Home > Products > EV Charging Meter > Acrel ARCM200L-Z residual current electrical fire monitoring detector RS485 modbus leakage current power meter
Acrel ARCM200L-Z residual current electrical fire monitoring detector RS485 modbus leakage current power meter
- 1000 Set / Sets per Month
- T/T Credit Card
- Acrel ARCM200L-Z2 residual current electrical fire monitoring detector 2 channel RS485 modbus leakage current power meter
- Acrel ARCM200BL-J4 residual current electrical fire monitoring detector 4 channel leakage current meter
- Acrel ARCM200BL-J1residual current electrical fire monitoring detector leakage current meter
- Acrel ARD2L-250 timeout startup, over load, unbalance, blocking, short circuit 55KW 75KW 90KW 110KW 132KW motor protector
- Acrel ARD2L-1 timeout startup, over load ,phase failure, unbalance, earth leakage, blocking, short circuit motor protector
- Acrel ARD2-800 timeout startup, over load, unbalance, blocking, short circuit 160KW 200KW 220KW 250KW motor protector
Product Details
Brand Name: | Acrel | Place of Origin: | Jiangsu, China | Model Number: | ARCM |
Product Description
ARCM200L series multi-circuit type electrical fire monitoring detector (hereinafter referred to as the detector), is designed for 0.4 kV below TT, TN system design, through the monitoring and management of distribution of residual current circuit, the conductor temperature, over current, over voltage fire danger parameters, to prevent the happening of the electrical fire, and realizes the real-time monitoring of various power parameters, and provide data for energy consumption management.
The product adopts advanced microcontroller technology, is of high integration, small size, easy installation. It integrates it with intelligentization, digitalization, network, is an ideal choice for building electrical fire prevention monitoring, insulation aging prediction of the system.
The products meet the standard requirements of GB14287.2-2014 electrical fire monitoring system part 2: residual current electrical fire monitoring detector and GB4287.3-2014 electrical fire monitoring system part 3: temperature measuring electrical fire monitoring detector.
2 Product model
Sheet 1
ARCM200L | ||
|
| Three phase TT,TNS,TN-C-S or TNC(part of TT)system |
Frequency | 50Hz | |
Residual current measure range | 10mA ~ 3000mA | |
Output | Communication | RS485 interface, MODBUS-RTU protocol |
Alarm method | Sound-light alarm | |
SOE | 20 alarm records,20 malfunction records,20 switching records | |
Alarm set | Rated operation current value | 300mA~1000mA(step size is 1mA)
|
Sound pressure of audio device | >70dB,<115dB(1m in front of the buzzer, A count) | |
| Residual current class1 | |
Working power supply | AC/DC 85~270V, energy consumption≤ 5VA | |
Switching input | 4-channel passive dry contact input (optocoupler isolation) | |
Relay output | Output method:2-channel relay normally open contact output, mechanical contact,contact capacity AC 220V/3A,DC 30V/3A | |
Power frequency withstand voltage | Among power supply with signal input,relay output and communication terminal, is 2 kV/min; Among signal input with relay output and communication terminal, is 1.5 kV/min | |
Environment | Working temp:-10℃~+45℃;storage temp:-20℃~+70℃ Relative humidity:5%~95% without condensation;Altitude:≤2500m |
Outline and dimension of ARCM200L shown in figure1:(unit:mm)
4.2 Installation method
Installation mode of ARCM200L type is embedded and the fixed mode is extruded, shown in figure 2.
Figure 2
4.3 Wiring instructions(wiring is subject to the wiring diagram on the detector )
4.3.1 Wiring method
Upper terminal: "12, 13" is the auxiliary power supply;"34, 35, 36" is relay output (DO1 is alarm output, DO2 is trip output);"24, 25, 26, 27, 28" is the on-off input;"21" and "22" are communications
J16 type wiring terminal:
Middle terminal: "53 ~ 64" is leakage current signal input (COM7, COM8, COM9, COM10 are not grounded)
4.4 Matters need attention
4.4.1 Connection method of residual current transformer
Sheet 2
ATTN: as shown in the above table, when installing the residual current transformer, the N line and PE line must be strictly distinguished. In the three-phase four-wire system, the N line must run through the residual current transformer.The N wire passing through the residual current transformer shall not be used as PE wire, and shall not be repeatedly grounded or exposed to the conductor.PE wire shall not be used for residual current transformer.In TN-C system, the system must be modified to form local TT system, or transformed into TN-C-S system, and then connected according to the above table.
