Home > Products > Oil Immersed Transformer > distribution transformer
distribution transformer
- 1000000 Kilovolt / Kilovolts per Month
- Tianjin,Shangshai,Ningno
- T/T L/C
Product Details
Brand Name: | ZYDQ | Place of Origin: | China |
Product Description
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
Product Description
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.
Product Features
● Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series.
● Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air, so that extend the service life effectively.
● High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
● Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
Model and Meaning
Table 1: 6Kv, 10kV & 30kVA-2500kVA Power Transformer With Off Circuit Tap Changer
Rated Capacity (kVA) | Voltage Combination | Connection Group Symbol | No-load Loss R(W) | Load Loss R(W)75℃ | Impedance Voltage (%) | No-load Current(%) | Length L(mm) | Width W (mm) | Height H(mm) | Gauge Horizontal*Vertical(mm) | Active parts Weight(Kg) | Oil Weight(Kg) | Total Weight(Kg) | ||
(KV) High Voltage | Tapping Range of High Voltage | (KV)Low Voltage | |||||||||||||
30 | 66.31010.5 | ±5%±2×2.5% | 0.4 | Dyn11Yzn11Yyn0 | 100 | 630/600 | 4.0 | 2.8 | 980 | 735 | 1145 | 400*400 | 178 | 78 | 355 |
50 | 130 | 910/870 | 2.5 | 1017 | 758 | 1205 | 450*400 | 240 | 92 | 415 | |||||
63 | 150 | 1090/1040 | 2.4 | 1035 | 785 | 1285 | 450*400 | 285 | 105 | 505 | |||||
80 | 180 | 1310/1250 | 2.2 | 1065 | 800 | 1290 | 450*400 | 330 | 110 | 540 | |||||
100 | 200 | 1580/1500 | 2.1 | 1072 | 820 | 1305 | 450*400 | 345 | 116 | 590 | |||||
125 | 240 | 1890/1800 | 2.0 | 1155 | 1105 | 1310 | 450*550 | 415 | 135 | 705 | |||||
160 | 280 | 2310/2200 | 1.9 | 1235 | 850 | 1535 | 550*550 | 485 | 155 | 835 | |||||
200 | 340 | 2730/2600 | 1.8 | 1282 | 860 | 1557 | 550*550 | 582 | 168 | 965 | |||||
250 | 400 | 3200/3050 | 1.7 | 1310 | 940 | 1605 | 550*550 | 695 | 210 | 1135 | |||||
315 | 480 | 3830/3650 | 1.6 | 1465 | 1120 | 1915 | 660*650 | 855 | 255 | 1520 | |||||
400 | 570 | 4520/4300 | 1.5 | 1440 | 1165 | 1725 | 660*660 | 950 | 295 | 1590 | |||||
500 | 680 | 5410/5150 | 1.4 | 1510 | 1250 | 1845 | 660*650 | 1150 | 320 | 1905 | |||||
630 | 810 | 6200 | 1.3 | 1650 | 1140 | 1920 | 660*650 | 1500 | 435 | 2015 | |||||
800 | 980 | 7500 | 4.5 | 1.2 | 2125 | 1175 | 2315 | 820*820 | 1910 | 760 | 3510 | ||||
1000 | 1150 | 10300 | 1.1 | 2150 | 1380 | 2570 | 820*820 | 2125 | 880 | 3850 | |||||
1250 | 1360 | 12000 | 1.0 | 2355 | 1485 | 2570 | 820*820 | 2605 | 960 | 4610 | |||||
1600 | 1640 | 14500 | 0.9 | 2385 | 1750 | 2630 | 820*820 | 3125 | 1150 | 5420 | |||||
2000 | 1940 | 18300 | 5.0 | 0.4 | 1940 | 1400 | 1700 | 820*820 | 2420 | 780 | 4200 | ||||
2500 | 2290 | 21200 | 0.4 | 2050 | 1480 | 1800 | 820*820 | 2560 | 880 | 4680 |
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
Technical Parameter for S11 Series 20kV Power Transformer With Off Circuit Tap Changer
Rated capacity(KVA) | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W)75℃ | No-load Current (%) | Short-circuit Impedance(%) | ||
High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | ||||||
30 | 20 | ±5% ±2×2.5% | 0.4 | Dyn11Yzn11Yyn0 | 100 | 690/660 | 2.1 | 5.5 |
50 | 130 | 1010/960 | 2.0 | |||||
63 | 150 | 1200/1150 | 1.9 | |||||
80 | 180 | 1440/1370 | 1.8 | |||||
100 | 200 | 1730/1650 | 1.6 | |||||
125 | 240 | 2080/1980 | 1.5 | |||||
160 | 290 | 2540/2420 | 1.4 | |||||
200 | 340 | 3000/2860 | 1.3 | |||||
250 | 400 | 3520/3350 | 1.2 | |||||
315 | 480 | 4210/4010 | 1.1 | |||||
400 | 570 | 4970/4730 | 1.0 | |||||
500 | 680 | 5940/5660 | 1.0 | |||||
630 | 810 | 6820 | 0.9 | 6.0 | ||||
800 | 980 | 8250 | 0.8 | |||||
1000 | 1150 | 11330 | 0.7 | |||||
1250 | 1380 | 13200 | 0.7 | |||||
1600 | 1660 | 15950 | 0.6 | |||||
2000 | 1950 | 19140 | 0.6 | |||||
2500 | 2340 | 22220 | 0.5 |
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
3. The performance parameters in the table are also applicable for HV with dual voltage 20 (10)kV three-phase transformer.
