Page 3-14 1E3C-E-MMB03-A01-00 3.1 Checking the Operation of Each Sensor 
1. How to adjust:         
Adjust the mode and sensitivity of the sensor.   
. There are two units: Light-emitting sensor and light-receiving sensor. All the adjustments are made on the Light-receiving sensor. 
1E4C-461E           
1E4C-442E           
1E4C-443E           
1E4C-444E           
1. Ensure that the selection switch on the back of the sensor indicates “D.ON.” 
. If not, switch it at “D.ON” using a slotted precision screwdriver. 
             
2            
Set the bottle containing enough solvent.     
3            
Slowly turning the sensitivity control knob located on the top from MIN. to Max., record the position where the operation indicating lamp (red LED) went out as A point. 
4            
Remove the bottle containing solvent, transfer it to another vessel, and then set the empty bottle. 
5            
Slowly turning the sensitivity control knob located on the top from A to MIN., record the position where the operation indicating lamp (red LED) went on as B point. 
. If the operation indicating lamp does not go on in spite of the fact that the knob reaches MIN., record the MIN. position as B point. 
6. Turn the sensitivity control knob to between A and B. 
             
. This concludes the adjustments. When setting the bottle containing solvent or an empty one, ensure that LED goes on as follows. With solvent: Green ON, Red ON Without solvent: Green ON, Red OUT 
1E3C-E-MMB03-A01-00 Page 3-15 3.2 Replacing the Consumable Parts 
3.2 Replacing the Consumable Parts       
3.2.1 How to Replace the Squeegee (Urethane Section) (For Cartridge Head) 
This part describes how to replace the squeegee (the urethane section). The replacement timing varies according to usage conditions; therefore, it should be replaced before bad printing due to a worn squeegee occurs. 
. Lifespan (Replacement timing) of urethane rubber A urethane rubber (with four edges) has a life of about 20,000 to 25,000 times. 
1. Check for wear and flaws in the edge of a urethane rubber by the touch. 

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Baoji, Shaanxi, China

Recommended Categories

Explore top categories and find suppliers for your specific needs