Best Air to Water Heat Pump Monobloc Used in Moderate Climates
Certification:CE EN14511
Best air to water heat pump monobloc used in moderate climates
AW09-QNNNS, Air-source heat pump, often used in moderate climates, use the difference between outdoor air temperatures and indoor air temperatures to cool and heat your home, at the same time to supply domestic hot water.
HISEER AW09-QNNNS, stainless steel high efficiency air to water heat pump, 220-240V/1/50Hz, R410a refrigeration, designed and tested by EN14511, approved by TUV china branch, adopt the following world famous parts:
* SWEP or GEA plate type heat exchanger
* Siemens controller
* Daikin scroll compressor
* Schneider A/C contactor
* Emersion thermal expansion valve
* Emersion dry filter
*Soft start is standard part
How does a air source heat pump work?
An air source heat pump is made up of three main components - an evaporator coil, a compressor, and a heat exchanger.
The evaporator coil is fitted to the outside of an external wall. It absorbs heat from the outside air. The compressor pushes the refrigerant gas through the system compressing it until it is at the desired temperature (typically up to 35-40 degrees Celcius). The hot refrigerant then passes through the heat exchanger where the heat from the refrigerant is transferred to water or air.
the operation of a heat pump can be reversed and used to cool down the air in a building by radiating it outside - behaving in exactly the same way as a refrigerator.
Coefficient of performance
|
ASHPs supply more energy than they consume. By extracting heat from the surrounding air, the heat energy released can be up to 3 times the energy required to power the equipment. |
|||||||||||||||||||||||||||||||||||||||
|
Heat pumps are measured by their coefficient of performance (COP). The COP for air source heat pumps is very similar to that for ground source heat pumps at approximately 2-3. With a COP for instance of 3, 3 units of heat are produced for every 1 unit of electricity consumed. (The two free units of heating were extracted from the outside air). Even with ambient air temperatures of -10 to -15 degrees Celsius, an air source heat pump can extract useful heat (i.e. > 1 unit of heat generated per unit of electricity consumed).
| |||||||||||||||||||||||||||||||||||||||
Send Inquiry to This Supplier
You May Also Like
-
Swept Volume M3/hr 19000 Steam CompressorNegotiableMOQ: 1 Set
-
SCAIR 100HP 1.2MPa Marine Compressor for Ballast Water UV Sterilization & ElectrochlorinationNegotiableMOQ: 1 Unit
-
Swept Volume M3/hr 18000 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 13500Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 9000 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 4320 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 2880 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 2160 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr 1440 Steam CompressorNegotiableMOQ: 1 Set
-
Swept Volume M3/hr1080Steam CompressorNegotiableMOQ: 1 Set