Pass Through Hospital Sterilizer , Horizontal Sterilization Medical Equipment
Certification:CE / ISO
Pass Through Hospital Sterilizer With Safety SS304 Chamber For Hospital CSSD
Specifications:
Chamber and process piping made of stainless steel AISI 304 Motorized Hinge Door made of stainless steel AISI 304 for durability and ease of cleaning Sensitive anti-finger trapping safety device Cladding made of stainless steel AISI 304 Suitable for floor level installation Direct and indirect steam to steam feed versions Easy service with frontal access Touch screen panel With stainless steel AISI 304 cart and trolley.Safety Features:
Emergency stop button located on the front panel, below the sterilizer control touch pad (Power Door Units Only). When pressed, immediately shuts off all outputs on the sterilizer. A key is used to reset the switch. Control lockout switch equipped on chamber door(s), senses when door seal is energized and tight against the door. Control prevents cycle from starting until the limit switch signal is received. If control loses appropriate signal during cycle, alarm activates, cycle aborts and chamber safely vents with a controlled exhaust. Chamber float switch activates alarm, aborts cycle and safely vents chamber with a controlled exhaust if excessive condensate is detected in the vessel chamber. Pressure relief valve limits the amount of pressure buildup so that the rated pressure in the vessel is not exceeded. Power door safety feature causes door drive to slip if the sliding door encounters an obstruction during its movement.Main Parameters:
|
Model |
MD-0.8 |
|
Door type |
Motorized Hinge Door |
|
Door number |
2 doors |
|
Chamber volume |
0.8m³ |
|
Chamber Size |
610*910*1450mm |
|
Overall Size |
1500*1900*1790mm |
|
Net Weight |
1400kg |
|
Steam |
35Kg/cycle |
|
Water |
280Kg/cycle |
|
Power(KVA) |
3KVA |
|
Sterilization temperature rage |
105°C to 134°C |
|
Sterilization time rage |
0---99 minutes |
|
Vacuum times |
0---9 times |
|
Drying time |
0---99 minutes |
|
Available test cycles |
Bowie & Dick test / Vacuum test |
Applications:
The hospital sterilizer family consists of fully automatic pre- and post-vacuum sterilizers , designed with the
highest quality to cover a large field of applications for hospitals CSSD, as well as operating room and medical centers.
Send Inquiry to This Supplier
You May Also Like
-
Creative Website & Names Graphic Design Service CompanyUS$ 69 - 199MOQ: 1 Unit
-
Whole Plant Equipment for Stainless Steel SinkUS$ 8 - 10MOQ: 1 Piece
-
SELLING SUDA MINI CNC ROUTER WITH ROTARY DIVICE ---SD3025SXNegotiableMOQ: 1 Set
-
Website DesignNegotiableMOQ: 1
-
H840*W430 Casting Iron PartsUS$ 1 - 100MOQ: 100 Pieces
-
2014 New Products On MarketUS$ 2 - 3.7MOQ: 2000 Pieces
-
Guard Patrol Products Website With Cloud-based SoftwareUS$ 60 - 85MOQ: 1 Set
-
OsCommerce WebsiteUS$ 1,760 - 1,800MOQ: 1 Piece
-
Composite Aluminum PanelUS$ 2 - 20MOQ: 1 Sheet
-
Brazilian Remy Hair Display Racks/curly Hair Displays/straight Human Hair Display FixtureNegotiableMOQ: 1