Home > Instruments & Meters > Meter for Electricity > Multimeter > HT5100 Bench-type 600,000 Counts 4-Wire Digital Multimeter(DMM)

HT5100 Bench-type 600,000 Counts 4-Wire Digital Multimeter(DMM)

HT5100 Bench-type 600,000 Counts 4-Wire Digital Multimeter(DMM) photo-1
US$ 500 - 800 MOQ: 2 Sets
Key Specifications
Get Latest Price
Brand Name:
HENKI
Place of Origin:
China
Model Number:
HT5100
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Brand Name HENKI
Place of Origin China
Model Number HT5100
The HT5156 is a bench-type, dual-display digital multimeter with a price well worth its value. It provides a broad range of features and measurement functions which meet various requirements in manufacturing and R&D environments.
 
The 600,000 counts HT5156 provides real-time measuring and readback function. It also features high brightness/contract VFD, 4-wire resistance measurement technique and 0.02% DCV measuring accuracy. For those who need to control and take preset measurements with a PC, the built-in USB and RS-232C interfaces provide an easy connection between the PC and DMM. The USB and RS-232C interfaces can be controlled remotely via industry standard SCPI commands, which ensure an easy integration with different programming environments.
 
 
Product Feature
l   600,000 Counts Display
l   22 Built-in Measurement Function  DCV, ACV, DC+ACV, DCI, ACI, DC+ACI, 2Wohm, 4Wohm, Diode Test, Continuity Beeper, Capacitance, Frequency, Period. %Duty Cycle, Temperature, dB, dBm, Math(MX+B, %, 1/X), MAX/MIN, Auto Hold, REL, Compare
l   Auto or Manual Ranging
l   VFD Dual Display
l   0.02% DCV Accuracy
l   ACV Measuring Frequency Up to 100KHz
l   Current Measurement Range with High Energy Fuse Protection
l   AC or AC+DC True RMS
l   2000 Points Data-Logging Function
l   Selectable Measurement Rate
l   External Trigger Function
l   Standard RS-232C and USB interface
l   Option: GPIB(IEEE-488.2) interface

Electrical Specifications Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23°C ± 5°C & less than 75% relative humidity.  True RMS voltage & current accuracies are specified from 5 % to 100 % of range or otherwise specified. Maximum Crest Factor < 1.8:1 at full scale & < 3.6:1 at half scale, and with frequency components within the specified frequency bandwidth for non-sinusoidal waveforms.

 

DCV

 

Ohms (2W, 4W)

 

Range

Accuracy

 

Range

Accuracy1)

 

600.000 mV, 6.00000V, 60.0000V

0.02%+20d

 

600.000W

0.07%+20d

 

600.000V

0.04%+20d

 

6.00000kW

 

1000.00V

0.05%+20d

 

60.0000kW

0.1%+20d

 

Input Impedance: 10MW

 

600.000kW

 

 

 

6.00000MW

0.5%+60d

 

DC Current

 

60.0000MW

2.0%+60d

 

Range

Accuracy

Burden Voltage

 

Open Circuit Voltage: 1.2VDC typically (3VDC typically for 500W range)

 

600.000mA

0.15%+200d

0.11mV/mA (typical)

 

1)From 0% to 10% of range: Specified accuracy + 30d

 

6000.00mA

0.1%+200d

 

 

 

60.0000mA

0.15%+200d

1.8mV/mA (typical)

 

Diode Tester

 

600.000mA

0.15%+300d

 

Range

Accuracy

Test Current

Open Circuit Voltage

 

6.00000A

0.5%+200d

26mV/A (typical)

 

2.00000V

1%+10d

0.4mA (Typical)

3.5 VDC (Typical)

 

10.0000A 1)

0.5%+200d

 

 

 

1) ≤10A continuous, >10A ~ 20A for 30 second max with 5 minutes cool down interval

 

Continuity Beeper

 

 

 

Range

Accuracy

 

True RMS AC & AC+DC Voltage

 

600.000W

0.07%+90d+xW

 

Range

Accuracy 1)

 

 

 

20Hz -- 45Hz

 

Capacitance

 

600.000mV, 6.00000V, 60.0000V

1.5%+600d

 

Range

Accuracy 1)

 

600.000V, 1000.00V

Unspec'd

 

60.000nF

0.8%+30d

 

45Hz -- 300Hz

 

600.00nF

0.8%+30d

 

