| Motor type | Output Power | Voltage | Load | Speed | Rated Torque | Efficiency | Noise | IP Class |
| KW | V | A | RPM | Nm | % | dB | ||
| VOL-BL3K5A72 | 3.5 | 72 | 51.71 | 1500 | 22.28 | 94 | 62 | IP 54 |
| VOL-BL3K5A110 | 3.5 | 110 ac | 19.54 | 1500 | 22.28 | 94 | 62 | IP 54 |
| VOL-BL3K5A220 | 3.5 | 220 ac | 9.77 | 1500 | 22.28 | 94 | 62 | IP 54 |
| VOL-BL3K5A380 | 3.5 | 380 ac | 5.66 | 1500 | 22.28 | 94 | 62 | IP 54 |
| VOL-BL3K5B72 | 3.5 | 72 | 51.71 | 3000 | 11.14 | 94 | 62 | IP 54 |
| VOL-BL3K5B110 | 3.5 | 110 ac | 19.54 | 3000 | 11.14 | 94 | 62 | IP 54 |
| VOL-BL3K5B220 | 3.5 | 220 ac | 9.77 | 3000 | 11.14 | 94 | 62 | IP 54 |
| VOL-BL3K5B380 | 3.5 | 380 ac | 5.66 | 3000 | 11.14 | 94 | 62 | IP 54 |

VIEW MORE PLS CONTACT US >>>



Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.
Send Inquiry to This Supplier
You May Also Like
-
DC Gear MotorNegotiableMOQ: 1 Set
-
High Quality High Pressure Hydraulic MotorNegotiableMOQ: 1
-
for PS2 5000X GEARNegotiableMOQ: 10 Pieces
-
Motorcycle Start Motor for XF125GY , Motorcycle Parts , Motorcycle Starter MotorNegotiableMOQ: 1 Piece
-
Elco Fan Motor(82 Series)NegotiableMOQ: 1000 Pieces
-
Motor Windscreen(ATV Windscreen, Motorcycle Windshield)NegotiableMOQ: 1
-
GE WR 60*10185 DC Evaporator Fan MotorUS$ 5 - 10MOQ: 400 Pieces
-
Motor Manufacturing in ChinaUS$ 20 - 500MOQ: 10 Pieces
-
Single Use Thermometer Label for Small Electric Motors / 1 LevelUS$ 63 - 125MOQ: 30 Pieces
-
Pump Electric MotorUS$ 1 - 50MOQ: 100 Pieces
Recommended Categories
Explore top categories and find suppliers for your specific needs-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.