Home > Auto, Motorcycle Parts & Accessories > Auto Electrical System > Car Battery > Portable Multiparameter Emergency Medical Supply Patient Monitors 8.4'' Human Voice Alarm

Portable Multiparameter Emergency Medical Supply Patient Monitors 8.4'' Human Voice Alarm

Portable Multiparameter Emergency Medical Supply Patient Monitors 8.4'' Human Voice Alarm photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
hb
Place of Origin:
China
Model Number:
PM001
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Brand Name hb
Place of Origin China
Model Number PM001
Delivery Time:7-15days
Certification:ISO

Portable multiparameter emergency medical supply Patient Monitors 8.4\'\' human voice alarm 1. Detailed Product Description: 1.8.4 inch color TFT display 2.Support 8 channel waves 3.Unique human voice alarm. 4.CE approved 5.18 months guarantee 2. Feature: 1 8” color TFT display, support 8 channel waves, 6 parameters. 2 Unique human voice alarm. 3 Rich screen layouts: Standard, big font, trend table, NIBP trend, ECG full lead, OxyCRG.. 4 Powerful storage: maximum 720 hour graphic and tabular trends of all parameters, up to 10000 NIBP review, 200 alarm event review, 2 hours of all waveforms. 5 System software can be upgraded through network. 6 Standard configuration: ECG, RESP, TEMP, NIBP, SpO2 7 Optional: Recorder, VGA. 3.Specification: Screen Size:8.4 inch ECG: Lead mode:I II III, AVR.VL.AVF.V GAIN:*0.25.*0.5.*1.*2(mm/mV) Hear rate:15-300 bpm(adult) 15-350bpm(pediatric) Resolution:1bpm Accuracy:+-1% Bandwidth: Diagnostic:0.05-130Hz Monitor:0.5-40Hz Surgery:1-20Hz Sweep speed:12.5mms, 25mm/s, 50mm/s Pacemaker rejection:Yes ST measurement Range:-2.0+-2.0mv Accuracy:+-0.02mv or +-10% which is greater Spo2: Measure range:0-100% Resolution:1% Accuracy:+-2% Resolution:1bpm Accuracy:+-3bpm NIBP: Work mode: manual, automatic, continuous Unit: mmHg, Kpa Measure range: adult: SYS:40-280mmhg DIA:10-220mmhg MEAN:20-240mmhg Pediatric:SYS:40-220mmhg DIA:10-160mmhg MEAN:20-170mmhg Neonatal:SYS:40-135mmhg DIA:10-100mmhg MEAN:20-100mmhg Resolution:1mmhg Accuracy: max mean error:+-5mmhg; max standard deviation:8mmhg Overpressure protection:0-300mmhg Degree of protection:BF.CF RESP: Measure range:Adult:0-120rpm pediatric.neonatal 0-150rpm Resolution:1 rpm Accuracy:+-2% TEMP: Channels:2 Measure range:0-50°c Resolution:0.1°c Accuracy:+-0.1°c(25-45c°) Recorder(optinal): Width:48mm Speed:25-50mm Channels:2
payment:TT, West Un
minimum order:

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Zaozhuang, Shandong, China

Recommended Categories

Explore top categories and find suppliers for your specific needs