3000rpm 110v IEC Standard 3 Phases Permanent-magnet Synchronous Brushless DC Motor
| Type | Output | Speed RPM | Rated Torque NM | Efficiency % | Frame Size | Mounting | |||
| KW | HP | B3 | B5 | B14 | |||||
| VOL-IEC63S200-2P | 0.2 | 1/4 | 3000 | 0.64 | 90 | 63S | √ | √ | √ |
| VOL-IEC63S200-4P | 0.2 | 1/4 | 1500 | 1.27 | 90 | 63S | √ | √ | √ |
| VOL-IEC71S187-6P | 0.187 | 1/4 | 1000 | 1.78 | 90 | 71S | √ | √ | √ |
| VOL-IEC71S375-2P | 0.375 | 1/2 | 3000 | 1.19 | 90 | 71S | √ | √ | √ |
| VOL-IEC71S375-4P | 0.375 | 1/2 | 1500 | 2.38 | 90 | 71S | √ | √ | √ |
| VOL-IEC80S375-6P | 0.375 | 1/2 | 1000 | 3.58 | 90 | 80S | √ | √ | √ |
VIEW MORE PLS CONTACT US >>>



Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.
Send Inquiry to This Supplier
You May Also Like
-
DC Gear MotorNegotiableMOQ: 1 Set
-
High Quality High Pressure Hydraulic MotorNegotiableMOQ: 1
-
for PS2 5000X GEARNegotiableMOQ: 10 Pieces
-
Motorcycle Start Motor for XF125GY , Motorcycle Parts , Motorcycle Starter MotorNegotiableMOQ: 1 Piece
-
Elco Fan Motor(82 Series)NegotiableMOQ: 1000 Pieces
-
Motor Windscreen(ATV Windscreen, Motorcycle Windshield)NegotiableMOQ: 1
-
GE WR 60*10185 DC Evaporator Fan MotorUS$ 5 - 10MOQ: 400 Pieces
-
Motor Manufacturing in ChinaUS$ 20 - 500MOQ: 10 Pieces
-
Single Use Thermometer Label for Small Electric Motors / 1 LevelUS$ 63 - 125MOQ: 30 Pieces
-
Pump Electric MotorUS$ 1 - 50MOQ: 100 Pieces
Recommended Categories
Explore top categories and find suppliers for your specific needs-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.