Home > Products > Sodium Hypochlorite Wastewater Treatment > Automatic Large Type Sodium Hypochlorite Wastewater Treatment For Sewage Plant
Automatic Large Type Sodium Hypochlorite Wastewater Treatment For Sewage Plant
- 0 Ton / Tons per Month
- T/T L/C D/P D/A
- 7 days
Product Details
Brand Name: | CNJY | Place of Origin: | China | Model Number: | CNJY-S |
Product Description
Certification:IS9001
Automatic Large Type Sodium Hypochlorite Wastewater Treatment For Sewage Plant
Generation principle:
The revolutionary CNJY-S series sodium hypochlorite generator is a newly and for on-site product of NaClO equipment and use for all kinds of needed NaClO disinfected. The sodium chloride solution under the certain voltage effect of the cell, a series of electrochemical reaction within the cell and the resulting solution is the NaClO solution. The main process can be simplified as follows:
NaCl+H2O+DC→NaClO+H2 ↑
The electrode reaction:
anode:2Cl--2e→Cl2
cathode:2H++2e→H2
solution:2NaOH+Cl2→NaCl+NaClO+H2O
Product system:
Brine preparation part: Including water softener, dissolving tank, salt feeder, mixing
system , etc.
Generation Part : Including Generator, Heated Exchange , Rectifier , Control Cabinet , etc.
Storage Tank Part : Including NaClO tank , blower fan , Level gauge , Hydrogen gas detector , etc
Delivery Part: dosing Pump, flow meter, residual chlorine detector, etc
The advantage analysis of on-site sodium hypochlorite
Compared with traditional disinfection methods:
Water sewage treatment plant 60000 T/D, available chlorite dosing quantity 3 PPM, need 180kg everyday.
Disinfection method | On-site | commercial | UV | |
Making process | It produce a solution of strengths 0.8% and the only PH of 9 and making it less likely to cause scaling | By-product of the chlor-alkali industry, the concentration of 10%, containing excess alkali and harmful impurities | Generally within the ultraviolet fluorescent mercury released from plasma discharge. | |
attenuation | Without attenuation | Attenuation of 5% per day, and also cause excessive Chlorate in dinking water | Usually by the turbidity impact, gradually weakened life six months after the exposure time is short, there is no continuous disinfection capacity, and there may be a problem microorganisms resurrection light, preferably in the case of process water for immediate use, no secondary pipeline better raw water pollution and biological stability of the situation (generally require organic matter content of less than 10μg/L) | |
safety | Safety disinfection method, environmental non-toxic, liquid dosage | Dangerous articles. Risk during transport and storage and easily caused degradable when storage. Short time storage and high transport costs. Liquid dosing | Quartz tube require regular cleaning, heavy workload, each lamp should change the water. Easy to do radiation uniformly over the entire processing space, shaded area exposure | |
Disinfection by-products | Due to weak in chlorine oxidation ability, three material are less, and combined additive, ammonia, potassium permanganate, less by-products | The raw material is Industrial salt, which contain harmful impurities in drinking water and it is bad for health. | None | |
Economic analysis | The investment is a little higher in the early time, but the operation cost is low, and after three or four years it can pay your investment money back | Equipment cost is low, but the high cost of running, and the running costs can not be controlled | Early investment in small, high maintenance costs, large daily operating costs. | |
Dosing Accuracy | Dosing liquid low concentration, can accurately control the amount of chlorine | High concentration, difficult to precisely control the amount of chlorine, dosing hole easily plug fouling | Regular cleaning, the effect can not be controlled and also need regular to test water quality. |
Unit raw material consumption:
DC Power consumption : 4.5kW·h/Kg Cl2
Salt consumption :3.5 Kg / Kg Cl2
Daily energy consumption:
Daily power consumption :180 x 4.5 = 810kW·h
Daily salt consumption :180 x 3.5 = 630 Kg
The raw material price :
The average power price :0.6 RMB / kW.h
Edible salt price :0.8 RMB /kg
Daily operation cost :
electricity :810 × 0.6 = 486 RMB
Salt :630 × 0.8 =504 RMB
Daily operation cost:486 +504 =990 RMB / D
UV operati
Contact Us
- Shanghai Jiayu Environmental Technology Co., LTD
- Contact nameMiss. Sherry
- Phone86-21-61280157
- AddressXuhui District (East China University of Science and Technology Parks) Huajing Road 1305, Lane on th Yan'an,Shaanxi
- Polyfluoroalkanes Removal Resin
- Polyfluoroalkanes Removal Resin
- Polyfluoroalkanes Removal Resin
- Polyfluoroalkanes Removal Resin
- Polyfluoroalkanes Removal Resin
- Polyfluoroalkanes Removal Resin
- Polyfluoroalkanes Removal Resin
- Polyfluoroalkanes Removal Resin
- Polyfluoroalkanes Removal Resin
- Mixed Bed Ion Exchange Resin
- Mixed Bed Ion Exchange Resin
- Mixed Bed Ion Exchange Resin
Popular Searches
Find Similar Products By Category
- Environment > Waste Management
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Miss. Sherry
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-