
-
DW-S430 NIR Spectrophotometer Portable NIR Spectrometer
-
Hand-held Alloy Analyzer(Truex 860) handheld spectrometer price
-
Handheld Mineral Analyzer (TrueX 960) portable heavy metal analyzer
-
Handheld XRF ROHS Analyzer (TrueX 600)
-
Handheld XRF Gold Analyzer(TrueX GOLD) with high performance
-
TY-9900 Inductively Coupled Plasma Atomic Emission Spectrometer
-
atomic absorption spectrometer price aas spectrophotometer in china
-
Manufacturer data color spectrophotometer for sale
-
DU-8600R UV/VIS uv Spectrophotometer model nanodrop spectrophotometer price
-
DU-8800D/DU-8800DS double beam uv-vis spectrophotometer cheap spectrophotometer
-
DW-K2800 Nano-Spectrophotometer Nucleic Acid Analyzer for lab
-
Handheld Alloy Analyzer XRF spectrometer
-
Handheld XRF Analyzer TrueX 860 Portable XRF
-
Handheld Mineral Analyzer XRF Elemental Analysis(TrueX 900)
-
Handheld XRF Mineral Analyzer Price(TrueX 960)
-
XRF Handheld Analyzer Handheld XRF ROHS Analyzer (TrueX 600)
-
Handheld XRF Gold Analyzer XRF Gold Testing Machine Price(TrueX GOLD)
Popular Searches
- spectrophotometer
- infrared spectrometer
- spectrometer
- vis spectrophotometer
- photometer
- visible spectrophotometer
- lumen tester
- Fluorescence Spectrophotometer
- Double Beam Spectrophotometer
- Uv Spectrophotometer
- Single Beam Spectrophotometer
- Scanning Spectrophotometer
- Portable Spectrophotometer
- Grating Spectrophotometer
- Aas Spectrophotometer
- Spectrometers
Find Similar Products By Category
- Measurement & Analysis Instruments > Optical Instruments > Spectrometers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-