Product Details
Brand Name: | Calin | Place of Origin: | China | Model Number: | DDSY168-S |
Product Description
Certification:CE/SABS/IEC
Surge Safe Din Rail Kwh Meter Single Phase , Anti Tamper STS Prepaid Meters
The DDSY168-S is a compact, two wire, keypad-based prepayment electricity meter which comprises two parts, the Metering Control Unit ( MCU), or main meter, and the Customer Interface Unit (CIU).
Consumer interaction with the meter and access to meter information (such as a low credit warning, energy consumption, and load contactor status) are available using the keypad and LCD display on the CIU. The CIU is the customer’s only interface with the meter, and is a compact unit with a user-friendly keypad and display. It is usually installed in a convenient location in the consumer’s home - remote from the MCU, and is connected to the MCU with a pair of communications wires.
The MCU contains all critical metering, number decryption and load control functionality. It operates independently and is immune to any form of tampering on the CIU interface. The MCU is usually installed in a secure, locked enclosure, typically a pavement kiosk or pole-mounted equivalent. It is outside the consumer’s home to facilitate easy inspection by the utility at any time and to reduce the opportunity of fraud by tampering. As an option, the MCU can be supplied with its own LCD display and keypad, which allows the utility to view important meter parameters without the need for an interrogation tool.
The DDSY168-S is built with surge arrestor that is capable of sustaining up to 16kV line surges and lightening and also available with options for SMPS that allows the mete to operate under extrem low voltage down to 60V or even below.
Major Features
1) 20 digits STS standard compliant
2) Adjustable power limit, low credit warning
3) Programmable emergency credit and disconnection / reconnection time
4) Unidirectional measurement of reverse energy (SRE)
5) Fraud protection : double line measurement for neutral missing
6) Diagnostic LED indicator
7) High surge withstand capability for areas prone to lightning or other line surges
User Benefits
a) Easy and low cost to install due to compact and slim-line design
b) Stable and secure communication between MCU and CIU
c) Utility can make payment control settings with the meter, power limit, muti-rate, tariff plans, etc.
d) Double insulation for consumers\' safety
Specifications:
Nominal voltage Un |
220/230/240 V |
Limited voltage |
70%~120%Un |
Nominal frequency fn |
50-60Hz+5% |
Basic current(Ib) |
5-10A |
Maximum current(Imax) |
60-100A |
Starting current(Ist) |
20mA |
Active energy constant |
1000imp/kWh |
Accuracy as Active energy to IEC62053‐21 |
Class1.0 |
Power consumption in Voltage circuit |
<2W <8VA |
Power consumption in current circuit |
<1VA |
Operating temperature |
25℃ to+70℃ |
Storage temperature |
40℃ to+85℃ |
Insulation level |
4kV rms for 1min |
Impulse voltage withstand |
8kV, 1.2/50 μs |
Air discharge |
16kV |
Immunity to HF fields |
|
80MHz to 2GHz with load |
10V/m |
100kHz to 1GHz without load |
30V/m |
Fast transient burst test |
4kV |
Meter shell Protection Rate |
IP54(IEC60529) |
Insulation System Classification |
Protective Class II |
Contact Us
- Shenzhen Calinmeter Co,.LTD
- Contact nameMr. Edward
- Phone86-755-23012661
- AddressBlock 3 Chaohuilou Inustrial Park, Longhua, Shenzhen, China Weinan,Shaanxi
- Hydrogen energy stack 3000W
- Hydrogen Bottles 5L,9L,12L
- Hydrogen Universal Controller
- Hydrogen energy stack 200W
- Hydrogen energy stack 500W
- Hydrogen energy stack 1000W
- Hydrogen energy stack 1500W
- Hydrogen energy stack 2000W
- EST-101A cell phone signal detector
- 808LA Cell phone signal jammer with high power
- NEMA 23 Servo Stepper Motor With 15N Max Axial Force Insulation Class B CCW Rotation
- Impulse Voltage Generator Test , AC Peak Measures , Reference Impulse calibrator
- CE Skymen Multi Frequency Ultrasonic Cleaner Stainless Steel 360 Liters
- Automatic Home Robot Vacuum Cleaner , Automatic Charging Station
- Portable rechargeable Floor Robot Vacuum Cleaner , Automatic floor mopping vacuum cleaner
- Stability CX Series slide inclinometer Disaster Monitoring System
- 10 I/O Micro PLC Programmable Logic Controller Basic Logic Control Instruction
- 128MB ROM 7\" TFT LCD Touch Screen HMI ARM9 400MHz CPU LED Backlight
- Waterproof electrical junction boxes , Three Gang Wing plastic electrical box
- Cast Aluminium Led Lighting Panels 12W SMD3528 135LEDS 205mm 2700 - 7000K Color
- Magnification 7.0X - 45X (90X) Gemology Microscope With 0-40 degree incline
- Laboratory Desktop Gem Stereo Microscope with Polariscope system
- 45W recessed LED Panel Light , indoor led panel lighting
- 5Ft 24W T8 Double Sided LED Tube IP 50 , SMD 3014 LED Ceiling Tube Lights
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Batteries > Fuel Cells
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Mr. Edward
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-