Independent Cooling Channel Design 100% Continuousness Output Ration VFD AC Drive
Certification:CE
KOC-P5 series frequency inverter
CE and ISO 9001 approved
promt delivery time
good after-sale service
reasonable price
KOC-G5/G5 series variable frequency inverter /drive (VFD)for fan and water pump introduction
power range:1.5kw~400kw(1.5kw3.7kw/5.5kw/7.5kw/11kw/15kw/18.5kw/22kw/30kw/37kw/45kw/55kw/75kw/93kw/
110kw/132kw/160kw/185kw/200kw/220kw/250kw/280kw/315kw/350kw/400kw)
Main features:
1.the screen of the keypad can display two kinds of datas,so you can observe two kinds of information at a time,such as the frequency,current,voltage,speed,PID data and so on.
2.independent cooling channel design.this is good for applications like printing,textile,cement and steel factories where severe environment exist.
3.mutiple control terminals,6DI,4DO,2AI,4AO,RS-485 support Modbus-RTU.
4instant power off continue running and speed tracking.
5.JOB key control, support user self-defined frequency jumping.
The technical specification of KOC- P5 series variable frequency inverter/drives(VFD)
|
model |
KOC-P5-110T4 |
|
gross weight |
it all depends |
|
dimension |
(wall-hooked or(cabinet stype) |
|
input voltage fluction |
3 phase 380 volts -15%~+10% (323~418 volts) |
|
input rated frequency |
50/60hz5% (47.5~63 hz) |
|
output ration |
100% continuousness |
|
output rated voltage |
max. output voltage is the same as the input voltage |
|
max. overload current |
120% 1min , 130% 6 secs |
|
control mode |
SVPWM control |
|
frequency range |
0~120 hz |
|
frequency accuracy |
digital command 0.01%(-10%~+40%) |
|
set frequency resolution |
digital command 0.01hz ; analogue command 0.1hz/60hz |
|
output frequency resolution |
0.01hz |
|
voltage/frequency feature |
34 fixed V/F features selectable, any V/F features can be set. |
|
acc/dec feature |
0.1~9999secs (acceleration and deceleration time set separately) |
|
brake torque |
125% with additional brake resistor |
|
frequency set signal |
0~10volts , 0~5volts , 4~20mA , 0~20mA |
|
protection |
over voltage, over voltage stalling, under voltage, current limit, over current ,overload ,overheat ,electronic terminal relay, data protection, under load precaution, loaded short circuit |
|
two lines LED display |
parameter set/ running display/ faults display/ function code/ data/ status |
|
working environmemt |
installation place: indoors, not higher than 1000m above sea level,without dust, corrosive air and direct sunlight. ambient temperature and humiditty: -10~40°c,20%~90%RH( without dewing) vibration: lower than 0.5g when below 20hz storage temperature: -20~+65°c
|
Send Inquiry to This Supplier
You May Also Like
-
High Accuracy NTC 10K 3950 Underfloor Heating Temperature Sensor TPE Injection Molded ProbeUS$ 0.7 - 1MOQ: 1000 Pieces
-
Professional Wireless DJ Audio Mixer - 6-Channel BT Compatible DJ ControlNegotiableMOQ: 1
-
2014 High Quality 1U Wholesale Home Power Amplifier E-200US$ 330 - 630MOQ: 1 Piece
-
New Design Monitor Speaker StandUS$ 7 - 8MOQ: 200 Pieces
-
9V3Ah LiFePO4 Battery for LED LampNegotiableMOQ: 100 Packs
-
Roto Mold Plastic Home LightNegotiableMOQ: 100 Sets
-
Power Amplifier 2.0 Channel Professional Power AmplifierUS$ 20 - 50MOQ: 100 Pieces
-
Multimedia Central SystemUS$ 90 - 150MOQ: 5 Sets
-
Dual 10'' Line Array Neodymium Driver HornUS$ 1 - 5,000MOQ: 1 Set
-
1500w Mini Fog Machine /smoke MachineUS$ 1 - 100MOQ: 1 Piece