Home > Products > Hot Water Products > PHNIX DC Inverter Heat Pump Air Source Heat Pump for Room Heating/Cooling with ErP Energy Label
PHNIX DC Inverter Heat Pump Air Source Heat Pump for Room Heating/Cooling with ErP Energy Label
- 5000 Unit / Units per Month
- Guangzhou China
- T/T Credit Card
You May Like
-
PHNIX Vertical Fan Coils with Galvanized and Glass Panel Design for Room Heating/Cooling
-
PHNIX H15 DC Inverter Heat Pump/Air Source Heat Pump with Refrigerant R410a
-
12P EVI High Temp Hot Water for 80 C Hot Water-Air Source Heat Pumps
-
12P EVI High Temp Hot Water for 80 C Hot Water-Air Source Heat Pumps
-
10P EVI High Temp Hot Water for 80 C Hot Water-Air Source Heat Pumps
-
10P EVI High Temp Hot Water for 80 C Hot Water-Air Source Heat Pumps
Product Details
Brand Name | PHNIX | Place of Origin | Guangdong, China | |
Model Number | H8/15 | Certification | CB, CE, CSA, ROHS, UL | |
Type | Central Air Conditioners | |||
Voltage (V) | 230 | Power (W) | 1500 | |
EER | 4.8 | COP | 3.2 | |
Capacity (btu) | 61433 | Cooling/Heating | Cooling/Heating | |
Use | Room | Condition | New |
Product Description
PHNIX DC Inverter Heat Pump for Room Heating/Cooling with ErP Energy Label
PHNIX Inverter Heat Pump Series apply the international DC inverter technology which can not only increase the room temperature in a short time, but also control the temperature automatically. Then you can enjoy the comfortable life the units providing for you all time.
1. DC Inverter Technology With the use of inverter compressors, brushless DC fan motors and PFC control method, the units can regulate the running capacity at any time when they need to save energy. With no frequent start-ups and stop runnings, the units work in stable condition with high efficiency. The energy consumption is 30% less than that of common heat pump units.
2. High Accuracy of Temperature Control The units can change the operating frequency of the compressors automatically according to the room heating/ cooling demand. When the target room temperature is going to be reached, the units run at a lower frequency, and the temperature control accuracy can be 0.5oC.
3. Fast Heating Cooling When there is large difference between the actual room temperature and the unit setting temperature, the unit can run at higher frequency to make fast heating/cooling to increase/decrease the room temperature rapidly
4. Lower Noise Because there will be no frequent start-ups and stop runnings, and the units work in stable condition, the noise from the units can be reduced significantly.
5. Electric Utilities Benefits Because of the DC inverter high efficiency design, the units can reduce the load on electric utilities while running.
6. Room Thermostat By installing the room thermostat in your room, you can control both heat pump units and terminals together. A fast heating mode is available in winter, which starts fan coils and floor heating together to heat up rooms. (room thermostat specification: 230V, RS485 interface) |
1.MITSUBISHI Compressor DC inverter scroll compressor, with 20% higher energy efficiency than that of traditional fixed frequency one, works quietly(with minimum 40dB(A) noise level, in 5m distance ).
2.GRUNDFOS WATER PUMP Grundfos P-M rotor pump, with PWM speed control, power consumption is 80% less than that of traditional water pump, ensuring trouble-free running all year round.
3.INVERTER DRIVE Using digital signal processing chips and PMSM sinusoidal wave control method, the power factor reaches 95%, working voltage range is larger and the units realize 1Hz control accuracy.
4.Brushless DC Fan Motor The brushless DC fan motor could realize stepless speed running under system pressure, realizing more than 30% energy saving. | 5.PATENT HEAT EXCHANGER With strong countercurrent design, the PHNIX patent heat exchangers are conductive to improving the efficiency and reliability of heat pump.
6.FIN TYPE HEAT EXCHANGER Golden anti-corrosion aluminum fins specialized for heat pump, it is not easy to frost but easy to clean up, with durable lifespan of more than 10 years.
7.CAREL CPP CONTROLLER The CAREL CPP controllers with intelligent control and detection make the units more user-friendly.
