Integrated Thermocouple / Resistance
24px 'Microsoft Yahei', Arial, Helvetica, sans-serif; WHITE-SPACE: normal; ORPHANS: 2; COLOR: rgb(0,0,0); WORD-SPACING: 0px; PADDING-TOP: 5px; -webkit-text-size-adjust: auto; -webkit-text-stroke-width: 0px\\">Assembly type heat resistance temperature sensor matching with display instrument, measurement the surface temperature about liquid, gas and solid medium of range -200~600 ℃ , widely used in petroleum, chemical, machinery, metallurgy, electric power, textile, food, atomic energy, sectors and fields of science and technology.
24px 'Microsoft Yahei', Arial, Helvetica, sans-serif; WHITE-SPACE: normal; ORPHANS: 2; COLOR: rgb(0,0,0); WORD-SPACING: 0px; PADDING-TOP: 5px; -webkit-text-size-adjust: auto; -webkit-text-stroke-width: 0px\\">Assembly type heat resistance is usually composed of the temperature sensing element, fixing device and junction boxes and other major components.
24px 'Microsoft Yahei', Arial, Helvetica, sans-serif; WHITE-SPACE: normal; ORPHANS: 2; COLOR: rgb(0,0,0); WORD-SPACING: 0px; PADDING-TOP: 5px; -webkit-text-size-adjust: auto; -webkit-text-stroke-width: 0px\\">
24px 'Microsoft Yahei', Arial, Helvetica, sans-serif; WHITE-SPACE: normal; ORPHANS: 2; COLOR: rgb(0,0,0); WORD-SPACING: 0px; PADDING-TOP: 5px; -webkit-text-size-adjust: auto; -webkit-text-stroke-width: 0px\\" class=\\"p0\\">
24px 'Microsoft Yahei', Arial, Helvetica, sans-serif; WHITE-SPACE: normal; ORPHANS: 2; COLOR: rgb(0,0,0); WORD-SPACING: 0px; PADDING-TOP: 5px; -webkit-text-size-adjust: auto; -webkit-text-stroke-width: 0px\\" class=\\"p0\\">Code insulation resistance with copper resistance should not be less than 50
Cold insulation test voltage of resistance to 10~100V DC.
Self heat effect: platinum resistance allows the maximum current through the 5mA, the resulting temperature less than 0.3 ℃.
Thermal response time: the temperature step changes, the output variation of the thermal resistance and equivalent to the step change of the 50%, the time required, called response time of heat, represented by τ 0.5
Thermal resistance time constant
Nominal pressure thermal resistance: generally refers to the protection of pipe can bear at the operating temperature of the static pressure without rupture.
Heat resistance: minimum insertion depth shall not be less than 8-10 times its protective casing diameter.
Insulation resistance: when the ambient air temperature 15 - 35 ℃, relative humidity below 80%, the insulation resistance of 20000000000000 ohm (voltage 100V). With the insulation resistance splash-proof junction box shall be 2000000000000 euro (voltage 100V) thermal resistance temperature sensor at 0 ℃ resistance value (R0) and at 100 ℃ resistance value (R100) ratio: ratio = R100 / R
Index number Pt10, Pt100; R100 /R0 =1.3850 + 0.001
Index number Cu50, Cu100; R100 /R0 =1.3850 + 0.002
24px 'Microsoft Yahei', Arial, Helvetica, sans-serif; WHITE-SPACE: normal; ORPHANS: 2; COLOR: rgb(0,0,0); WORD-SPACING: 0px; PADDING-TOP: 5px; -webkit-text-size-adjust: auto; -webkit-text-stroke-width: 0px\\">
Send Inquiry to This Supplier
You May Also Like
-
Pressure Transmitters Rosemount Pressure TransmittersNegotiableMOQ: 1 Piece
-
Explosion-Proof Pressure Transmitter CT4 Certified for Hazardous Industrial AreasNegotiableMOQ: 50 Pieces
-
Rosemount 644 Profibus PA TransmitterUS$ 200 - 500MOQ: 1 Piece
-
Pressure TransmitterNegotiableMOQ: 2000 Pieces
-
Tuning Fork Level Switch With Good Performance and StabilityNegotiableMOQ: 1 Roll
-
Pressure Sensor Hirschmann Local WholesaleUS$ 18.00 - 35.00MOQ: 1 Piece
-
Krohne ConverterNegotiableMOQ: 1
-
Smart Pressure Level TransmitterNegotiableMOQ: 1 Set
-
Stable Performance Factory Directly Digital Pressure Gauge of SUPCONUS$ 400 - 600MOQ: 1 Case
-
Water Pressure Switch Oil PressureUS$ 36 - 39MOQ: 1 Piece