Acrel AMC16-DE6 DC48V Telecom Site DC Power Meter

Acrel AMC16-DE6 DC48V Telecom Site DC Power Meter photo-1
Acrel AMC16-DE6 DC48V Telecom Site DC Power Meter photo-2
Acrel AMC16-DE6 DC48V Telecom Site DC Power Meter photo-3
Acrel AMC16-DE6 DC48V Telecom Site DC Power Meter photo-4
US$ 63 - 63 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
ACREL
Place of Origin:
Jiangsu, China
Model Number:
AMC16-DE6
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Brand Name ACREL
Place of Origin Jiangsu, China
Model Number AMC16-DE6
Operating Temperature -25~60
Dimensions 72*87
Measuring Voltage Range 0~1000V
Measuring Current Range 0-9999A
Accuracy Class 1
Product Description

AMC16-DE6 Is an economical and practical multi-channel DC current measuring device. Which collect, monitoring and control the DC current.

Electrical parameter measuring

6 channels voltage, current, active power, active energy.

Switch State

6 channels DI, 1 channel DO

 

voltage

measuring range

DC35~60V

overload

 instant 2 times/30s

current

hall sensor

 voltage input: 0-5V

measuring range

0-2000A

overload

Continue 1.2time, instant 10 times/5s

auxiliary power

DC48V±20%

accuracy

current voltage

0.5

power, energy

1.0

consumption

<5VA

relay output

5A 250VAC/5A 30VDC

 environment

working temperature

-10℃~55℃

 storage temperature

-20℃~70℃

relative humidity

≤93%

altitude

≤2500m

communication

RS485


p
arameter checking

Press“←” to inquire as per group

the group is distinguished as per the items

V-voltage, A-current, Kw-active power, Kwh-active energy, switch-“-”open,“r”close

Press“→” to inquire as per phase

L1,L2,L3,L4,L5,L6 represents channel 1-6;

Current, power shows the primary value, energy shows the primary value, and shows the high and low level. When A, Kw, Kwh indicators are all on, means energy is in high level. V, A, Kwh represents energy low level.

i.e. inquires 1 channel energy H1234kWh,L 56.78kWh,this value means 123456.78kWh;

When the energy is larger than 999999.99kwh, it reserve one decimal.

 

parameter setting

press“PROG”->pass->press“Enter”->insert pass word->IE(primary current/1 channel->6 channel)->addr(address setting)->baud(baud setting)->codE(password setting)->clr.E(Power reset)->zEro(zero calibration)->“PROG”withdraw ->savE(press“Enter”save the setting/press“PROG”cancel the setting)

 

 Press “←/→” to modify the value,“→”to change the menu.

 In zEro item, press”←”and Enter can process the zero calibration,select yEs or no.

 

terminals

1,2

auxiliary power

4-9

current 1-6, hall effect sensor signal input

11-16

voltage negative

10

voltage positive

30,31

RS485

50,51

DO output

+12V

+12V voltage output

-12V

-12V voltage output

GND

voltage type hall sensor output negative insert.

wiring
 
Hall sensor powered by the build-in

 Hall sensor powered by external power

installation

notice

The device should be installed in a dry, clean place away from heat source and strong electromagnetic field

When the hall sensor goes through the heart, pay attention to the current direction, otherwise the measurement will be inaccurate

The current input must use hall sensor, and the current value of each circuit can be set separately

If it is not necessary to detect the switching state, only 1-channel voltage signal can be connected to terminal 10 and 11, that is, the 1-channel voltage

Communication cables shall be shielded twisted pair

Note whether the hall sensor is matched with the required input signal of the device (the hall sensor output is required to be 0-5v).

If the device is used to power multiple hall sensors, the phenomenon of on-load and on-off may occur. At this time, an external power supply should be used to power the hall sensor, and GND terminal on the device should be connected to the external power supply

Packaging & Shipping

 Acrel AMC16-DE6  DC48V Telecom site DC power meter

Our Services

 Acrel AMC16-DE6  DC48V Telecom site DC power meter

 

Company Information

 Acrel AMC16-DE6  DC48V Telecom site DC power meter

FAQ

 

Analysis of common faults and causes

The measurement of the device is not accurate

Check whether the positive and negative terminals of the voltage are correct

Is the current passing through the hall sensor in the right direction

Check whether the IE setting of the device is consistent with the hall sensor used

Whether the output signal of hall sensor matches the required input signal of the device;

Check whether the output negative pole of the voltage output hall sensor is connected to the device GND 

Abnormal communication

Check whether the communication cable is connected normally

Check whether the A and B terminals of communication are staggered

Check whether the device address is set correctly and the communication baud rate is set correctly

Multi - device communication is not normal, first try the single communication, to see if it is normal.

The device does not display properly

Check whether it is caused by the insufficient carrying capacity of the built-in power supply to the hall sensor. Replace the external switching power supply to power hall

 

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2006
Annual Export Value
US$1.5 Million - US$2.5 Million
Product Certifications
ISO9001

Recommended Categories

Explore top categories and find suppliers for your specific needs
Jiangsu Acrel Electrical Manufacturing CO.,LTD AIBot OnlineThis conversation is AI-generated. Contact manufacturer before transaction to confirm info.
  • Tim
    Hi there! Welcome to my shop. Let me know if you have any questions.

Please enter a correct verification code.

Tim Overseas sales engin
Hi there! Welcome to my shop. Let me know if you have any questions.