Home > Products > energy meter > Acrel AGF-M4T day meter for combiner box in solar energy system
Acrel AGF-M4T day meter for combiner box in solar energy system
Negotiable
/ Piece
1 Piece(Min.Order)
- 99999 Piece / Pieces per Month
- T/T
You May Like
- Acrel ADF400L-3D 3 circuits single phase 10(80)A High accuracy
- Acrel ADF400L-4H Multi Circuit Electrical Instruments 4 channel 3 phase 3*1(6)A High installation flexibility
- Acrel Multi Circuit Electrical Instruments 2 channel 3 phase 3*10(80)A ADF400L-2S din rail
- Acrel din rail Multi Circuit Electrical Instruments 6 channel single phase 10(80)A High installation flexibility ADF400L-6D
- Acrel 6 channel three phase 3*1(6)A High installation flexibility din rail ADF400L-6H Multi Circuit Electrical Instruments
- Acrel ADL3000-E Electrical Measuring Instrument 3 Phase Digital Energy Meter support 2-31st
Product Description
AGF-T Perforation type PV confluence acquisition device
1 General
AGF-T Perforation type PV confluence acquisition device is specially designed for smart PV combiner box. It is used for monitoring the running state of solar panels in solar cell arrays, measuring the currents of solar cell, detecting the state of surge protection devices and DC breaker. The device is equipped with RS485(Modbus) communication port for transmitting all the datas to master device.
2 Product Naming
*Power supply filter module is only optional when there is filtering requirements to power supply
3 Characteristics
Primary current is connected in through perforation. Easy installation, high safety
With Hall sensor, the max isolation measuring current 20A
Voltage measurement range for Bus bar is up to DC1kV
LED display, fit for checking and testing operation in wide-temperature or outside environment.
With the function of inner temperature measurement for real-time measurement of the inner temperature of combiner box
With RS485 Modbus RTU
More options of power supply
Compatible with din rail installation and baseboard fixation installation, small dimension saving more box space.
DC Bus bar voltage input circuit with built-in DC 1kV fuse
4 Product function
Photovoltaic cell open circuit alarm to cooperate with group string voltage and judge Comprehensively
With 3-channel switching state monitoring to collect output idle contact information of DC breaker ,lightning protector. protector etc
Option RS485 port, Modbus-RTU protocol; programmable slave address, baud rate, data format
English LCD display,convenient to set parameters and check the data
5 Technical Parameters
6 Outline and installation
6.1 Outline dimension
6.1.1 Power supply module and power supply filtering module size(Figure 1)
Note: Imaginary line is the fixing size of the bottom plate
As power supply module is heavy, bottom plate is needed in installation to avoid its coming off during transportation.
6.1.2 The extension module mounting dimensions (Figure 2)
Note: Imaginary line is the fixing size for base plate.
6.1.3 Confluence acquisition module installation dimension
8-channel confluence acquisition module installation dimension(Figure 3)
4-channel confluence acquisition module installation dimension(Figure 4)
Configuration of 8-channel or 4-channel confluence acquisition module will be decided by actual needs: when 4 channels or less are needed, 4-channel confluence acquisition module will be installed, when needed channel number is 5 to 8, 8-channel confluence acquisition module will be installed. When needed channel number is more than 8, then the number will be divided by 8. If there is a remainder in the result and the remainder is less than 4, then 4-channel confluence acquisition module will be installed. If the remainder is more than 4, 8-channel confluence acquisition module will be installed.
6.1.4 LCD display module installation dimension (Figure 5)
6.2 Connections of modules
6.2.1 Data cable connection way
The connection between each module is through the external data line. Please confirm the sequence of the two external data line ports before connecting each module. Each confluence acquisition module has two outside connection ports(Figure 4): Port I and Port II, in which Port I is used to connect upstream module and Port II is used to connect follow-up modules. Please pay attention to it that the propulsion part of the data line connector must be fixed with the groove on the port.
The connection sequence order of PV confluence acquisition modules must follow: confluence acquisition module 1's port Ⅱ-->confluence acquisition module 2's port , Ⅰ confluence acquisition module 2's port Ⅱ-->confluence acquisition module 3's port .When connecting the confluence acquisition modules ,multiple confluence modules should be in sequence order, it is not allowed to insert any other function module between two sequenced confluence modules. Wrong connection will lead to abnormal operation of the device.
