Air to Water Heat Pump Heating and Cooling Systems Monobloc
Certification:CE EN14511
Air to water heat pump heating and cooling systems monobloc
AW15/B-DNNNE, Air-source heat pump, often used in moderate climates, use the difference between outdoor air temperatures and indoor air temperatures to cool and heat your home, at the same time to supply domestic hot water.
HISEER AW15B-DNNNE, galvanized sheet, high efficiency air to water heat pump, 380-415V/3/50Hz, R410a refrigeration, designed and tested by EN14511, approved by TUV china branch, adopt the following world famous parts:
* SWEP or GEA plate type heat exchanger
* Siemens controller
* Daikin scroll compressor
* Schneider A/C contactor
* Emersion thermal expansion valve
* Emersion dry filter
*Soft start is standard part
How does a air source heat pump work?
An air source heat pump is made up of three main components - an evaporator coil, a compressor, and a heat exchanger.
The evaporator coil is fitted to the outside of an external wall. It absorbs heat from the outside air. The compressor pushes the refrigerant gas through the system compressing it until it is at the desired temperature (typically up to 35-40 degrees Celcius). The hot refrigerant then passes through the heat exchanger where the heat from the refrigerant is transferred to water or air.
the operation of a heat pump can be reversed and used to cool down the air in a building by radiating it outside - behaving in exactly the same way as a refrigerator.
Coefficient of performance
ASHPs supply more energy than they consume. By extracting heat from the surrounding air, the heat energy released can be up to 3 times the energy required to power the equipment.
AW15/B-DNNNE technical data
|
AIR TO WATER HEAT PUMP |
AW15/B-DNNNE |
|
|
Heat output/Power consumption at 7/35℃ |
kW |
16.0/4.3 |
|
Heat output/Power consumption at 7/45℃ |
kW |
15.4/5.0 |
|
Heat output/Power consumption at 7/55℃ |
kW |
14.8/6.2 |
|
Heat output/Power consumption at 2/35℃ |
kW |
13.8/4.3 |
|
Heat output/Power consumption at 2/45℃ |
kW |
13.3/5.0 |
|
Heat output/Power consumption at -7/35℃ |
kW |
10.3/4.4 |
|
Heat output/Power consumption at -7/45℃ |
kW |
10.2/5.1 |
|
Cool output/Power consumption at 35/7℃ |
KW |
14.5/5.2 |
|
Starting current |
A |
56 |
|
Power |
380-415V/3PH/50Hz |
|
|
Compressor |
HITACHI scroll |
|
|
Condenser |
Brazed plate heat exchanger |
|
|
Nominal flow heating medium |
l/s |
0.76 |
|
Internal pressure drop at nominal flow |
kPa |
22 |
|
Air flow |
m3/h |
5000 |
|
Nominal output fan |
W |
300 |
|
Max outgoing heating medium temperature |
℃ |
55℃ |
|
Dimensions(H | ||
Send Inquiry to This Supplier
You May Also Like
-
Flow 220 M3/min EI CompressorNegotiableMOQ: 1 Set
-
SCAIR 100HP 0.8MPa Aquaculture Compressor for RAS Oxygenation & Live Fish Transport SystemsNegotiableMOQ: 1 Unit
-
Flow 215 M3/min EI CompressorNegotiableMOQ: 1 Set
-
Flow 210 M3/min EI CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 19000 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 18000 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 13500Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 9000 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 4320 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 2880 Steam CompressorNegotiableMOQ: 1 Set