110KV~220KV XLPE Wire Extra High Voltage Cables Underground Custom
High-voltage 110~220KV XLPE Cable
Brief introduction of the 110~220KV XLPE high-voltage cable products
1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC sheathed power cable.
2. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PE sheathed power cable.
Specific property for usage of 110KV~220KV XLPE high-voltage cable
1. Cable\'s conductor highest working temperature is allowed up to 90º C, and overload when meet an emergency is 130º C, When short circuit (in ≤ 5 seconds) the highest temperature is 250º C
2. When installing or laying cable, the ambient temperature should be less than -20º C, and have to give a preheat to cable.
3. The minimum bending diameter(in follow the table):
Note: In form, D0 is a real test value to cable\'s outer diameter.
4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) T=K× Core NO. × Section (kg), in formula, the coefficient K value should be: The copper core get 7, the aluminum core get 4.
5. Allowed biggest lateral-press P, when cable is being bent,
The single core cable is required P≤ 500kg/m. P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened.
6. Cable laying is not being restricted by drop.
| Type | YJLW02YJLLW02 |
| Specification | 240mm 2 ~3000mm 2 |
| Voltage | 110~220KV |
| Usage | Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure. |
| Type | YJLW02 YJLLW02 |
| Specification | 240mm 2 ~ 3000mm 2 |
| Voltage | 110~220KV |
| Usage | Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure. |
| Cable type Bending diameter |
Metal sheathed |
| After laying | 30D0 |
| During laying | 40D0 |
Send Inquiry to This Supplier
You May Also Like
-
Original CNC Fanuc PLC Keyboard A16B-2201-0101NegotiableMOQ: 1 Piece
-
High Quality Cnc System Controller A98L-0001-0568 Membrane Fanuc KeypadNegotiableMOQ: 1
-
Untested Scrap Recycle Computer Hardware Used Keyboard PartsNegotiableMOQ: 10000 Pieces
-
Air Conditioner Remote Control ButtonUS$ 0.01 - 0.5MOQ: 1000 Pieces
-
Waterproof Thin Film Membrane SwitchUS$ 0.056 - 0.16MOQ: 200 Pieces
-
KEYBOARDNegotiableMOQ: 3 Pieces
-
Customizable Compact Small Kiosk Industrial Keyboard With Optical TrackballNegotiableMOQ: 1 Piece
-
Full Color Outdoor Led Video Screen RentalNegotiableMOQ: 1 Piece
-
Flag Terminal Thermistor Temperature Sensor Probe 4300 For Industrial EquipmentNegotiableMOQ: 1 Piece
-
SECC / EGC Automotive Stamping Parts 1.0mm Thick For Lexus Auto DVD ChassisNegotiableMOQ: 1 Piece