600.000mV

0.3%+200d

 

6.0000mF

1.5%+30d

 

6.00000V, 60.0000V

0.8%+200d

 

60.000mF

2.5%+30d

 

600.000V, 1000.00V

0.4%+400d

 

600.00mF

3.5%+50d

 

300Hz -- 5kHz

 

9.9999mF

5.0%+50d

 

600.000mV

0.3%+100d

 

1) Accuracies with film capacitor or better

 

6.00000V, 60.0000V, 600.000V

0.4%+400d

 

 

 

1000.00V  (@ 300Hz ~ 1kHz only)

0.8%+400d

 

Hz Line Level Frequency

5kHz -- 20kHz

 

Function Range

Sensitivity (Sine RMS)

Measurement Range

 

600.000mV

0.5%+200d

 

600mV

100mV

10Hz ~ 200kHz

 

6.00000V, 60.0000V

0.8%+200d

 

6V

0.6V

10Hz ~ 200kHz

 

600.000V

0.5%+200d

 

60V

6V

10Hz ~ 100kHz

 

1000.00V

Unspec'd

 

600V

60V

10Hz ~ 100kHz

 

20kHz -- 100kHz

 

1000V

600V

10Hz ~ 10kHz

 

600.000mV

2.5%+400d

 

600mA, 6000mA

300mA

10Hz ~ 10kHz

 

6.00000V, 60.0000V

4.0%+400d 2)

 

60mA, 600mA

30mA

10Hz ~ 10kHz

 

600.000V

Unspec'd

 

6A, 10A

3A

10Hz ~ 3kHz

 

1000.00V

 

Accuracy: 0.02%+4d

 

1) From 5% to 10% of range: accuracy % of reading (or in dB) + 1800d

 

 

 

2) From 10% to 15% of range: accuracy % of reading (or in dB) + 1000d

 

 

Hz Logic Level Frequency

 

Input Impedance: 10MW, 50pF nominal (80pF nominal for 500mV range).

 

Range

Accuracy

 

 

 

5.0000Hz--1.00000MHz

0.002%+4d

 

True AC & AC+DC Current

 

Sensitivity: 2.5Vp square wave

 

Range

Accuracy

Burden Voltage

 

 

 

50Hz – 60Hz

 

%Duty Cycle

 

600.000mA

0.5%+500d

0.11mV/mA (typical)

 

Range

Accuracy

 

6000.00mA

 

0.100% -- 99.990%

3d/kHz+20d

 

60.0000mA

1.8mV/mA (typical)

 

Input Frequency:  5Hz -- 500 kHz, 5V Logic Family

 

600.000mA

 

 

 

6.00000A

26mV/A (typical)

 

Temperature

 

10.0000A 1)

 

Range

Accuracy

 

40Hz – 1kHz

 

-100.0°C to 1000.0°C

0.3%+1.5°C

 

600.000mA

0.7%+500d

0.11mV/mA (typical)

 

-148.0°F to 1832.0°F

0.3%+3.0°F

 

6000.00mA

 

Thermocouple range & accuracy not included

 

60.0000mA

1.8mV/mA (typical)

 

 

 

600.000mA

 

Math Functions

 

6.00000A

26mV/A (typical)

 

dB, dBm, Math(MX+B, %, 1/X), Max/Min(Max, Min, Max-Min, Avg),

 

10.0000A 1)

 

REL, Hold, Compare, Filter, Store, Recall

 

1kHz – 10kHz

 

Display

5x7 dot matrix VFD Display

 

600.000mA

2.0%+500d

0.11mV/mA (typical)

 

Interface

Standard RS-232,USB. Optional GPIB(SCPI)

 

6000.00mA

 

Power Source

AC100/110/220/230V,±10%,50/60Hz

 

60.0000mA

1.8mV/mA (typical)

 

Dimension & Weight

262(W)x104(H)x367(D)mm, Approx. 4.4Kg

 

600.000mA

 

Accessories

HTL-502 x1

 

6.00000A

Unspec'd

26mV/A (typical)

 

Order Information

 

10.0000A 1)

 

HT5156

600,000 Counts Dual Display Digital Multimeter

 

1) ≤10A continuous, >10A ~ 20A for 30 second max with 5 minutes cool down interval

 

Opt-01

GPIB(IEEE-488.2) Interface

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Binzhou, Shandong, China

Recommended Categories

Explore top categories and find suppliers for your specific needs