Home > Products > Ventilator > DP301 CO2 Absorber China
DP301 CO2 Absorber China
- 10000 Set / Sets per Month
- qingdao
- T/T PayPal Other
Product Details
Place of Origin: | China |
Product Description
DP301 CO2 Absorber
1 Inspiration connector: It supplies the gas that inhaled by patient. Pipeline exclusively used at patient end is provided together with the machine; connect one end (with filler) of the thick corrugated hose to this connection (total 2 thick corrugated pipelines), and another pipeline to expiratory connector.
2. Expiration connector: The gas exhaled by patient enters breathing circuit through this connection. Pipeline exclusively used at patient end is provided together with the machine; connect one end (without filler) of the thick corrugated hose to this connection; and another pipeline to inspiration connector
3. Manual bag connector: The manual bag will be connected with this connector under Manual working status.
4. Manual / Ventilation Handle: the respiratory management system is in machine-controlled status if the switch handle is in vertical position; and when the switch handle is rotated to horizontal position, the respiratory management system is in manual status
5. APL Valve: under manual mode, the range is 0.2kPa-6.0kPa. The color means the pressure range, green color means low pressure, red means high pressure, yellow is middle pressure. Clockwisely rotate to close, counterclockwisely rotate to open.
6. Expiration phase valve: The gas exhaled by patient goes through this valve. Therefore, when patient exhales, this valve is raised up. You can open this valve by rotating the transparent cover counterclockwise to perform cleaning and sterilization. The flake is fragile within the cover; caution should be taken to pick up and put down gently.
7. Airway pressure gauge: display airway pressure in real time. The unit is Kpa, range is -2-10KPa.
8. Inspiration phase valve: The air inhaled by patient goes through this valve. Therefore, when patient inhales, this valve is raised up. You can open this valve by rotating the transparent cover counterclockwise to perform cleaning and sterilization. The flake is fragile within the cover; caution should be taken to pick up and put down gently.
9. Driving gas inlet of bellows: This inlet is connected to gas outlet of bellows through a corrugated hose, refer to Figure 5-6.
10. Fresh gas inlet: This inlet is connected to fresh gas outlet on the rear of anesthesia machine via a corrugated hose, refer to Figure 5-2.
11. Airway pressure sampling port: this port is connected to pressure sampling connection at the rear of anesthesia machine via a hose of Φ6 (mm), refer to Figure 5-2.
12. Fixing bolts: when connect breathing circuit arm with breathing circuit, this bolt is used to fix the breathing circuit.
13. Canister: used to absorb CO2 that patient exhales, the volume of each soda lime canister is 1000mL; the canister is made of Polycarbonate, bearable high temperature, and not easily fragile; the canister edge is sharp, it is easily to seal and prevent the small soda lime grains into the seal ring.
14. Canister fixing handle: counterclockwisely rotate this handle is to open the canister, clockwisely rotate to tightly fix the canister.
15. Exhausted gas outlet: the outlet is 22mm cone type, and can be rotated at 360°.º
16. Hock: used to hung the respiratory pipelines only.
17. Air lock: there are 2 pcsΦ4 (mm) sampling pipelines, insert the white and transparent into the left port, insert the blue and transparent into the right port. Connect another ends with sampling connector of pressure difference flow sensor, sample the flow rate and calculate the tidal volume and minute ventilation.
Dolphinmed is one professonal producer of ICU ventilator, anesthesia machine, medical air compressor, anesthesia vaporizer, anesthesia ventialtor, veterinary anesthesia machine, etc. Dolphinmed are committed to provide the more perfect products and service for clients, to be the most valued medical equipment enterprise.
Contact Us
- Shandong Dolphinmed Technology Co., Ltd.
- Contact nameMike Wong
- Phone86-10-53367875
Anesthesia Machine | Ventilator | Anesthesia Vaporizer | Accessories |
- Operating table
- Operating table Orthopedics / surgery / gynecology / neurosurgery
- Hospital Otolaryngology diagnosis and treatment table
- Surgical laryngoscope
- Medical surgical microscope
- Medical magnifying glass Surgical magnifying glass
- Surgical magnifying glass Medical magnifying glass
- Potent Medical Devices Surgical Instruments Urology diagnostic screening procedure uroflowmetry uroflowmeter For urinary tract function
- 65W Potent Medical Equipment Surgical Instruments Urology Thulium Fiber laser For lithotripsy BPH
- 90W Potent Medical Instruments Urology lithotripter Surgical Holmium yag laser For Stone BPH Ablation ureteroscope
- 160W Potent Medical Devices Surgical Instruments Urology Thulium Holmium laser For BPH Holep with fiber
- Potent Medical Equipment Urology lithotripsy holmium laser For Stone prostate surgery
- Electric gynecological examination bed Private surgical beauty bed
- Operating microscope
- Bipolar Coagulation Forceps Head Medical Equipment Parts Universal Surgical Knife Surgical Scalpel MIM Surgery Forceps Head Surgical Instruments OEM
- Orthopedic sports medicine implants ACL Endobutton Fixation Device
- Surgical Clamps Forceps Head Surgical Instrument Accessories Metal Powder Injection Moldingmim Metal Structural Parts Surgical Instrument Parts
- Forced-air Warming System
Popular Searches
Find Similar Products By Category
- Health & Medical > Medical Devices > Surgical Instruments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Mike Wong
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-