Home > Products > constant temperature&humidity chamber > Pressure Aging Testing Chamber for Braking Systems
Pressure Aging Testing Chamber for Braking Systems
- 23 Piece / Pieces per Month
- T/T L/C D/P D/A
- 7 days
Product Details
Brand Name: | ASLI | Place of Origin: | China | Model Number: | PCT - 35 |
Product Description
Pressure Aging Testing Chamber for Braking Systems
High-temperature cooking apparatus (PCT chamber ) is to achieve a high temperature, pressure , humidity and other conditions of accelerated aging test box is special pressure equipment, greatly speeding up the aging of the customer 's understanding of the product .
Model : PCT - 35
Specification: []
Inner dimensions : 300*450 mm (*D) circular chamber
Carton Size : 660*950*600 mm (W*H*D)
Inner material : SUS304 # stainless steel material ; Carton of paint .
Pressure Cooker Test (PCT)/Performance:
1.Temperature range :. 100 celsius degree ~ 132 celsius degree can be set arbitrarily .
2.humidity range :. 100percent RH ( saturated vapor humidity ) .
3.Pressure range : 0.0Kg/cm2 ~ 3.00Kg/cm2 absolute pressure ; ( safety pressure capacity 3Kg/cm2 / G = 1
Environmental pressure +2 Kg/cm2)
4.Time range :. 0 ~ 1000H
5.temperature distribution : (+ / -) 2.0 celsius degree percent (100 celsius degree )
6.Warm-up time :. RT ~ 121 celsius degree for about 35 minutes
urization time :. 0.0Kg/cm2 ~ 1.00Kg/cm2 within about 35 minutes
PCT Saturated Steam Chamber/Control System:
1.microcomputer saturated steam temperature + time LED display controller , pressure + Analog display table.
2.The system meets the reliability of the high-pressure accelerated aging test specifications : CNS, ISO, JIS, ASTM, DIN, BS, IEC, NACE, UL, MIL ...
ntrol object : microcomputer automatic calculation + PID + SSR saturated steam temperature control .
4.Control : microcomputer control.
5.Temperature control accuracy : (+ / -) 0.5 celsius degree .
6.Analytical accuracy : 0.1 celsius degree .
ure control accuracy : (+ / -) 0.15KG.
8.Cycle ways : natural convection steam cycle mode
9.Temperature sensors : (RTD) PT-100 ( platinum resistance )
10.Heating heater : electric heater insulation Temperature.
Contact Us
- Ai Si Li (China) Test Equipment Co.,Ltd
- Contact nameMs Rachel Lee
- Phone0086-769-22851843
- AddressJinHui Industrial Park, LiXin town,East City district Weihai,Shandong
constant temperature&humidity chamber | New product | walk-in Chamber |
- Fire prevention thermal imaging camera temperature measurement fire alarm forestry warehouse fire prevention
- USA original BENTLY 3500/44-01-00
- Carel refrigeration thermostat PJEZY0H000 cold storage controller
- Carel refrigeration thermostat PJEZS2P010 cold storage controller
- Carel refrigeration thermostat PJEZS0H000 cold storage controller
- Carel refrigeration thermostat PJEZS00000 cold storage controller
- Carel refrigeration thermostat PJEZC0P000 cold storage controller
- Carel refrigeration thermostat PJEZC0H000 cold storage controller
- Carel refrigeration thermostat PJEZC00000 cold storage controller
- Carel multi-parallel refrigerator controller MX30M25H00 temperature controller MPX PRO
- 698 photovoltaic protocol converter photovoltaic inverter power generation electricity consumption information collection
- New York Inspiration Temperature Sensor, Model 025W39721-302
- Repair of the exhaust temperature probe of the new York temperature sensor 639A0151H01 compressor condensing unit
- USA original bently nevada 330171-00-08-10-02-00 330173-00-05-10-12-00 330172-16-42-10-01-00
- USA original bently nevada 330130-040-00-00 330130-085-00-05
- USA original bently nevada 330106-05-30-10-02-00 330106-05-30-15-02-CN 330130-035-00-CN
- USA original bently nevada 330104-00-04-10-02-00 330103-11-19-10-02-00 330106-05-30-05-02-CN
- USA original bently nevada 330104-00-04-10-02-CN
- USA original bently nevada 330104-00-03-05-02-00
- USA original bently nevada 330103-12-25-10-01-00 330103-13-23-05-02-00 330103-15-23-05-02-CN
- USA original bently nevada 330103-05-15-05-02-00 330103-05-13-10-02-00 330103-10-20-05-02-CN
- USA original bently nevada 330103-02-12-05-02-CN 330103-03-12-05-02-00 330103-05-10-10-02-05
- USA original bently nevada 330103-00-20-10-02-00 330103-01-07-05-02-00 330103-02-07-10-02-00
- USA original bently nevada 330103-00-15-05-01-00 330103-00-18-05-02-05 330103-00-16-10-01-00
Popular Searches
- phone logger
- recorder
- thermometer hygrometer
- Bath Thermometer Strip
- data measurement
- recorders
- Temperature Data Logger
- digital thermostat
- fan thermostat
- control thermostat
- temperature recorder
- temperature humidity data logger
- data recorder
- temperature humidity sensor
- Humidity Data Logger
- Usb Data Logger
Find Similar Products By Category
- Measurement & Analysis Instruments > Temperature Instruments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ms Rachel Lee
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-