Technical Parameter for S11 Series 35kV Power Transformer With Off Circuit Tap Changer
Model | Voltage Combination | Connection Group Symbol | No-load Loss (W)75℃ | Load Loss R(W) | Impedance Voltage (%) | No-load Current(%) | Length L(mm) | Width W(mm) | Height H(mm) | Gauge Horizontal*Vertical (mm) | Active parts Weight(Kg) | Oil Weight(Kg) | Total Weight(Kg) | ||
High Voltage (kV) | Tapping Range of High Voltage % | Low Voltage (kV) | |||||||||||||
50 | 3538.5 | ±2×2.5%±5% | 0.4 | Dyn11/ Yyn0 | 160 | 1200/1140 | 6.5 | 1.3 | 1195 | 935 | 1825 | 660*660 | 300 | 330 | 860 |
100 | 230 | 2010/1910 | 1.1 | 1200 | 995 | 1935 | 660*660 | 470 | 383 | 1130 | |||||
125 | 270 | 2370/2260 | 1.1 | 1235 | 940 | 1955 | 660*660 | 550 | 465 | 1335 | |||||
160 | 280 | 2820/2680 | 1.0 | 1285 | 895 | 1950 | 660*660 | 580 | 485 | 1475 | |||||
200 | 340 | 3320/3160 | 1.0 | 1310 | 1150 | 1985 | 660*660 | 680 | 595 | 1755 | |||||
250 | 400 | 3950/3760 | 0.95 | 1450 | 1090 | 2010 | 660*660 | 860 | 650 | 2000 | |||||
315 | 480 | 4750/4530 | 0.95 | 1930 | 1065 | 2320 | 820*820 | 980 | 765 | 2290 | |||||
400 | 580 | 5740/5470 | 0.85 | 1850 | 1165 | 2015 | 820*820 | 1170 | 885 | 2725 | |||||
500 | 680 | 6910/6580 | 0.85 | 2045 | 1205 | 2415 | 820*820 | 1340 | 960 | 3090 | |||||
630 | 830 | 7860 | 0.65 | 2085 | 1240 | 2515 | 660*660 | 1550 | 895 | 3810 | |||||
800 | 980 | 9400 | 0.65 | 2305 | 1615 | 2685 | 820*820 | 1990 | 1030 | 4510 | |||||
1000 | 1150 | 11500 | 0.65 | 2545 | 1540 | 2590 | 1070*1070 | 2415 | 1475 | 5055 | |||||
1250 | 1400 | 13900 | 0.60 | 2495 | 2010 | 2675 | 820*820 | 2480 | 1405 | 5290 | |||||
1600 | 1690 | 16600 | 0.60 | 2680 | 2100 | 2770 | 820*820 | 2600 | 1490 | 5450 | |||||
2000 | 1990 | 19700 | 0.55 | 2790 | 2180 | 2860 | 820*820 | 2720 | 1590 | 5600 | |||||
2500 | 2360 | 23200 | 0.55 | 2900 | 2290 | 2980 | 1070*1070 | 2830 | 1720 | 5760 |
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500KVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
Note: 1.For the transformer of low voltage 10.5kV, the connection group symbol is applicable to Dyn11.
Note: 2.For the transformer of rated capacity 3150kVA or above, the -5% tapping position is for maximum current tap.
Note: 3.When the annual average load rate for the transformer is between 35% to 45%, the loss value in the table can obtain the highest operational efficiency.
We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Contact Us
- Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
- Contact nameJia Qiong
- Phone86-312-5926018
- AddressLianchi Baoding,Hebei
Oil Immersed Transformer | Dry Type Transformer | ZBW Type Prefabricated Substation | High and Low Voltage Switchgears |
news |
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrel measuring rated current 250-400A low voltage leakeage CT Residual current transformer AKH-0.66/L L-100
- Acrel Applied to residual current signal collection residual current transformer AKH-0.66/L L-200 rated current 800-1500A
- Acrel AKH-0.66/L L-80 rated current 100-250A Applied to residual current signal collection measurement current transformer
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrelrated current 800-1500A Applied to residual current signal collection residual current transformer AKH-0.66/L L-200
- Acrel AKH-0.66/L L-45 residual current transformer rated current 16-100A Applied to residual current signal collection
- Acrel smart AC current transformer BA20(II)-AI/V Can be widely used in industrial automation fields
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
- Acrel BA50L(II)-AI/V smart AC electrical current sensor Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V smart AC electrical current sensor
- Made in China Three phase dry type transformer SG-100VA for thermal power plant
- Flyback transformer
- Lan transformer
- НЕФТЯНОЕ МЕСТОРОЖДЕНИЕ SHENGDONG SHENGLI газогенератор мощностью 500 кВт T12V190
- shengdong shengli oil field 500KW natural gas generator T12V190ZL
- B6190 G6190 200KW diesel engine used in ship boat spare parts
- B12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BH12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- AL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600lw
- Acrel smart AC electrical current sensor BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/I AC current sensor in AC0-(0.1-1)A out 4-20mA/0-20mA Real-time monitoring of AC current in the power grid
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- voltage transformer
Find Similar Products By Category
- Electrical Equipment & Supplies > Transformers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jia Qiong
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-