LCD display module can be connected with Port II of confluence acquisition module, The LCD display module is not necessary to be connected in at ordinary time except when testing and checking.
The address allocation of PV confluence acquisition module is automatically distributed by the power module(main module), The first confluence acquisition module connected to the power module will be distributed automatically with 1st to 8th channels, and the next confluence acquisition module connected to port II will be distributed automatically with 9th to 16th channels, the final confluence acquisition module is distributed automatically with 17th to 24th channel.
6.2.2 Installation schematic
Note: The arrow shows current direction. Wrong connection will lead to abnormal operation of the device.
6.3 Definition of input port
After the address of confluence acquisition module is distributed by the main module,the input channel address of first module is from 1st to 8th channel,the input channel address of second confluence acquisition module is from 9th to 16th channel,the input channel address of final confluence acquisition module is from 17th to 24th channel. The input channel definition of 1st to 8th channel of a single module is shown as Figure 3.
7 Wiring mode
Note: Power supply circuit and voltage measuring circuit must be installed with fuse with 3A rated current and rated voltage that is the highest working voltage in these circuits to ensure safety.
Contact Us
- Jiangsu Acrel Electrical Manufacturing Co.,LTD.
- Contact nameRobin Wong
- Phone86-188-60990280
Product Categories
New Products
- Acrel ADL3000-E/C 7P three phase multi-function energy meter supporting infrared communication 3 split transformers included
- Acrel three phase smart energy meter LED display 2DI2DO cut out 67*67mm AMC72-E4/KC Accuracy level 0.5
- Acrel Intelligent power collection and monitoring device AMC72L-E4/KC three phase LCD display 2DI2DO panel size 75*75mm
- Acrel with LCD display NB communication Multi-loop intelligent power collection and monitoring device 6 switching inputs
- Acrel 4G communication DC multi-circuit intelligent power collection and monitoring device is applied to tower base stations
- Acrel connect to12 single-phase DC circuits at the same timewith LCD display, Full electrical parameter measurement AMC200L-12DE
- Acrel AC multi-loop intelligent power acquisition and monitoring device With LCD display, 1 channel RS485 AMC200L-4E3
- Acrel for hospital operating room AID150 medical digital centralized alarm insulation display instrument indicator device
- Acrel insulation monitoring device multiple fault indication function Mainly used in IT power distribution systems AIM-T300
- Acrel Din Rail Energy Meter ACR10R-D36TE Solar Din Rail Energy Meter Single Phase LCD RS485 Modbus RTU DIN 35mm AC 85-265V/ DC 100-350
- Acrel ACR10R-D24TE single phase intelligent solar inverter energy meter power monitor with RS485 connection
- Acrel PV/Solar inverter energy meter LCD display RS485 communication single phase ACR10R-D16TE
- Acrel ACR10R-D10TE LCD display for PV/Solar din rail RS485 single phase multifunction power meter
- Acrel inner diameter of transformer16mmADW310-HJ-D16/C single phase wireless energy meter RS485communication
- Acrel ADW310-HJ-D10/WF WF communication single phase IOT smart energy meter din rail type Read data remotely
- Acrel ADW310-HJ-D10/C single phase RS485communication inner diameter of transformer 10mm
- Acrel ACR220ELH three phase Embedded network power meter LCD display Intelligent and digital, it is widely used in various control systems.
- Acrel Multi Circuit Electrical Instruments din rail 9 channel single phase 10(80)A High installation flexibility ADF400L-9D
- Acrel Multi Circuit ADF400L-10H din rail Electrical Instruments 10 channel three phase 3*1(6)A High installation flexibility
- Acrel three phase Electrical Instruments ADF400L-12H din rail Multi Circuit 12 channel 3*1(6)A High installation flexibility
- Acrel three phase ADF400L-6S Multi Circuit Electrical Instruments 6 channel 3*10(80)A High installation flexibility
- Acrel Multi Circuit Electrical Instruments 6 channel three phase 3*10(80)A High installation flexibility din rail ADF400L-6S
- Acrel ADF400L-2H din rail 2 channel Multi Circuit Electrical Instruments three phase 3*1(5)A High installation flexibility
- Acrel 1 channel three phase 3*10(80)A High installation flexibility ADF400L-1S din rail Electrical Instruments Multi Circuit
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Robin Wong
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Contact supplier for lowest price
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-