4.4.2 Auxiliary power supply connection
In combination with the above figure, when connecting the auxiliary power supply, the wire shall be made in the way as shown in figure 3. When making the wire, first press the wire head tightly, and then fix it with tin;The wiring is shown in figure 4. Insert it into the terminal row and tighten it with a screwdriver,to ensure the normal operation of the power supply.
4.4.3 Communication wiring
The device provides asynchronous half duplex RS485 communication interface, using modbus-rtu protocol, all kinds of data information can be transmitted on the communication line.Theoretically, up to 32 devices can be connected simultaneously on a single line, and each device can set its address and communication rate.It is recommended to use two core shielded wires with A diameter of no less than 0.75mm2, connected to A and B respectively. The shielding layer is connected to the ground or suspended at A single point. When wiring, the communication lines should be kept away from strong electric cables or other strong electromagnetic environment.
4.4.4 Sensor matching and installation
There are two kinds of external sensors, residual current transformer and temperature sensor, which are customized products and cannot be used to replace products of other manufacturers at will.When wiring, the secondary signal of residual current transformer does not distinguish the direction of current.
Company Profile
Acrel Co., Ltd.[stock code: 300286.sz] is a high-tech enterprise integrates R&D, production, sales and service, since its establishment, it committed to provide users with energy efficiency management and power security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors. At present, more than 8,000 sets of various solutions are running all over the country, help users to realize the visual management of energy consumption, provide users the energy data services, and escort users an efficient and safe energy consumption.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
Contact Us
- Jiangsu Acrel Electrical Manufacturing CO.,LTD
- Contact nameTim
- Phone86-1870-6168051
- AddressJiangyin Wuxi,Jiangsu
- Acrel ARD2-250 timeout startup, over load, unbalance, blocking, short circuit 55KW 75KW 90KW 110KW 132KW motor protector
- Acrel ARD2-25 timeout startup, over load, unbalance, blocking, short circuit 3KW 5.5KW 7.5KW 11KW motor protector
- Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW motor protector
- Acrel PZ96-AI3/JC ac three phase led programmable digital current panel meter optional over under curret alarm rs485 modbus
- Acrel PZ96-AI3/K ac three phase led programmable digital current panel meter with 4 di/2do
- Acrel PZ96-AI3/M ac three phase led programmable digital current panel meter with one analog output
- Acrel PZ96-AI3/MC ac three phase led programmable digital ammeter optional one analog output rs485 modbus
- Acrel PZ96-AI3/JC ac three phase led programmable digital ampere meter optional over under curret alarm rs485 modbus
- Acrel PZ96-AI3/J ac three phase led programmable digital ampere meter with over under current alarm
- Acrel PZ96-AI3/K ac three phase led programmable digital ampere meter with 4 di/2do
- Acrel PZ96-E4/KC three phase led programmable digital power meter optional 4DI 2DO
- Acrel PZ96-E3/MC led programmable digital panel meter optional RS485 4-20mA output over current alarm
- Acrel PZ72L-AI/MC lCd programmable digital single phase ammter ampere meter optional RS485 analog output
- Acrel PZ72L-AI/C single phase lcd programmable current meter solar power meter optional RS485 modbus
- Acrel PZ72-AI3 ac three phase programmable led digital ammeter current meter
- ACREL PZ96L-E4 3P4W AC Multi-function smart energy analyzer electric meter with LCD display
- Acrel 300286 PZ96L-E4/KC AC LCD three phase smart power analyzer electric meter with rs485 4 digital input 2 digital output
- AC PZ96L-E4/KC LCD display three phase energy meter panel meter with rs485 2DI/2DO
- PZ96L-E4/MC AC LCD three phase power meter panel meter with rs485 4-20mA analog output
- PZ96L-E4/KC Multi-function remote control meter with switching and communication functions
- PZ96L-E4/C AC LCD three phase voltage current power kwh meter panel meter with rs485
- Acrel PZ72-AI/JMC single phase led programmable digital panel meter ampere meter optional RS485 4-20mA output alarm
- Acrel-5000 power meter Energy Management System
- Acrel5000 Energy consumption Management System
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Tim
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-