Home > Industrial Equipment & Components > Filtration Equipment & Parts > Industrial Water Filter > Portable Multiparameter Emergency Medical Supply Patient Monitors 8.4'' Human Voice Alarm

Portable Multiparameter Emergency Medical Supply Patient Monitors 8.4'' Human Voice Alarm

Portable Multiparameter Emergency Medical Supply Patient Monitors 8.4'' Human Voice Alarm photo-1
Negotiable MOQ: 1 Set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
TM
Place of Origin:
China
Model Number:
PM001
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Brand Name TM
Place of Origin China
Model Number PM001
Delivery Time:3-5 working days
Certification:CE

Portable multiparameter emergency medical supply Patient Monitors 8.4'' human voice alarm

1. Detailed Product Description:
1.8.4 inch color TFT display
2.Support 8 channel waves
3.Unique human voice alarm.
4.CE approved
5.18 months guarantee

2. Feature:
1  8” color TFT display, support 8 channel waves, 6 parameters.
2  Unique human voice alarm.
3  Rich screen layouts: Standard, big font, trend table, NIBP trend, ECG full lead, OxyCRG..
4  Powerful storage: maximum 720 hour graphic and tabular trends of all parameters, up to 10000 NIBP review, 200 alarm event review, 2 hours of all waveforms.
5  System software can be upgraded through network.
6  Standard configuration: ECG, RESP, TEMP, NIBP, SpO2
7  Optional: Recorder, VGA.

3.Specification:
Screen Size:8.4 inch
ECG:
Lead mode:I II III, AVR.VL.AVF.V
GAIN:*0.25.*0.5.*1.*2(mm/mV)
Hear rate:15-300 bpm(adult)
15-350bpm(pediatric)
Resolution:1bpm
Accuracy:+-1%
Bandwidth: Diagnostic:0.05-130Hz
Monitor:0.5-40Hz
Surgery:1-20Hz
Sweep speed:12.5mms, 25mm/s, 50mm/s
Pacemaker rejection:Yes
ST measurement Range:-2.0+-2.0mv
Accuracy:+-0.02mv or +-10% which is greater


Spo2:
Measure range:0-100%
Resolution:1%
Accuracy:+-2%
Resolution:1bpm
Accuracy:+-3bpm


NIBP:
Work mode: manual, automatic, continuous
Unit: mmHg, Kpa
Measure range: adult: SYS:40-280mmhg
DIA:10-220mmhg
MEAN:20-240mmhg
Pediatric:SYS:40-220mmhg

DIA:10-160mmhg
MEAN:20-170mmhg
Neonatal:SYS:40-135mmhg
DIA:10-100mmhg
MEAN:20-100mmhg
Resolution:1mmhg
Accuracy: max mean error:+-5mmhg; max standard deviation:8mmhg
Overpressure protection:0-300mmhg
Degree of protection:BF.CF


RESP:
Measure range:Adult:0-120rpm
pediatric.neonatal 0-150rpm
Resolution:1 rpm
Accuracy:+-2%


TEMP:
Channels:2
Measure range:0-50°c
Resolution:0.1°c
Accuracy:+-0.1°c(25-45c°)
Recorder(optinal):
Width:48mm
Speed:25-50mm
Channels:2
 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Jiaxing, Zhejiang, China