8.ELECTRONIC EXPANSION VALVE DC inverter scroll compressor, with 20% higher energy efficiency than that of traditional fixed frequency one, works quietly(with minimum 40dB(A) noise level, in 5m distance |
CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS, REACH, NF414, EN14511-2:2011, AHRI, ISO9001, ISO14001, Six Sigma, Lean Production and Management
WHO IS PHNIX
PHNIX is the largest manufacturer of swimming pool heat pumps and heat pump water heaters in China.
With more than 2,000 national patents covering heat pumps and heat pump technologies, PHNIX has built up a complete heat pump industrial chain. Additionally, PHNIX has developed hardware and software for intelligent device control, allowing customers to customize their PHNIX devices according to their personalized requirements. PHNIX provides high-end users integrated energy-saving solutions and products including swimming pool dehumidifiers, swimming pool heat pumps, room heating heat pumps, and industrial heat pumps home and abroad.
As an international enterprise, PHNIX attaches great importance to high-end overseas markets, exporting more than 50 percent of its products to Europe, North America , Middle East, Australia, and other developed regions.
Know more please click here
Contact Us
- Aquart Electrical Appliance Co., Ltd.
Product Categories
Heating&Cooling | Home Dehumidifier | Hot Water Products | Industry&Agriculture Energy-Saving Solution |
Swimming Pool Heat Pumps | Ungrouped | Water purifier | water dispenser |
New Products
-
6P EVI High Temp Hot Water for 80 C Hot Water-Air Source Heat Pumps
-
Panasonic Air Source Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, REACH)
-
House Heating System Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS)
-
Copeland Compress Heat Pumps
-
Heat Pump Air To Water High Temperature ( EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL, C-TICK, CB, CCC)
-
Heat Pump Expansion Valve(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL, C-TICK, CB, CCC)
-
Tank For Air Source Heat Pump Water Heater(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, REACH)
-
25kw Air Source(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS, REACH)
-
Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)
-
Air Source Heating Pumps(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS, REACH)
-
Solar Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS, REACH)
-
Heating and Cooling Unit-High Efficiency Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS)
-
Air Source Heat Pump(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL, C-TICK, CB, CCC)
-
PHNIX Heat Pump
-
Heat Pump for Home Floor
-
Copeland Scroll Compressor Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, REACH)
-
PHNIX Heat Pump for Air to Water
-
Water Cooled Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS, REACH)
-
Copeland Scroll Compressor Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE)
-
Media heat pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, REACH)
-
Heat Pumps Air To Water High Temperature(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, DOE, CE, ETL, CETL, C-TICK, CB, CCC)
-
Air Water Heat Pump Guangzhou(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, REACH)
-
Low Ambient Temperature Air Source Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, REACH)
-
Heat Pump(CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS, REACH, EN14511-2:2011
Popular Searches
- portable air conditioner
- split air conditioner
- Air Conditioners
- Solar Air Conditioner
- Inverter Air Conditioner
- Mini Air Conditioner
- Split Type Air Conditioner
- air conditioner
- Air-conditioner
- mini cooler
- Solar Pest Control
- display cooler
- Duct Type Air Conditioner
- Cooling Air Conditioner
- Portable Air Cooler
- Movable Air Cooler
- mini split
- home air conditioning
- wall unit air conditioner
- Air Conditioner Ac
- Heating Ac
- solar air conditioning
- solar powered air conditioning
- hybrid solar air conditioner
- Mobile Air Conditioner
- Window Air Conditioner
- Home Air Conditioner
- Electric Air Conditioner
- Wall Split Air Conditioner
- Inverter Split Air Conditioner
Recommended Products
- foaming machine *** water circulation cooling machine
- melt - blown fabric cold air (cooling) device, industrial air - conditioning chiller
- melt - blown fabric circulating industrial air cooler
- large crusher cooling *** cooling fan
- melt - blown fabric cooling device (air cooler)
- variable-frequency air cooler for melt-blown fabric cooling
- powder coating cooler *** cold air blower
- melt - blown fabric variable - frequency circulating air cooler
- selection and matching of water-cooled circulating water screw units
- parameters of screw-type circulating water cooling unit
- working principle of water-cooled screw refrigeration unit
- water-cooled screw chiller unit, manufactured by chuanbensi ***
Find Similar Products By Category
- Home Appliances > Air Conditioning Appliances > Air Conditioners
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile