Product Details
Brand Name: | ONE | Place of Origin: | China | Model Number: | FI-20248 |
Product Description
Certification:CE/ROHS/FCC/SGS
1 Years warranty low frequency UPS solar inverter 48v 220v pure sine wave 2kw solar inverter
FI-20248
Top One VS Other inverter factory
Strong loading capacity, which provides the true onetime soft start.
Top One: Helped by the highly optimized circuit structures, original electronic components and high-tech DSP program, full range of all our models can achieve maximum power loading by only onetime soft start. For example, 2000W inverter can onetime start directly with 2000W power loading.
Others: Due to the limitations of hardware and software technology, the loading way is gradually increasing. For example, to start a 1000W loading, their inverter requires 200W + 300W + 500W to superimpose the loading to 1000W.
Model | FI-102 | FI-152 | FI-202 | FI-302 | FI-402 | FI-502 | FI-602 | |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | |||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | ||||||
AC Mains input range | 170-275VAC (220/230/240VAC)±4% | |||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | |||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | ||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | |||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | |||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | |||||||
Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm | |||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | |||||||
Short circuit protection | Automatic shutdown | |||||||
Output | Transfer efficiency | ≥90% | ||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | |||||||
Output frequency | 123 | |||||||
Output wave form | Pure sine wave | |||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | |||||||
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | |||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | ||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | ||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | |||||||
Other | Transfer time | ≤5ms | ||||||
Display | LCD Display with function buttons | |||||||
Cooling system | Intelligent cooling fan control system | |||||||
≤42℃ slow fan, ≥45℃ fast fan | ||||||||
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) / | ||||||
Deep sulphation cycle 15.5 for 4 hrs | ||||||||
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option | |||||||
3 Stages charging | Boost charging, direct charging, float charging | |||||||
AC over charge protection | Battery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop charging after 60s alarm | |||||||
Working mode (Optional) |