Fluke 355 True RMS 2000 A Clamp Meter
Fluke 355 True RMS 2000 A Clamp Meter
Electrical Specifications | ||
Current measurement DC and AC 10 Hz to 100 Hz |
Range |
40 A / 400 A / 2000 A / 1400 AC rms |
Resolution |
10 mA / 100 mA / 1 A |
|
Accuracy |
A: 1.5% rdg + 15 digits |
|
Trigger level for Inrush |
0.50 A / 5.0 A / 5 A |
|
Trigger level for Hz filter OFF |
2.50 A / 2.5 A / 8 A |
|
Trigger level for Hz filter ON |
0.50 A / 2.5 A / 8 A |
|
Crest Factor (50/60 Hz) |
Range |
40 A / 400 A / 2000 A / 1400 AC rms |
Crest Factor1 |
2 @ 33 A, 2.4 @ 27 A |
|
Current measurement AC 100.1 Hz to 1 kHz |
Range |
40 A / 400 A / 2000 A; 1400 AC rms |
Resolution |
10 mA / 100 mA / 1 A |
|
Accuracy |
10 A: 3.5% rdg + 15 digits |
|
Trigger level for Inrush |
0.50 A / 5.0 A / 5 A |
|
Trigger level for Hz filter OFF |
2.50 A / 2.5 A / 8 A |
|
Trigger level for Hz filter ON |
0.50 A / 2.5 A / 8 A |
|
Voltage measurement DC and AC 10 Hz to 100 Hz |
Range |
4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC |
Resolution |
1 mV / 10 mV / 100 mV / 1 V |
|
Accuracy |
1% rdg + 10 digits |
|
Trigger level for Hz filter OFF |
0.25 V / 6 V |
|
Trigger level for Hz filter ON |
0.25 V / 6 V |
|
Voltage measurement AC 100.1 Hz to 1 kHz |
Range |
4 V / 40 V / 400 V / 600 V ac rms |
Resolution |
1 mV / 10 mV / 100 mV / 1 V |
|
Accuracy |
3% rdg + 10 digits |
|
Trigger level for Hz filter OFF |
0.050 V / 0.25 V / 6 V |
|
Trigger level for Hz filter ON |
0.050 V / 0.25 V / 6 V |
|
Ohms measurement |
Range |
4 kΩ / 40 kΩ / 400 kΩ |
Resolution |
0.1 Ω / 1 Ω / 10 Ω / 100 Ω |
|
Accuracy |
1.5% + 5 digits |
|
Continuity beeper |
On at ≤ 30 Ω |
|
Frequency measurement |
Measurement range |
5.0 Hz to 1 kHz |
Resolution |
0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) |
|
Accuracy – 5.0 Hz to 100 Hz |
0.2% + 2 counts |
|
Accuracy – 100.1 Hz to 1 kHz |
0.5% + 5 counts |
|
Trigger level |
Refer to current and voltage tables |
|
1. Add 2% to error spec for CF > 2 | ||
General Specifications | ||
Batteries |
Six 1.5 V AA NEDA 15 A or IEC LR6 |
|
Battery life (with typical usage, backlight off) |
100 hours |
|
Test leads |
Rated to 1000 V |
|
Weight |
.814 kg (1.8 lb) |
|
Jaw size |
58 mm (2.28 in) |
|
Dimensions (L x W x D) |
300 x 98 x 52 mm (12 x 3.75 x 2 in) |
|
Safety rating |
IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
|
Environmental Specifications | ||
Operating temperature |
32°F to +122°F (0°C to +50°C) |
|
Storage temperature |
-4°F to 140°F (-20°C to +60°C) |
|
Operating humidity |
0 to 95% (non-condensing) |
|
Operating altitude |
2000 m |
|
Storage altitude |
10,000 m |
|
IP rating |
42 (indoor use only) |
|
Drop test requirements |
1 m |
|
EMI, RFI, EMC |
FCC part 15, IEC/EN 61326-1:1997 class B |
|
Temperature coefficients |
Current |
0.1% of reading per °C outside 22°C to 24°C |
Voltage |
0.1% of reading per °C outside 22°C to 24°C |
|
Send Inquiry to This Supplier
You May Also Like
-
LC14B Handheld Portable Digital Clamp MeterUS$ 13 - 17.5MOQ: 10 Pieces
-
LC14D Handheld Portable Digital Clamp MeterUS$ 30 - 35MOQ: 10 Pieces
-
LC15A Handheld Portable Digital Clamp MeterUS$ 6.5 - 10MOQ: 10 Pieces
-
LC15B Handheld Portable Digital Clamp MeterUS$ 7.5 - 10.5MOQ: 10 Pieces
-
LC15C Handheld Portable Digital Clamp MeterUS$ 9 - 11MOQ: 10 Pieces
-
LC15D Handheld Portable Digital Clamp MeterUS$ 10 - 13MOQ: 10 Pieces
-
Fluke 365 Detachable Jaw True RMS AC/DC Clamp MeterUS$ 228 - 243MOQ: 1 Piece
-
Fluke 771 Milliamp Process Clamp MeterUS$ 615 - 708MOQ: 1 Piece
-
Fluke BT510 Battery AnalyzerUS$ 3734 - 3986MOQ: 1 Piece
-
Fluke BT510 Battery AnalyzerUS$ 3734 - 3986MOQ: 1 Piece