If it is not 0.2 MPa, loosen the nut and adjust it using the screw. 
         
After the adjustment, be sure to perform the printing pressure teaching. 
Name           
           
c          
Pressure gauge         
d          
Nut           
e          
Screw           
1D3C-439E         
Page 1-50 1E3C-E-MMB01-A02-00 1.5 Every-560-Hour Check (Once a Month) 
1.5.4 Checking the MR Unit (Before Operation) 
Tools           
           
Time required         
1 minute         
1. Check the supply air pressure c.    
. Required value range of supply air pressure  
0.49 MPa to 0.78 MPa        
. Ensure the air pressure is within the required  
value range.          
If it is out of the range, adjust it with the handle  
d so that it will be within the range.    
. How to use the handle        
           
1D3C-AB  3  1          
2          
1:  Unlock  2:  Adjust  3:  Lock      
2          
1D3C-415P  1  Pressure gauge      
1D3C-061P          
AAA0045B          
2. Check the water receiver e.      
. If the receiver is filled approximately one-half  
full of water, drain it.        
           
3          
1E3C-AC          
1E3C-E-MMB01-A02-00 Page 1-51     
1.5 Every-560-Hour Check (Once a Month)   
1.5.5 Checking the Process-Pump Air Pressure 
NOTICE This maintenance is carried out with the power supply switch ON. In performing a work inside the moving part, be sure to open the safety cover. (Opening the cover interrupts the power supply to the moving-part motor.) 
NOTICE Before checking the process-pump air pressure, choose wet process and suction OFF for the one-round cleaning mode (forward) in the cleaning data. After checking the air pressure, restore the cleaning data to the original one. 
1B4C-EEn-Ma-001         
SERVO           
) ON (           
           
)          
OFF (           
1D3C-418P         
UNLOCK           
1. Press         
+ [Mask cleaning].       
         
The <Cleaning> screen is displayed.   
         
The XY table travels toward your side.   
           
2          
Turn OFF the servo switch.     
3          
Open the front safety cover.     
4          
Open the center safety cover, and pull out the cleaning unit. 
To the next page         
Page 1-52 1E3C-E-MMB01-A02-00 1.5 Every-560-Hour Check (Once a Month) 
NOTICE In an initial state (of solvent), if the air pressure is too low, solvent cannot be sent from the process pump in spite of the fact that [Send out air of solvent] is pressed. 
1          
           
 Set the air pressure to 0.2 MPa (rather high) to send out solvent. 
2          
 Check that the discharged-solvent width is proper, at step 17. 
5. Press [Send out air of solvent].   
. The air in the solvent hose is purged.   
6. Return the cleaning unit into the main body. 
1E4C-EEn-MaMc-003       
7. Close the front and the center safety cover. 
SERVO           
OFF (           
           
) ON ( )         
8. Turn ON the servo switch.     
UNLOCK          
9. Press         
+ [Paper feed].         
. The paper soaked with solvent is rolled up. 
UNLOCK          
10. Press         
+ [Paper feed].         
. Ensure that the paper on the suction section 
           
1E4C-EEn-MaMc-003       
is dry.           
UNLOCK           
11. Press         
+ [Cleaning 1 step].       
UNLOCK           
12. Press         
+ [Yes].         
. The cleaning unit travels to the cleaning start 
position. To the next page     
           
1E3C-E-MMB01-A02-00 Page 1-53 1.5 Every-560-Hour Check (Once a Month) 
SERVO OFF ( ) ON ( )       
2          
1B4C-436E 1D3C-AB       
SERVO OFF ( ) ON ( )       
UNLOCK           
13. Press         
+ [Yes].         
. Solvent is sprayed on the cleaning paper, and the suction section raises. 
UNLOCK          
           
14. Press         
+ [No].           
. The cleaning unit returns to your side.   
15          
Turn OFF the servo switch.     
16          
Open the front and the center safety   
cover.           
17          
Check the width of the solvent discharged to the cleaning paper. 
           
. If the discharged-solvent width is not 30 mm ± 5 mm, open the front cover SW3 (cleaning) and adjust the regulator f. 
Name 3           
c          
Solvent-dispensing nozzle       
d          
Solvent           
e          
Cleaning paper         
4          
1D3C-439E         
           
. After the adjustment, perform steps 7 to 17 again. 
18          
Close the front and the center safety   
cover.           
19          
Turn ON the servo switch.       
20          
Press of the function keys.     
Page 1-54 1E3C-E-MMB01-A02-00 1.5 Every-560-Hour Check (Once a Month) 
1.5.6 Adjusting the Color Camera (SP80V Only) 
           
1. Press in the main menu.     
Machine           
adjust           
. The <Machine adjustment menu> screen is displayed. 
2. Press [Maintenance].       
. The <Maintenance menu> screen is displayed. 
. The mask should be removed beforehand.   
3. Press [Color camera calibration].   
. Following the message, change the supports and set the jigs upon initiation; upon completion, return the supports and remove the jigs. 
         

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Baoji, Shaanxi, China

Recommended Categories

Explore top categories and find suppliers for your specific needs