Home > Products > Composite Polymer Insulator > 63kV Suspension Type High Tension Insulators Lightweight High Performance
63kV Suspension Type High Tension Insulators Lightweight High Performance
- 0 Kilogram / Kilograms per Month
- T/T L/C D/P D/A
- 7 days
Product Details
Brand Name: | Changgong | Place of Origin: | China | Model Number: | FXBW-63/100-940 to FXBW-63/120-1066-YS |
Product Description
Certification:ISO 63kV type test report and 63kV design test report
63kV Suspension Type High Tension Insulators Lightweight High Performance
Specifications:
Dimensions and Characteristics of 63kV composite high tension insulators
Figure. No | Model | Rated Voltage | Specified Mechanical Load | Coupling Size | Section Length | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) |
1 Min Wet Power Frequency Withstand Voltage |
Weight (for Reference) |
kV |
kN |
H mm |
L mm |
≥ kV |
≥ kV |
kg |
|||
1.11-1 | FXBW-63/100-940 | 63 | 100 | 16 | 940±15 | 2200 | 410 | 185 | 3.7 |
1.11-1 | FXBW-63/120-940 | 63 | 120 | 16 | 940±15 | 2200 | 410 | 185 | 3.7 |
1.11-1 | FXBW-63/100-870-A | 63 | 100 | 16 | 870±15 | 1920 | 410 | 185 | 3.3 |
1.11-1 | FXBW-63/120-870-A | 63 | 120 | 16 | 870±15 | 1920 | 410 | 185 | 3.3 |
1.11-2 | FXBW-63/100-870-B | 63 | 100 | 16 | 870±15 | 2000 | 410 | 185 | 3.6 |
1.11-2 | FXBW-63/120-870-B | 63 | 120 | 16 | 870±15 | 2000 | 410 | 185 | 3.6 |
1.11-3 | FXBW-63/120-1066-YS | 63 | 80 | 16 | 1066±15 | 2800 | 410 | 185 | 4.5 |
Description:
1, 63kV composite high tension insulators are widely used in overhead transmission lines and substations.
2, Dead end fittings are up to the requirements from the clients, usually we use ball, socket, tongue, clevis for suspension insulators with forged steel. The dimensions and coupling size can be exactly according to the specification requirements from the utilities.
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
5, All our insulators were type tested and design tested in accordance with IEC61109, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
Applications:
1, 66kV(63kV) overhead transmission power lines.
2, 66kV(63kV)substations
Competitive Advantage: